User Manual
The Anti-pinch
(incidental pedestrian contact)
Area Setting needs to be
programmed
to (25E001) for the Anti
-
tailgate Setting (27E000) to be effective.
Swing-Barrier
Closing Position (28EXXX)
(28E000) Last pair (default)
(28E001)
Next-to-last
pair
(29E000) Stop (default)
(29E001) Open
(29E002) Close
(30E000) Invalid
(30E001) Effective (default)
Walk-Through Metal Detector Enablement (30EXXX)
When the
OMD22
Walk-Through Metal Detector "Enablement" is programmed for
"INVALID"”, only user authentication (card swiping, phone, biometric) is required to
open the swing-barrier. But if "Enablement" is programmed for "EFFECTIVE” then
DOUBLE VERIFICATION (user authentication PLUS negative metal detection) is
required to open the swing-barrier.
The Anti-pinch
(incidental pedestrian contact)
Area Setting needs to be
programmed
to (25E001) for the
Swing-Barrier
Closing
Position (28E001) to be effective.
Anti-pinch
(incidental pedestrian contact)
Action Setting (29EXXX)
Settings include Stop, Open or Close the
swing-barrier
www.TURNSTILES.us | [email protected] | 303-670-1099