Special Manual Operating Mode
In the basic set up men, first menu item, select Special mode, enter the pulse
time and pause time. Open the advanced set up menu, second menu item, enter
the number of complete cycles and pause time between these cycles for the
connected solenoid valves.
With this mode, unlike manual mode, the device only runs the solenoid valves for
the set number of cycles and will remain in stand-by until an operator presses
S
(start / stop) in the main menu to repeat the cycles. This mode is especially
suited for small filters or filters where the dP has low values or the inverter
keeps pressure constant and it is hard to work with automatic and proportional
modes.
Other Function Descriptions
Alarms
This function allows an alarm device to be connected. The alarm device can be
connected to two alarm relays (see wiring diagram) which are opened when the
threshold set in the ALARMS menu is exceeded. For details, see the third menu
item and the description in the Accessing the Alarm menu section.
When an alarm is triggered, it is signaled on the display by a blinking row that is
normally occupied by the operating mode. The menu key is used for Reset and
keys
can be used to scroll any alarm items that may have triggered for
relay no. 1: dP minimum (
if enabled in the menu
), dP Dirty Filter, Replace Filters
(if enabled in the menu) while failed valve activation is signaled with relay no. 2.
Rel ay 1
Termi nals 8-9 Conn. P4
Rel ay 2
Termi nals 6-7 Conn. P4
Rel ay 3
Termi nals 4-5 Conn. P4
dP Minimum
if enabled in the menu
Valve Activation Failed
Triboelectric Probe
Pre - Alarm
dP Dirty Filter
Triboelectric Probe
Alarm
Replace Filters
if enabled in the menu
Triboelectric Probe
Peak