Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be  free

from defects in material or workmanship, under normal use and service, for a period of three (3) year from the date of original
installation or 39 months after shipment date from Turbo Air , whichever occurs first.

Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within three (3) year of

original installation or thirty nine (39) months after shipment date from manufacturer, whichever occurs first, shall be repaired or
replaced as stated below. Turbo Air shall be deemed to have fully complied with its obligation under the foregoing warranties by
electing either one of the following procedures, at the sole discretion of Turbo Air.

1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect.
2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect.

In addition to the three (3) year warranty stated above, Turbo Air warrants its hermetically and semi-hermetically sealed

compressor to be free from defects in both material and workmanship under normal use and service for a period of two (2)
additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from
manufacturer.

Compressors determined by Turbo Air have been defective within this extended time period will, at Turbo Airʼs option, be either

repaired or replaced with a compressor or compressor parts of similar design and capacity.

The two (2) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the

compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature
control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera.

The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing

qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below
are the approved lubricants for the Tecumseh compressors.

1 ICI-Emkarate RL 184
2 Emery-2927-A
3 Mobile Artic 22A

Failure to comply with recommended lubricant specification will void the compressor warranty.

2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH-

9 desiccant.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained.

MANUFACTURING COMPANY

THREE YEAR WARRANTY

ADDITIONAL TWO YEAR COMPRESSOR WARRANTY

134A(404A) COMPRESSOR WARRANTY

Summary of Contents for TST-28SD

Page 1: ...ables Sandwich Salad Units Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment TST 28SD TST 36SD TST 48SD TST 60SD TST 72SD www...

Page 2: ...R 134A 9 9A 372lbs TST 60SD 1 2 115V 60Hz R 134A 8 9A 316lbs The serial number is located on the rating label which is on the left interior wall Please retain the unit s serial number for service purp...

Page 3: ...crew the caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ROTATION CAST...

Page 4: ...the water away And then set the drain pan back up as below drawing please Model TST 28SD TST 28SD 12 TUR 28SD 2 When the drain pan install on the compressor mounted base lift up the vaporizing pipe a...

Page 5: ...5 HOW TO CLEAN THE PAN SUPPORTER 1 Remove the Guide Pans and Pans Then pull out the Pan Supporter Clean the pan supporter and reinstall in place...

Page 6: ...strong enough to support the total weight of the cabinet and contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cool...

Page 7: ...RE STARTING If disconnected wait 5 minutes before re starting Before cleaning turn unit off at power switch 1 CLEANING THE INTERIOR AND EXTERIOR The interior and exterior of the unit can be cleaned us...

Page 8: ...ool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s on off by sensing inside temperature REFRIGERATORS COLD OFF NORMAL COOL TUR 28SD TUF 28SD COLD OFF NORM...

Page 9: ...ly The backside of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy seasons The door is opened too frequently or left open...

Page 10: ...ter Household and industrial cleaners are the worst type of chlorides to use 8 step that can help prevent rust on stainless steel 1 Using the correct cleaning tools Use non abrasive tools when cleanin...

Page 11: ...er to wipe standing cleaning agents and water as soon as possible Allow the stainless steel equipment to air dry Oxygen helps maintain the passivity film on stainless steel 7 Hydrochloric acid muriati...

Page 12: ...fter shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or...

Page 13: ...se accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED...

Page 14: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: