4 Troubleshooting 

Number 

Failure descriptions 

Analysis and solution 

The mode indicator light does not respond 
or the indication is incorrect.

 

Check that the control panel mode indicator 
wiring is correct or that the contact is poor.

 

After swiping the card, there is only a speed 
gate unlocked.

 

Check the mode setting of the master and 
slave devices and the 8-core, 2-core 
connection lines. See the wiring diagram for 
the specific connection circuit.

 

The barrier doesn’t close when the opening 
delay time is ended.

 

Check to see if the opening delay time is too 
long or whether the IR sensor is covered.

 

When the gate is self-tested, the swing arm 
is not in the normal closing position!

 

In the process of self-test, there are obstacles, 
please remove the obstacles, restart the self-
test after power-on!

 

www.TURNSTILES.us | [email protected] | 303-670-1099

6

Summary of Contents for OTSG9000 Series

Page 1: ...Installation Guide Speed gates OTSG9000 series Applicable Model s OTSG9000 OTSG9011 OTSG9022 OTSG9033 OTSG9200 OTSG9211 OTSG9222 OTSG9233 Version 1 0 Date June 2019...

Page 2: ...onfiguration M12 expansion screws included in the package 3 Thread the connection wire of the device through the tube before assembly 4 The power and signal wires should be set separately to easily di...

Page 3: ...st the operations of the device after connecting it to the power supply with the temporary cable Make sure that the ground wire of AC power is connected to the cabinet of the device 5 Turn on the air...

Page 4: ...ous menu or cancel the current operation Menus 1 Position adjustment of the swing barrier Type zero default Left limit Right limit 2 Passing mode Opening mode Two way swipe default Left free Right swi...

Page 5: ...1 7 Closing speed Speed value 1 20 default 1 8 Swiping mode Method Allow the card to be swiped in the channel default Do not allow card swiping in the channel 9 Reset counter Reset Out counter default...

Page 6: ...d anti pinch Mode Turn off the anti pinch feature Enabling anti pinch default 17 Infrared anti pinch area Area selection Disable during In and out of infrared default All infrared zone anti pinch 18 M...

Page 7: ...and slave devices and the 8 core 2 core connection lines See the wiring diagram for the specific connection circuit 3 The barrier doesn t close when the opening delay time is ended Check to see if th...

Page 8: ...5 Wiring Diagram Below is the wiring diagram Figure 5 1 www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099 7...

Reviews: