background image

E

N

G

L

I

S

H

Operating Instructions  

INDC60ODP

6

Troubleshooting Chart

VES

-Artex

 Industrial Ceiling Fan is tested before it leaves the factory, resulting in an 

 

extremely low rate of returns. However, due to shipping and installation procedures, oc-

casionally a fan will need a minor adjustment to run satisfactorily. If this should 

 

happen, we recommend that you identify the problem and try the simple suggestions 

listed below.

Turn off power at main circuit breaker before checking!

Fan will not start    

a) Check fuses and circuit breakers.

b) Check wire connections to fan.

c) Check wiring connection in lower canopy.

d) Check voltage at fan connection.

_______________________________________________________________________________________________________

___________ 

Fan too fast / slow 

a) Adjust the trim set screw in fan wall control if using optional wall control. If minimum setting

is too low the fan may shut off with voltage fluctuations. Increase minimum.

b) Check voltage at fan connection.

c) Blades must be attached to motor to reduce the speed.

_______________________________________________________________________________________________________

___________ 

 Fan makes noise 

a) Check motor case to make certain all visible screws are snug.

b) Check to make certain that all blade bracket screws are tight.

c) Check for labels or wire nuts that could be rubbing.

d) All ceiling fans may have a slight motor noise known as the “60 cycle hum” when used with

solid state infinite speed controls. Especially on lower speeds. This hum will not affect the

fan performance.

e) Make certain upper canopy is at least 1/8” from ceiling

f) Allow a 30 days break-in period which normally eliminates any Residual noise other than a),

b), c), d) or e).

_______________________________________________________________________________________________________

___________

Fan wobbles 

a)  Check that all blade brackets are screwed firmly to motor case.

b) Check distance from tip of blades to ceiling. If blades get bent during installation, you must

re-adjust them so that all blades travel on same plane. Gently bend up or down until all

distance are the same.

c) Make certain upper canopy is 1/8” from ceiling.

d) Make certain that hanging hooks are secured tightly to ceiling.

e) Run fan without blade, if motor does not wobble, then motor is not defective but the blades

maybe bent.

Symptom 

Corrective Action

Summary of Contents for VES-Artex INDC60ODP

Page 1: ...llow all maintenance procedures enclosed Failure to properly ground unit could result in severe electrical shock or death 1 All wiring should conform to the National Electrical Code in the United Stat...

Page 2: ...lot hole for J hook Put J hook 12 through pilot hole in joist Add flat washer and then lock washer 20 and nut 22 Do not tighten completely until fan is put in place on J hook A lubricant should not be...

Page 3: ...ontroller Control Installation The wall control switch has been investigated and found acceptable for use as a speed control switch Models INDC60ODP Length of downrod is measured as shown above Top of...

Page 4: ...________________________________ ______________________________________________________________________________________ ________________________________________________________________________________...

Page 5: ..._____________________________________________________ ___________ Fan makes noise a Check motor case to make certain all visible screws are snug b Check to make certain that all blade bracket screws a...

Page 6: ...on account of any unauthorized recommendations opinions or advice as to the choice installation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales con...

Page 7: ..._______________________________________________________________________ ________________________________________________________________________________________ _______________________________________...

Reviews: