background image

www.turbo-e.com

INSTRUCTION MANUAL

Lithium Series

 

Dual 48V 5.1kWh

10

YEARS

TURBO ENERGY

WARRANTY

  LONG-LASTING LITHIUM-ION BATTERIES

  MAXIMUM CUSTOMER SATISFACTION

  PLUG & PLAY

  PARALLEL/SERIES CONNECTION

Summary of Contents for Lithium Dual 48V 5.1kWh Series

Page 1: ...www turbo e com INSTRUCTION MANUAL Lithium Series Dual 48V 5 1kWh 10 YEARS TURBO ENERGY WARRANTY LONG LASTING LITHIUM ION BATTERIES MAXIMUM CUSTOMER SATISFACTION PLUG PLAY PARALLEL SERIES CONNECTION...

Page 2: ...tions 3 3 Battery Dimensions 4 4 Features 4 5 Operation 5 5 1 Battery elements 5 5 2 Assembly and connection 6 5 2 1 Parallel connection 6 5 2 2 Serie connection 8 5 2 3 Configuration without communic...

Page 3: ...h of Discharge DoD 90 Nominal Voltage 51 2 V Voltage operating range 48 56 V Connection type Series Parallel Cycle Life 6000 Physical Weight 45 kg Dimensions 500 442 135 mm Protection class IP20 Batte...

Page 4: ...BMS system built into the battery that monitors its operation and does not allow it to work outside the bounds of the design regime V I Expandability The system s accumulation capacity can be expanded...

Page 5: ...onnection 3 SW3 Switch for battery s address 4 SW4 SW5 Communication interface for battery or master battery 5 Reset Restablecer la configuraci n del m dulo WIFI The standard packing list of Lithium S...

Page 6: ...t the same point as all battery lands Connection between batteries Up to 8 batteries are allowed to be used in parallel The batteries used in parallel must be the same batch of cases with the same SOC...

Page 7: ...damage the system As an alternative to balancing voltages balancingcanbedonebyequalizingtheSOCofthebatteries Inaddition whenconnecting new batteries we must take into account that the number of batter...

Page 8: ...he installation ground to the rack at the same point as all battery lands Connection between batteries Up to 8 batteries are allowed to be used in series The batteries used in series must be the same...

Page 9: ...of pole to later assemble the one we need to install We well require a M5 HEX wrench a flat head screwdriver optional and both cables The proccess will be described in the followen steps 1 Unlock the...

Page 10: ...bles once we have interchanged the head of the cables following the previous steps inversely 5 2 3 CONFIGURATION WITHOUT COMMUNICATIONS For those cases where the battery is intended to operate connect...

Page 11: ...ust be ON If 485 protocol is used 3 and 4 must be ON SW4 and SW5 work to communicate with the inverter and depend on the communication cable and the inverter protocol If using a pin to pin cable the D...

Page 12: ...8 9 0 2 Primary 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 3 Primary 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub1 1 5 2 6 3...

Page 13: ...6 7 8 9 0 Sub3 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub4 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 6 Primary 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub1 1 5 2 6...

Page 14: ...4 5 6 7 8 9 0 Sub1 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub2 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub3 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub4 1 5 2 6 3...

Page 15: ...2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Sub6 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 78 9 0 Sub7 1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8 1 2 3 4 5 6 7 8 9 0 Please make sure the SW2 DIP switch is selected correct...

Page 16: ...battery in a cool dry place 9 Never expose the battery to fire or water 8 2 SAFETY WARNINGS 1 Do not disassemble the batteries The inside of the battery has a protective mechanism and a protective cir...

Page 17: ...Under temperature of 20 C 45 C and relative humidity of 45 85 3 months Under temperature of 20 C 35 Cand relative humidity of 45 85 6 months and more Under temperature of 20 C 25 C and relative humid...

Reviews: