Inspection
•
Check the pump housing, rotor, idler gear, idler pin and cover for wear and
chipped or broken teeth. There must not be any deep scratches or grooves on the
following:
ID surface of the housing
OD of the rotor
End face of the rotor
OD of the idler
Either face of the idler
Inside surfaces of the cover, including the crescent.
•
Replace worn parts as needed.
•
The rotor should be positioned in the housing or bracket and checked for
clearance in the bearing. The shaft must turn freely without any detectable side
play. Any side play will require replacement of the housing, bracket, rotor or all
three parts.
Assembly of Pump
•
Clean all parts thoroughly using great care to eliminate all dirt.
•
Install the rotor in the pump bracket.
•
Position the selected gaskets over the mounting registers of the bracket and
cover.
Note: Gaskets are supplied with each pump so that proper internal clearances are
maintained. In sizes 2 through 6, composite gaskets are supplied for standard pumping
applications and consist of a steel shim enclosed in a Buna N rubber. Size 1 pumps
utilize paper gaskets. The typical end clearances for these pumps are as follows:
When pumping thinner viscosity fluids, fluids that are not compatible with Buna N, or a
drop-off in capacity has occurred because of excessive end play of the rotor, paper or
plastic shim type gaskets should be used. These are available from Tuthill as spare
parts. The minimum end clearances for proper pump operation are as follows:
Spare part number
1C34.006
2M34.003/.004/.005
3M34.003/.004/.005
5C34.003/.004/.005
Pump size
1
2
3&4
5&6
Clearance
.
003 to .006"
.004 to.009"
.004 to.009"
.007 to .010"
Pump size
1
2
3 & 4
5 & 6
Clearance
.0005 to.001"
.001 to .002"
.002 to .003"
.003 to .005"