Setting
RFID channels – overview of the commands
164
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.5.3
Command: Read
The
Read
command causes the read/write head to read the data of tags in the detection range.
128 bytes are transferred in a read operation by default. Larger data volumes can be transferred
in fragments. If a particular EPC is entered, the read/write head only reads the appropriate tags.
All other tags in the detection range are ignored in this case.
NOTE
The command code for fast processing with the loop counter is 0x2002 (hex.) or
8194 (dec.).
Request
Loop counter
See description of the output data, [
Command code
0x0002 (hex.), 2 (dec.)
Memory area
See description of the output data, [
Read/write head address
See description of the output data, [
Length of EPC
Enter EPC size in bytes, if a particular tag is to be read. The
EPC must be defined in the write data (start byte: 0). The
function of the length of the EPC depends on the command
used.
0: No entry of an EPC for executing the command. Only one
tag can be located in the detection range of the read/write
head.
> 0: EPC length of the tag to be read if an EPC is present in
the write data.
Start address
Start address of the memory area on the tag to be read
(entry in bytes)
Length
Length of the data to be read in bytes
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data, Byte 0…(size of the
EPC – 1)
EPC of the tag to be protected
Write data,
Byte (size of the EPC)…127
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0002 (hex.), 2 (dec.)
Length
Length of the read data
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
Increases during command execution
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data, Bytes 0…n
Read data