OUTLET

INLET

Figure 2 

- KWM11

Piping

•  The piping on the unit will usually be copper or any other 

locally approved piping. Accessible ½” sweat fittings are 

provided on the unit itself. An optional flexible stainless 

steel connector kit with shut-off valves is available for 

connecting the unit to any type of piping system and can 

be used with an optional valve control box.

•  All piping systems should be designed by a technician 

with experience in the various piping arrangements that 

work with this type of unit.

•  As with any system employing circulated water, the pipes 

passing through unheated spaces should be insulated.

NOTE: When using mono-flo or “venturi” fittings, we 
suggest placement of a ball valve just after the supply 
take-off and before the return is connected.

Piping: Hot Water Boiler

•  The unit supply line should be taken from the boiler side 

beyond any flo-control valve. If the system being used is 

a gravity-flow or cast iron hot water system, a separate 

circuit must be installed.

Piping: Water Heater

•  To install correctly, a technician with knowledge of piping 

arrangements and back-flo valves must design the piping 

system.

Wiring the Unit

•  A field wiring connection is provided on the unit (see 

figure 5). Connect wires at this point only.

•  The unit is manufactured with a built-in factory wired 

aquastat with a set point of 140°F on and 110°F off. The 

aquastat may be disabled in the field if not required (see 

application manuals).

Summary of Contents for KWM6

Page 1: ... 21 32 347mm 13 5 32 334mm 19 32 15mm 4 19 32 117mm 3 15 32 88mm WIRING INPUT INLET 1 2 COPPER TUBING OUTLET 1 2 COPPER TUBING CAT 09853 TUR Figure 1 KWM6 Unit is designed to be mounted under sheetrock for proper fit of the cover Install at least 6 8 above the floor for best performance Unit will fit between standard 16 studs on center For unit dimensions on the KWM6 refer to Figure 1 3 6 For KWM1...

Page 2: ... NOTE When using mono flo or venturi fittings we suggest placement of a ball valve just after the supply take off and before the return is connected Piping Hot Water Boiler The unit supply line should be taken from the boiler side beyond any flo control valve If the system being used is a gravity flow or cast iron hot water system a separate circuit must be installed Piping Water Heater To install...

Page 3: ... 10 32 X 1 2 SCREW NYLON WASHER INCLUDED KWM6 RECESSED COVER KWM6 UNIT CAT 09853 TUR KWM11 UNIT KWM11 RECESSED COVER 4X 10 32 X 1 2 SCREW AND NYLON WASHER INCLUDED CAT 09853 TUR 4X 10 32 X 1 2 SCREW NYLON WASHER INCLUDED KWM11 RECESSED COVER KWM11 UNIT CAT 09853 TUR Figure 3 KWM6 Figure 4 KWM11 ...

Page 4: ...Z LINE FUSED CIRCUIT ONLY 120V 60Hz LINE WHITE WHITE BLACK GREEN GROUND SCREW YELLOW HEYCO YELLOW GREEN BLACK 2 SPEED SWITCH RED WHITE 2 1 OFF BLACK WHITE AQUASTAT AQUASTAT STANDARD WIRING STANDARD WIRING WITH AQUASTAT DISABLE IMPENDENCE PROTECTED 2 SPEED 2P MOTOR HEAVY DUTY BEARINGS FROM FIELD 120V 60HZ LINE FUSED CIRCUIT ONLY NOTE ALL WIRING SHALL MEET ALL LOCAL AND NATIONAL CODE 15 00 4 06 2 50...

Reviews: