background image

Warranty Claims...

All claims for parts or labor must be made directly thorough Turbo Air.

All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all

pertinent information supporting the alleged defect.

In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with

above listed information.

Failure to comply with warranty policies will result in voiding claims.

Two Year Parts & Labor Warranty...

Turbo Air warrants all new refrigerated components, the cabinet and all parts, to be free from defects in materials or workmanship,

under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start-up in

accordance with the instruction packet supplied with each Turbo air unit. Turbo Airʼs obligation under this warranty is limited to a period

of two (2) year from the date of original installation or 27 months after shipment date from Turbo Air, whichever occurs first.

Any part, covered under this warranty, that are by Turbo Air to have been defective within two (2) year of original installatio n or twenty seven

(27) months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor

charges, of defective parts or assemblies. The labor warranty shall include standard straight time labor charges only and reasonable

travel time, as determined by Turbo Air.

Additional Three Year Compressor Warranty...

In addition to the two (2) year warranty stated adove, Turbo Air warrants its hermetically sealed compressor to be free from de fects in

both material and workmanship under normal and proper use and maintenance service for a period of three (3) additional years from

the date of original installation, but not to exceed five (5) years and three(3) months after shipment from the manufacturer.

Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Airʼs discretion, be either

repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any

other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers,

motor starting equipment, fan assembly or and other electrical components, etcetera.

404A / 134a Compressor Warranty...

The five-year compressor warranty detailed above will be void if the following procedure is not carefully adhered to:

1. This system contains R404A or R134a refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing

qualities.

2. Drier replacement is very important and must be changed when a system is opened for servicing. A620 copper drier or better is

highly recommended.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.

4. When compressor is grounded, suction drier and 620 drier or better must be replaced.

5. Compressor must be obtained through Turbo Air, unless otherwise specified in writing, through Turbo Airʼs warranty department.

404A / 134a Compressor Warranty...

Turbo Airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations

below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this

warranty.

NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL,

INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES, OR DAMAGES ARISING FROM

FOOD OR PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE.

WARRANTY IS NOT TRANSFERABLE, This warranty is not assignable and applies only in favor of the original purchaser/user to

whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANNTIES HEREIN AND SHALL VOID ALL

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR

COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT.

ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FOOD, ACTS

OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after

the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of GOD.

IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF

FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS,

LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE; THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE TWO

(2) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL THREE (3) YEAR COMPRESSOR WARRANTY AS DESCRIBED

ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY

AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES, WHICH EXTEND

BEYOND THE DESCRIPTION ON THE FACE HEREOF.

Outside U.S.and Canada; This warranty does not apply to, and Turbo Air is not responsible for, any warranty claims made on products

sold or used outside the continent of the United States and Canada.

New Extended Warranty policy applies to all units sold by Turbo Air starting Dec.1, 2012

Summary of Contents for TD-4R

Page 1: ...s Deli Cases Installation and Operation Manual CAUTION PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting to install or operate this equip...

Page 2: ...HTS 4 SHELVES 4 ELECTRICAL INFORMATION 5 WIRING DIAGRAM 6 7 OPERATING INSTRUCTIONS 8 9 FRONT CURVED GLASS 10 MAINTENANCE CLEANING 11 12 TROUBLE SHOOTING 13 WARRANTY MODEL COMP H P V Hz REFRIGERANT AMP...

Page 3: ...nce 86 inch at the top 20 inch at the rear and 12 inch at the cash inside CAUTION Damage to case and glass can result if pushed on Do not push curved glass end glass doors or door frames Do not place...

Page 4: ...gs for lamp holders are completely plugged in If they are loose it may cause lamp holder to burn To install shelves in desired position front glass must be open and rear doors removed Where shelf heig...

Page 5: ...ician Electrical data is located next to electrical junction box see drawing The Deli Case comes with a power cord Cord is 9 8 feet long The plug is a Improper electrical connections can result in ser...

Page 6: ...6 WIRING DIAGRAM TD 4R TD 5R...

Page 7: ...7 WIRING DIAGRAM TD 4 TD 5...

Page 8: ...TROLS 5 The thermostat controls compressor s on off by sensing inside temperature THERMOMETER Display changes temperature approximately every two second NOTE Before placing goods to Bakery Case wait f...

Page 9: ...light not work To remove light there is two lamp holders one at each end of light One has a spring in socket Push light toward spring loaded lamp holder till other end of light pops out of other lamp...

Page 10: ...trained personnel should lift curved glass Under normal use hinges will last many years If any of the following problems occur please call Customer Service a Front curved glass closed rapidly b Front...

Page 11: ...edure may have to be done more than once a week if necessary 1 Clean front glass with window cleaner 2 Clean exterior with warm soapy water Wipe down with damp cloth 1 Remove both doors by lifting up...

Page 12: ...brush or vacuuming with wet dry vacuum Condenser is black and looks like a radiator This should be cleaned every month or as necessary Keeping clean allows for maximum cooling of unit and long life of...

Page 13: ...operate in an ambient temperature of 75 degrees Fahrenheit and 55 relative humidity 4 Check temperature of Deli Case Unit should be between 38 and 42 degrees 5 Check that air is flowing inside front...

Page 14: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Page 15: ...isuse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPL...

Page 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...