CONDENSER COIL
Condenser coil is located at bottom behind panel.
1.Unplug the power cord.
2.Press pushlocks,located 10mm inside
from each end of the front cover
simultaneously.
3.Hold both ends of front cover and lift
it up slightly.then the front cover will
be disassembled.
4.Brush off all dirt, from the finned
condenser coil.
5.After cleaning, place, reassemble in reverse order of disassembly.
(no3->no.1)
6. Plug in the power cord.
7.Condenser must be cleaned every month.if not,it can be a cause of trouble
or defect.
7
TROUBLE SHOOTING
For any problems with Display please refer to the following check
list. If still having a problem or need to ask a question please call
Customer service at 1-800-381-7770.
LETTERS DF ON DISPLAY
This is normal. On display a green light comes on. Defrost is for
20 minutes. The letters on the display disappear and then there
is a five minute pause. Light blinks then compressor comes on.
When compressor comes on light stops blinking and stays on
DISPLAY NOT WORKING
a. Check power going to unit.
b. Check power switch is on.
DISPLAY CASE WARM
a.Check condenser to see if clean
b.Check that air flow inside of unit is not blocked with product.
LIGHTS NOT WORKING
a.Check that light switch is on.
b.Check that light is in lamp holder correctly.
8