For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1
Intended use
These devices are designed solely for use in industrial areas.
The multiprotocol I/O module 8IOL is an IO-Link master according to IO-Link specification V1.1
and can be can be operated in the three Ethernet protocols PROFINET, Ethernet/IP™ and Mod-
bus TCP. The module detects the bus protocol automatically during the start-up.
The IO-Link master module TBEN-L…-8IOL has eight IO-Link channels. Up to eight IO-Link
sensors or IO hubs with IO-Link can be connected to the M12 sockets. In addition, up to 12 di-
gital sensors can be connected directly it. When using I/O hubs, it is possible to connect up to
128 digital sensors per device.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
3.2
General safety notes
n
The device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
n
The device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
n
The device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.
n
Change the default password of the integrated web server after the first login. Turck recom-
mends using a secure password.