V02.00 | 2021/05
37
7.1.8
Switching on presence sensing mode
In order to use the Continuous presence sensing mode command, the Presence sensing mode
must be activated in the reader. In Continuous presence sensing mode, the readers are auto-
matically switched on as soon as a tag is located in the detection range.
Choose
Basic Setup
Ò
General
Ò
Device Mode
and set the
Presence sensing mode
option.
Fig. 36: Switching on presence sensing mode
The Advanced access level allows the
Tag data delay time
and
Carrier delay time
parameters
to be set individually.
n
Tag data delay time
: Time in which the reader searches for a tag. If a tag is found, the field is
switched on. In the Basic access level, the parameter is set by default to 100 ms.
n
Carrier delay time
: Time until the reader switches off the field after the last read operation.
In the Basic access level, the parameter is set by default to 65535 ms.
NOTE
Report mode is recommended for the RFID test since the read tag information items
appear in the RFID test window and do not have to be polled individually.
Summary of Contents for 100000897
Page 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Reader...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Page 69: ...V02 00 2021 05 69 fclose fh else printf failed on writing n return 1...
Page 75: ...V02 00 2021 05 75 else printf failed on writing n return 1 return EXIT_SUCCESS...
Page 93: ...V02 00 2021 05 93 Select RS485 RFID and confirm with OK Fig 67 Selecting the RS485 interface...
Page 97: ...V02 00 2021 05 97 Click the Select BL File button Fig 73 Button selecting a BL file...