Turbo Air Super Deluxe TSF-23SD Installation And Operation Manual Download Page 6

6

DISPLAY PANEL OF REFRIGERATOR

9

TEMPERATURE

T.C.

8

7

6

5

4

3

2

1

FAN

DOOR

TURBO COOLING

TEMPERATURE

˚F

TEMP. SETTING

TURBO COOLING

FAN RUNNING

DOOR OPENING

TURBO COOLING

BUTTON

TEMP. CONTROL BUTTON

(SEE TO PAGE 7)

INNER TEMP.

(SEE TO PAGE 8)

(SEE TO PAGE 7)

Summary of Contents for Super Deluxe TSF-23SD

Page 1: ...airinc com SOLID DOOR REFRIGERATORS TSR 23SD TSR 35SD TSR 49SD TSR 72SD SOLID DOOR FREEZERS TSF 23SD TSF 35SD TSF 49SD TSF 72SD Super Deluxe Series Refrigerators Freezers Installation and Operation Ma...

Page 2: ...15V 60Hz R 134A 9 0A 357lbs TSR 49SD 1 3 115V 60Hz R 134A 9 2A 427lbs TSR 72SD 1 2 115V 60Hz R 134A 11 3A 602lbs MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TSF 23SD 1 2 115V 60Hz R 404A 7 8A 293lbs T...

Page 3: ...contents 3 DO NOT PLAVE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this u...

Page 4: ...ed 3 CLEAN THE GASKET The door gasket should be cleaned frequently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER C...

Page 5: ...default temprature setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Senser 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set...

Page 6: ...GERATOR 9 TEMPERATURE T C 8 7 6 5 4 3 2 1 FAN DOOR TURBO COOLING TEMPERATURE F TEMP SETTING TURBO COOLING FAN RUNNING DOOR OPENING TURBO COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 7 INNER TEMP SEE...

Page 7: ...de the compressor will return to the normal operation 3 During the Turbo Cooling mode works the temperature Up Down button will not affect the compressor s operation 1 By pushing the up down button yo...

Page 8: ...will be turned on 2 Evaporator fan motor is activated when the door both doors for TSR 49SD all three doors for TSR 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 I...

Page 9: ...ller PCB F Senser 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperature and toward 9 for lower temperatures 6 The interior light is ac...

Page 10: ...ER 9 TEMPERATURE D F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST FAN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 11 INNER TEMP SEE...

Page 11: ...lighted higher level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 times per a day 2 If it is necessary to change the intervals of defros...

Page 12: ...be turned on 2 Evaporator fan motor is activated when the door both doors for TSF 49SD all three doors for TSF 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 In cas...

Page 13: ...he back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open long...

Page 14: ...fter shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or...

Page 15: ...se accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED...

Page 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: