Turbo Air TAS-36EHU Owner'S Manual Download Page 8

NOTE: This manual does not include Remote Controller Operations, see the 
<<Remote Controller Instruction>> packed with the unit for details. 

Operating temperature

7

7

Manul operation can be used temporarily in case the remote controller is disable or
maintenance necessary.

OPERATING INSTRUCTIONS

Manual operation

Manual control 

button

Front panel

AUTO/COOL

Open and lift the front panel up to an angle 
until it remains fixed  with a clicking sound.
One press of the manual control button will 
lead to the forced AUTO operation. If press
the button twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original 
position.

This button is used for testing purposes 
only. You had better not choose it.
To restore the remote controller operation, 
use the remote controller directly.

CAUTION:

1

3

2

NOTE:

 The unit must be turned off before

operating the manual control button. If the 
unit is operational, continue pressing the 
manual control button until the unit is off.

Mode

Temperature
Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures.If air 
    conditioner is used outside of the above conditions, certain safety protection features 
    might come into operation and cause the unit  to function abnormally.
2. 

Room relative humidity less than 80%. If the air conditioner operates in excess of this 

    figure, the surface of the air conditioner may attract condensation. Please sets the vertical 
    air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: 

 For the unit adopts an Electric Heater, when the outside ambient  temperature

O

O

 is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to 
guarantee it running smoothly.

NOTE:

Cooling operation

Heating operation

Drying operation

17     62

-15      50      5      122 

  For the models with low 

   temperature cooling system

0      50

32      122

30     86

-15      30

5        86

10     50

0      50

32      122

Summary of Contents for TAS-36EHU

Page 1: ...roblems consult your dealer for help or Turbo Air Conditioning Corp Please keep this manual handy W1 Inverter One One Split Type ROOM AIR CONDITIONER MODEL TAS 36EHU Please read this manual carefully and thoroughly before operating the unit If you still have any difficulties or problems consult your dealer for help or Turbo Air Conditioning Corp Please keep this manual handy W1 Inverter One One Sp...

Page 2: ...uthinstaller for installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play wit...

Page 3: ... free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous subst...

Page 4: ...may cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or firedue to heat generation It may cause electric shock It may cause failure of machine or electric shock It contains contaminants and could make you sick It may cause fire and electric shock It may cause electric shock or fire This could damage your health No installation may cause fire and elect...

Page 5: ...r cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off and disconnect the power contact a qualified service technician It may cause failure of appli...

Page 6: ... 7 Vertical louver on some models 8 Air filter under the panel 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 Connecting cable 15 Connective pipe 16 Stop valve Indoor unit Outdoor unit 6 5 7 8 9 1 2 3 4 13 12 11 Air outlet Air inlet Air inlet rear Air inlet side Air outlet 15 16 14 10 MOD E MOD E FAN SPEE D FAN SPEE D M M AUTO AUTO COOL...

Page 7: ...T indicator For Cooling Heating models only This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation TEMPERATURE indicator CLEAN AIR indication lamp Lights up when CLEAN AIR feature is activated The display panel of the air conditioner you purchased would look like one of the following 1 4 2 3 A Usual...

Page 8: ...fore operating the manual control button If the unit is operational continue pressing the manual control button until the unit is off Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into operation and cause the uni...

Page 9: ...ls the vertical louver can be adjusted by using the remote controller Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode Otherwise condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings Do no...

Page 10: ...t it will switch off This characteristic maintains both enery saving and comfort in night operation DRYING operation The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is O O lower than 10 C 50 F the compressor stops operation and restarts until the room temperature is above O O 12 C 54 F Optimal operation To achieve optimal performa...

Page 11: ...are and maintenance Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops wi...

Page 12: ...xposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution Air freshening filter Air freshening filter 1 2 4 Remove the Air Freshening Filter from its support frame on some models The optional filter include Plasma Dust Collector Silver Ion filter Bio filter Vitamin C filter 3M air ...

Page 13: ... high relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low sque...

Page 14: ...emote controller will stop the unit completely When the power restores or pressing the ON OFF button on the remote controller again the unit restarts automatically with all the previous settings including the open angle of the horizontal louver by the memory function So we strongly suggest that the open angle of the horizontal louver should not be set too small in case the condensed water forms an...

Page 15: ...y first then restart the unit Wait Inappropriate temperature setting Air filter is blocked Doors or Windows are open Air inlet or outlet of indoor or outdoor unit has been blocked Compressor 3 or 4 minutes protection has been activated If the trouble has not been corrected please contact a local dealer or the nearest customer service center Be sure to inform them of the detailed malfunctions and u...

Page 16: ...15 15 ...

Page 17: ...16 16 ...

Page 18: ...17 17 ...

Page 19: ...2020001B4105 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Reviews: