Turbosound Siena TSP118B-AN Quick Start Manual Download Page 8

14

Quick Start Guide

15

TSP-AN Series

Mounting and Fixing 

TSP-AN full-range series cabinets are designed with multiple internal rigging points to suit many possible mounting methods in permanent installations. 

Suspending with Eyebolts 

TSP-AN cabinets can be suspended using optional eyebolts coupled to the internal rigging points provided on the 
top, bottom and sides and back. The simplest method is to use the two rigging points on the top and a single pull-
back rigging point in the centre of the rear panel. 

Remove the appropriate countersunk screws and replace them with shoulder eyebolts, which must have a thread 
length of at least 18 mm. Use the rear rigging point to angle the cabinet for optimum room coverage. Cabinets may 
be hung upside down if required. 

IMPORTANT NOTE:

 The mounting of a permanently installed sound system may be dangerous unless undertaken 

by qualifi ed personnel with the required experience and certifi cation to perform the necessary tasks. Walls, fl oors 
or ceilings must be capable of safely and securely supporting the actual load. The mounting accessory used must be 
safely and securely fi xed both to the loudspeaker and to the wall, fl oor or ceiling.

When mounting rigging components on walls, fl oors or ceilings, ensure that all fi xings and fasteners used are of 
an appropriate size and load rating. Wall and ceiling claddings, and the construction and composition of walls and 
ceilings, all need to be taken into account when determining whether a particular fi xing arrangement can be safely 
employed for a particular load. Cavity plugs or other specialist fi xings, if required, must be of an appropriate type, 
and must be fi tted and used in accordance with the maker’s instructions.

The operation of your speaker cabinet as part of a fl own system, if installed incorrectly and improperly, can potentially expose persons to serious health risks and 
even death. In addition, please ensure that electrical, mechanical and acoustic considerations are discussed with qualifi ed and certifi ed (by local state or national 
authorities) personnel prior to any installation or fl ying.

Make sure that speaker cabinets are set up and fl own by qualifi ed and certifi ed personnel only, using dedicated equipment and original parts and components 
delivered with the unit. If any parts or components are missing please contact your dealer before attempting to set up the system.

Be sure to observe the local, state and other safety regulations applicable in your country. MUSIC Group, including the MUSIC Group companies listed on the enclosed 
“Service Information Sheet”, assumes no liability for any damage or personal injury resulting from improper use, installation or operation of the product. Regular 
checks must be conducted by qualifi ed personnel to ensure that the system remains in a secure and stable condition. Make sure that, where the speaker is fl own, the 
area underneath the speaker is free of human traffi  c. Do not fl y the speaker in areas that can be entered or used by members of the public.

Speakers create a magnetic fi eld, even if not in operation. Therefore, please keep all materials that can be aff ected by such fi elds (discs, computers, monitors, etc) at a 
safe distance. A safe distance is usually between 1 and 2 metres.

Technical Specifi cations

TSP122-AN

TSP152-AN

TSP118B-AN

System

Frequency response

50 Hz – 18 kHz ±3 dB
43 Hz – 20 kHz -10 dB

41 Hz – 18 kHz ±3 dB
35 Hz – 20 kHz -10 dB

35 Hz – 90Hz ±3 dB
32 Hz – 100 Hz -10 dB

Nominal dispersion

70° H x 50° V @ -6 dB Points

70° H x 50° V @ -6 dB Points

Half space

Maximum SPL

133 dB peak

133 dB peak

134 dB peak

Crossover type

Active

Active

Active

Transducers

1 x 12" (316 mm) LF driver
1 x 1" (25.4 mm) HF compression driver

1 x 15" (394 mm) LF driver
1 x 1" (25.4 mm) HF compression driver

1 x 18" (460 mm) LF driver

Limiter

Independent HF, LF, 
peak and rms

Independent HF, LF, 
peak and rms

Independent LF, peak and rms

Amplifi er

Maximum output power*

2500 W

2500 W

3000 W

Type

Class-D

Class-D

Class-D

Protection

Short circuit, thermal

Short circuit, thermal

Short circuit, thermal

Connectors

Input/link

1 x Combo Jack/XLR, 1 x XLR

1 x Combo Jack/XLR, 1 x XLR

1 x Combo Jack/XLR, 1 x XLR

Sensitivity

+4dBu or +14 dBu software switchable

+4dBu or +14 dBu software switchable

+4dBu or +14 dBu software switchable

Input impedance

40 kΩ balanced

40 kΩ balanced

40 kΩ balanced

Maximum input level

+22 dBu

+22 dBu

+22 dBu

Ultranet input/link

2 x RJ45

2 x RJ45

2 x RJ45

Mains supply

Neutrik powerCON 20A†

Neutrik powerCON 20A†

Neutrik powerCON 20A†

Controls

DSP

Rotary push-encoder and level control
Buttons for process, setup, exit, enter

Rotary push-encoder and level control
Buttons for process, setup, exit, enter

Rotary push-encoder and level control
Buttons for Process, Setup, Exit, Enter

User DSP Functions

Factory EQ presets

Positioning, sound mode, FBQ

Positioning, sound mode, FBQ

Positioning, sound mode, FBQ

Display

LCD 128 x 32, blue, backlit

LCD 128 x 32, blue, backlit

LCD 128 x 32, blue, backlit

Delay

0 - 300 ms

0 - 300 ms

0 - 300 ms

Equalisation

High and low shelving EQ
2 x parametric EQ

High and low shelving EQ
2 x parametric EQ

High and low shelving EQ
2 x parametric EQ

Limiter

Zero attack input limiter

Zero attack input limiter

Zero attack input limiter

Presets

20 total presets, 
19 user-defi nable

20 total presets, 
19 user-defi nable

20 total presets, 
19 user-defi nable

Crossover

High pass L-R 24 dB/oct

High pass L-R 24 dB/oct

High pass L-R 24 dB/oct

Protection

Lock-out function for all settings

Lock-out function for all settings

Lock-out function for all settings

Ultranet Digital Network

Digital processing

A/D conversion

24-bit,44.1/48kHz sample rate

24-bit,44.1/48kHz sample rate

24-bit,44.1/48kHz sample rate

Converter type

24-bit,delta-sigma

24-bit,delta-sigma

24-bit,delta-sigma

System

Signal

16 channels

16 channels

16 channels

Latency

< 0.9 ms

< 0.9 ms

< 0.9 ms

Frequency response

20 Hz to 20 kHz (+0 / -3 dB)

20 Hz to 20 kHz (+0 / -3 dB)

20 Hz to 20 kHz (+0 / -3 dB)

Dynamic range

Typical 92 dB

Typical 92 dB

Typical 92 dB

Cabling

Cables

Shielded CAT5

Shielded CAT5

Shielded CAT5

Cable length

Max. 246 ft / 75 m recommended

Max. 246 ft / 75 m recommended

Max. 246 ft / 75 m recommended

Summary of Contents for Siena TSP118B-AN

Page 1: ...Siena TSP AN SERIES TSP122 AN TSP152 AN TSP118B AN 2 500 Watt 2 Way Full Range Powered Loudspeakers 3000 Watt Powered Subwoofer KLARK TEKNIK DSP Technology and ULTRANET Networking...

Page 2: ...es mbolo siemprequeaparece leadviertedelapresenciadevoltaje peligrososinaislardentrodelacaja estevoltajepuedesersuficienteparaconstituirunriesgo dedescarga Estes mbolo siemprequeaparece leadviertesobr...

Page 3: ...Pourconna trelestermesetconditionsdegarantie applicables ainsiquelesinformationssuppl mentaires etd taill essurlaGarantieLimit edeMUSICGroup consultezlesiteInternetmusic group com warranty Vorsicht Di...

Page 4: ...a especificadospelo fabricanteouvendidos comodispositivo Quandoutilizarum carrinho tenhacuidadoao moveroconjuntocarrinho dispositivoparaevitardanos provocadospelaterpida o 15 Desligueestedispositivodu...

Page 5: ...ker After unpacking the unit please check carefully for damage If damage is found please notify your supplier at once You the consignee must instigate any claim Please retain all packaging in case of...

Page 6: ...INK XLR connector provides an un processed copy of the AUDIO INPUT signal 11 AUDIO INPUT combo jack accepts input signals using XLR balanced TRS or unbalanced TS connectors 12 POWER switch turns the u...

Page 7: ...eaker on a pole mount stand fullrange or on the floor subwoofer Fullrange Subwoofer Function Wall Wall For positioning the speaker on or next to a wall fixed install alternatively as a monitor speaker...

Page 8: ...peaker in areas that can be entered or used by members of the public Speakers create a magnetic field even if not in operation Therefore please keep all materials that can be affected by such fields d...

Page 9: ...max power 180 W 1 8 max power Voltage fuses USA Canada 120 V 60 Hz T 15 A H 250 V 120 V 60 Hz T 15 A H 250 V 120 V 60 Hz T 15 A H 250 V UK Australia Europe 220 240 V 50 60 Hz T 10 A H 250 V 220 240 V...

Page 10: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio f...

Page 11: ......

Reviews: