background image

Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be free

from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original
installation or 27 months after shipment date from Turbo Air , whichever occurs first.

Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within two (2) year of

original installation or twenty seven (27) months after shipment date from manufacturer, whichever occurs first, shall be 
repaired or replaced as stated below. Turbo Air shall be deemed to have fully complied with its obligation under the foregoing 
warranties by electing either one of the following procedures, at the sole discretion of Turbo Air.

1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect.
2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect.

In addition to the (2) two year warranty stated above, Turbo Air warrants its hermetically and semi-hermetically sealed

compressor to be free from defects in both material and workmanship under normal use and service for a period of three (3)
additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from
manufacturer.

Compressors determined by Turbo Air have been defective within this extended time period will, at Turbo Airʼs option, be either

repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the

compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature
control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera.

The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing

qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below
are the approved lubricants for the Tecumseh compressors.

1 ICI-Emkarate RL 184
2 Emery-2927-A
3 Mobile Artic 22A

Failure to comply with recommended lubricant specification will void the compressor warranty.

2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH-

9 desiccant.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained.

MANUFACTURING COMPANY

TWO YEAR WARRANTY

ADDITIONAL THREE YEAR COMPRESSOR WARRANTY

134A(404A) COMPRESSOR WARRANTY

Summary of Contents for TGM-69R

Page 1: ...is manual completely before attempting to install or operate this equipment TGM 69R www turboairinc com FEATURE CHART GLASS DOOR BOTTOM GRILL ADJUSTABLE FOOT DOOR HANDLE ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN EVAPORATOR SHELF CONDENSER DRAIN PAN COMPRESSOR INNER DRAIN PAN FLOURESCENT LAMP E D I S T N O R F ...

Page 2: ...ing can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to drain the water away with easily Put away heat source from the refrigerator High ambient temperature will make cooling efficiency lower Place the refrigerator in an area with low moisture Splashing water or a high moisture area may cause short circuit and make rusting ...

Page 3: ...er cord with wet hands Check the noise or overheating Compressor Condenser should be cleaned every 3 months or as needed unit will not cool properly if dirty Especially be sure to clean the condenser before reoperating after a long period of non operation Caution Unplug the power cord before cleaning Clean the refrigerator periodically Do not use the abrasive cleaners solvents or polishing agents ...

Page 4: ...ller should be on normal position If disconnected shut down wait 5 minutes before re starting it Warning It is the responsibility of the purchaser in case of followings Compressor under low voltage Compressor more than 7 feet from plug in connection Compressor under unstable voltage Compressor not under 115V 60Hz Temperature control To keep the temperature down Turn the dial CW To keep the tempera...

Page 5: ...g sound can be heard when the compressor stops This is a sound of REFRIGERANT flowing Because of the differences between ambient temperature and a quantity of food stored when the temp dial is on the cold position Food would freeze in ambient temperature of below 41 F and the temp dial on the cold position When there is a power connection or failure problem When the refrigerator is in sunlight or ...

Page 6: ...er shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Airʼs option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The three 3 year extended compressor warranty applies only to hermetically and semi hermetically sealed parts of the compressor and does not apply to any ...

Page 7: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE TWO 2 YEAR WARRANTY AND THE ADDITIONAL THREE 3 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLI...

Page 8: ... lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction drier and 620 dri...

Reviews: