Installing
Mounting the device on a mounting surface
12
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5
Installing
NOTE
Suitable mounting accessories and suitable PoE Ethernet cables are available at
n
The equipment shall only be used in an area of not more than pollution degree 2, as defined
in IEC/EN 60664- 1.
n
The special mounting tool TX-M22-TOOL ensures the safe and IP compliant installation of
the devices.
n
The IP67 PoE cable (TXF-M22G-RJ45-5M oder TXF-M22G-M22G-5M) for achieving IP67 pro-
tection can only be used with a mounting surface thickness of 1.5 to 3 mm.
n
The maximum permissible thickness of the mounting surface is 10 mm.
n
The maximum surface roughness of the mounting surface for correct seating of the seal is
120 µm.
5.1
Mounting the device on a mounting surface
Fig. 4: Mounting TXF700
Mount the device directly on the pre-drilled mounting surface or with special mounting
adapters, tube brackets, wall brackets or similar accessories. The maximum tightening
torque for the for the mounting screws is 130 Ncm, for the mounting nut 1000 Ncm.
IP67 applications: Mount the device on the outside of an IP67 housing with appropriate
accessories ( [
11]) e.g. IP67- PoE Ethernet cable TXF-M22G-RJ45-5M or TXF-M22G-
M22G-5M.
Make sure that the seal, which is included in the mounting accessories, is correctly
seated.
Observe IP classification of the accessories according to the corresponding data sheet.