Field Scout Soil EC Meter 

 

 

                   
 
The Field Scout Direct Soil EC probe permits instant, accurate measurement of salts 
directly in the soil as well as water or nutrient solutions. Use this portable EC meter and 
probe to measure soil salinity directly on golf greens, fairways, and athletic fields right on 
the spot, without conducting tedious soil sampling and soil preparation. 
 
You can test different levels in the soil profile with the eight-
inch-long probe.  You can also use the probe to fine-tune your 
fertility program. Measurement can be made directly in the soil 
without pulling soil cores. Turf managers can monitor for high 
salt levels on golf course greens and determine when to flush 
(leach) salts before turf quality declines. Check your water 
quality or nutrient solutions using the same probe. 
 

Resolution 0.01 mS/cm. Accuracy ± 2%. 

Automatic temperature compensation. 

Includes case, calibration standards, and battery. 

 

Field Scout Soil EC Meter - ECM1-N 

Summary of Contents for ECM1-N

Page 1: ...paration You can test different levels in the soil profile with the eight inch long probe You can also use the probe to fine tune your fertility program Measurement can be made directly in the soil wi...

Page 2: ...Use this portable EC meter and probe to measure salinity directly in the soil without tedious soil sampling and preparation Turfgrass managers can monitor for high salt levels on golf course greens an...

Page 3: ...s will allow a representative average to be computed Important Do not touch the sensor tip with your fingers The oils on the skin will affect the probe s measurement accuracy Meter Settings Accessing...

Page 4: ...e upper display shows the current measured temperature reading based on the factory default calibration 5 Dip the tester into a solution of known temperature and allow time for the built in temperatur...

Page 5: ...rior to measurement Prior to calibration the tip of the probe should be cleaned with alcohol The tester will retain one calibration value in each mode conductivity TDS salinity when the instrument is...

Page 6: ...ments at different soil depths you can determine where the salts are concentrated in the soil profile Soil moisture content will significantly influence the measured EC value To ensure accurate measur...

Page 7: ...if needed The sample should have the consistency of a paste with slightly more water than if the media was in a pot and fully irrigated Press On Off button to power up the meter Insert the probe tip...

Page 8: ...ter of the meter opening Be sure that the small O ring sits at the base of the large plastic assembly 6 While holding the assembly in place hand tighten the nut to the strain relief 7 Connect and tigh...

Page 9: ...resolution 0 1 C 0 1 F Temperature accuracy From 0 to 50 C 0 5 C 0 9 F 1 LSD from 50 to 60 C 1 0 C 1 8 F 1 LSD General Display Graphics Dot matrix 80 x 100 pixel Auto off 8 5 minutes from last key pre...

Page 10: ...0 3 1 6 1 3 4 3 2 3 7 0 0 4 1 9 1 4 4 6 2 4 7 3 0 5 2 2 1 5 4 9 2 5 7 6 0 6 2 4 1 6 5 1 2 6 7 8 0 7 2 7 1 7 5 4 2 7 8 1 0 8 3 0 1 8 5 7 2 8 8 4 0 9 3 2 1 9 5 9 2 9 8 6 1 0 3 5 2 0 6 2 3 0 8 9 Table 1...

Page 11: ...transportation prepaid to Turf Tec International after contacting Turf Tec International and receiving a return authorization number Please include a dated proof of purchase with your tool ANY IMPLIE...

Reviews: