background image

3

INSTALLATION OF CASTERS

INSTALLATION OF DRAIN PAN

1) In damp season, when the drain water overflow the drain pan, remove the 
  drain pan and pour the water away. And then set the drain pan back up as
  below drawing please (Model : TWR-28SD-D2, TWF-28SD-D2).

1) Screw the caster (in rear side) and the caster brakes (in front side) by using
 caster 

wrench.

2) Use the caster shims to level the cabinet, if necessary, by inserting them to 
  stems of the casters.

ROTATION

CASTER (2EA)

CASTER (WITH BRAKE)(2EA)

Summary of Contents for TWF-28SD-D2

Page 1: ... and Operation Manual Please read this manual completely before attempting to install or operate this equipment REFRIGERATORS TWR 28SD D2 TWR 48SD D2 TWR 48SD D4 TWR 60SD D2 TWR 60SD D2 FREEZERS TWF 28SD D2 TWF 48SD D2 TWF 48SD D4 www turboairinc com Full Stainless Steel Visible Exterior ...

Page 2: ...ION 7 BASIC OPERATION 8 TROUBLESHOOTING 9 WARRANTY 10 11 STAINLESS STEEL EQUIPMENT CARE AND CLEANING 11 13 REFRIGERATOR MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TWR 48SD D2 1 3 115V 60Hz R 134A 6 5A 264lbs TWR 48SD D4 1 3 115V 60Hz R 134A 6 5A 271lbs TWR 28SD D2 1 4 115V 60Hz R 134A 6 6A 180lbs TWR 60SD D4 1 3 115V 60Hz R 134A 9 9A 312lbs TWR 60SD D2 1 3 115V 60Hz R 134A 8 9A 299lbs FREEZER MOD...

Page 3: ...pour the water away And then set the drain pan back up as below drawing please Model TWR 28SD D2 TWF 28SD D2 1 Screw the caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ROTATION CASTER 2EA CASTER WITH BRAKE 2EA ...

Page 4: ...ch drawer accommodates 4 1 6 size L 67 8 x W 61 4 x H 4 and 8 Food pan sold seperately 3 60 SERIES Each drawer accommodates 6 1 6 size L 67 8 x W 61 4 x H 4 and 8 Food pan sold seperately Fully extend the drawer out toward you as pictured After full extension lift the drawer up and pull towards you This will disengage the rollers from the roller guide ...

Page 5: ...re to install this unit indoor So it should prohibit getting wet from the rain 5 STABILIZING Make sure the unit is installed in a stable condition with the front wheels locked while in use 6 LEVELING Be sure that the unit is level from front to back and side to side 7 UNIT SHOULD BE ON DEDICATED OUTLET 1 CLEANING THE INTERIOR AND EXTERIOR The interior and exterior of the unit can be cleaned using ...

Page 6: ...essor warranties are void if compressor burns out due to low voltage 2 RE STARTING If disconnected wait 5 minutes before re starting 1 The controller thermostat is located at the right inside of the unit 2 The factory setting for the control is Normal 3 Set toward Cool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s on off by sensing inside temperature ...

Page 7: ...tly The backside of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy seasons The door is opened too frequently or left open too long Damp food is stored The door is bent The unit is not level The door gasket has come out Turn the temperature dial to a warmer colder setting Check the power cord to make sure the unit is plu...

Page 8: ...ater Household and industrial cleaners are the worst type of chlorides to use 8 step that can help prevent rust on stainless steel 1 Using the correct cleaning tools Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic scouring pads Step 2 tells you how to find the polishing marks 2 Cleaning along the p...

Page 9: ...ter to wipe standing cleaning agents and water as soon as possible Allow the stainless steel equipment to air dry Oxygen helps maintain the passivity film on stainless steel 7 Hydrochloric acid muriatic acid should never be used on stainless steel 8 Regularly restore passivate stainless steel Recommended cleaners for certain situation environments of stainless steel A Soap ammonia and detergent me...

Page 10: ...after shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Airʼs option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The two 2 year extended compressor warranty applies only to hermetically and semi hermetically sealed parts of the compressor and does not apply to any...

Page 11: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE THREE 3 YEAR WARRANTY AND THE ADDITIONAL TWO 2 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIE...

Page 12: ... lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction drier and 620 dri...