14
Quick Start Guide
15
TSP-AN Series
Mounting and Fixing
TSP-AN full-range series cabinets are designed with multiple internal rigging points to suit many possible mounting methods in permanent installations.
Suspending with Eyebolts
TSP-AN cabinets can be suspended using optional eyebolts coupled to the internal rigging points provided on the
top, bottom and sides and back. The simplest method is to use the two rigging points on the top and a single pull-
back rigging point in the centre of the rear panel.
Remove the appropriate countersunk screws and replace them with shoulder eyebolts, which must have a thread
length of at least 18 mm. Use the rear rigging point to angle the cabinet for optimum room coverage. Cabinets may
be hung upside down if required.
IMPORTANT NOTE:
The mounting of a permanently installed sound system may be dangerous unless undertaken
by qualifi ed personnel with the required experience and certifi cation to perform the necessary tasks. Walls, fl oors
or ceilings must be capable of safely and securely supporting the actual load. The mounting accessory used must be
safely and securely fi xed both to the loudspeaker and to the wall, fl oor or ceiling.
When mounting rigging components on walls, fl oors or ceilings, ensure that all fi xings and fasteners used are of
an appropriate size and load rating. Wall and ceiling claddings, and the construction and composition of walls and
ceilings, all need to be taken into account when determining whether a particular fi xing arrangement can be safely
employed for a particular load. Cavity plugs or other specialist fi xings, if required, must be of an appropriate type,
and must be fi tted and used in accordance with the maker’s instructions.
The operation of your speaker cabinet as part of a fl own system, if installed incorrectly and improperly, can potentially expose persons to serious health risks and
even death. In addition, please ensure that electrical, mechanical and acoustic considerations are discussed with qualifi ed and certifi ed (by local state or national
authorities) personnel prior to any installation or fl ying.
Make sure that speaker cabinets are set up and fl own by qualifi ed and certifi ed personnel only, using dedicated equipment and original parts and components
delivered with the unit. If any parts or components are missing please contact your dealer before attempting to set up the system.
Be sure to observe the local, state and other safety regulations applicable in your country. MUSIC Group, including the MUSIC Group companies listed on the enclosed
“Service Information Sheet”, assumes no liability for any damage or personal injury resulting from improper use, installation or operation of the product. Regular
checks must be conducted by qualifi ed personnel to ensure that the system remains in a secure and stable condition. Make sure that, where the speaker is fl own, the
area underneath the speaker is free of human traffi c. Do not fl y the speaker in areas that can be entered or used by members of the public.
Speakers create a magnetic fi eld, even if not in operation. Therefore, please keep all materials that can be aff ected by such fi elds (discs, computers, monitors, etc) at a
safe distance. A safe distance is usually between 1 and 2 metres.
Technical Specifi cations
TSP122-AN
TSP152-AN
TSP118B-AN
System
Frequency response
50 Hz – 18 kHz ±3 dB
43 Hz – 20 kHz -10 dB
41 Hz – 18 kHz ±3 dB
35 Hz – 20 kHz -10 dB
35 Hz – 90Hz ±3 dB
32 Hz – 100 Hz -10 dB
Nominal dispersion
70° H x 50° V @ -6 dB Points
70° H x 50° V @ -6 dB Points
Half space
Maximum SPL
133 dB peak
133 dB peak
134 dB peak
Crossover type
Active
Active
Active
Transducers
1 x 12" (316 mm) LF driver
1 x 1" (25.4 mm) HF compression driver
1 x 15" (394 mm) LF driver
1 x 1" (25.4 mm) HF compression driver
1 x 18" (460 mm) LF driver
Limiter
Independent HF, LF,
peak and rms
Independent HF, LF,
peak and rms
Independent LF, peak and rms
Amplifi er
Maximum output power*
2500 W
2500 W
3000 W
Type
Class-D
Class-D
Class-D
Protection
Short circuit, thermal
Short circuit, thermal
Short circuit, thermal
Connectors
Input/link
1 x Combo Jack/XLR, 1 x XLR
1 x Combo Jack/XLR, 1 x XLR
1 x Combo Jack/XLR, 1 x XLR
Sensitivity
+4dBu or +14 dBu software switchable
+4dBu or +14 dBu software switchable
+4dBu or +14 dBu software switchable
Input impedance
40 kΩ balanced
40 kΩ balanced
40 kΩ balanced
Maximum input level
+22 dBu
+22 dBu
+22 dBu
Ultranet input/link
2 x RJ45
2 x RJ45
2 x RJ45
Mains supply
Neutrik powerCON 20A†
Neutrik powerCON 20A†
Neutrik powerCON 20A†
Controls
DSP
Rotary push-encoder and level control
Buttons for process, setup, exit, enter
Rotary push-encoder and level control
Buttons for process, setup, exit, enter
Rotary push-encoder and level control
Buttons for Process, Setup, Exit, Enter
User DSP Functions
Factory EQ presets
Positioning, sound mode, FBQ
Positioning, sound mode, FBQ
Positioning, sound mode, FBQ
Display
LCD 128 x 32, blue, backlit
LCD 128 x 32, blue, backlit
LCD 128 x 32, blue, backlit
Delay
0 - 300 ms
0 - 300 ms
0 - 300 ms
Equalisation
High and low shelving EQ
2 x parametric EQ
High and low shelving EQ
2 x parametric EQ
High and low shelving EQ
2 x parametric EQ
Limiter
Zero attack input limiter
Zero attack input limiter
Zero attack input limiter
Presets
20 total presets,
19 user-defi nable
20 total presets,
19 user-defi nable
20 total presets,
19 user-defi nable
Crossover
High pass L-R 24 dB/oct
High pass L-R 24 dB/oct
High pass L-R 24 dB/oct
Protection
Lock-out function for all settings
Lock-out function for all settings
Lock-out function for all settings
Ultranet Digital Network
Digital processing
A/D conversion
24-bit,44.1/48kHz sample rate
24-bit,44.1/48kHz sample rate
24-bit,44.1/48kHz sample rate
Converter type
24-bit,delta-sigma
24-bit,delta-sigma
24-bit,delta-sigma
System
Signal
16 channels
16 channels
16 channels
Latency
< 0.9 ms
< 0.9 ms
< 0.9 ms
Frequency response
20 Hz to 20 kHz (+0 / -3 dB)
20 Hz to 20 kHz (+0 / -3 dB)
20 Hz to 20 kHz (+0 / -3 dB)
Dynamic range
Typical 92 dB
Typical 92 dB
Typical 92 dB
Cabling
Cables
Shielded CAT5
Shielded CAT5
Shielded CAT5
Cable length
Max. 246 ft / 75 m recommended
Max. 246 ft / 75 m recommended
Max. 246 ft / 75 m recommended
Summary of Contents for Siena TSP118B-AN