Turbo Air Super Deluxe Series Installation And Operation Manual Download Page 12

13

FOR REFRIGERATORS

BASIC OPERATION

  TSR-23SD-N6
  TSR-35SD-N
  TSR-49SD-N6
  TSR-72SD-N

1. Plug in and turn on the power switch located on the bottom of the top grille right 

 side. The Display panel will be lighted and make a beep sound. The compressor 

  will begin to run.

2. The default temperature setting is No. “5”.

3. The compressor is automatically cycled by the electronic controller

    (PCB, R-Sensor).

4. The Defrost cycle is automatically controlled by the D-sensor, and the PCB.

5. Set level toward “1” for higher temperature and toward “9” for lower

  temperature.

6. The interior light is activated when the door is opened.

7. Evaporator fan motor(s) will run after all doors are completely closed.

REFRIGERATORS

1. CLEANING THE INTERIOR AND EXTERIOR
    - The interior and exterior of the unit can be cleaned using warm water and soap.

    - Do not use an abrasive cleaner because it will scratch the surface. 
2. CLEANING THE CONDENSER COIL
    - To maintain proper refrigeration performance, the Condenser coil must be free of 

      dust, dirt, and grease. This will require periodic cleaning. Condenser coil should 

      be cleaned at least every three months (90days) or as needed. 

    

    - To clean the condenser, unplug the power cord. Condenser can be cleaned with 

      vacuum, brush, or CO2 (high pressure air).

 

  

3. CLEAN THE DRAIN PAN
    - Periodically, empty the drain pan which is located under the unit. 

    - When reinstalling the Drain Pan, make sure the drain hose is placed back into the pan.
4. CHECK AFTER CLEANING
    1) Check the unit again for safety. 

    2) Plug unit back in and turn on power switch. 

    3) Check that the unit is operating properly. 

12

CLEANING

CAUTION

Before cleaning, unplug the unit and disconnect the power. 

Wipe and clean the inside and outside of appliance with a damp cloth.

1. POWER CORD
    - Be sure the power cord is connected to the proper voltage.

    - A protected circuit of the correct voltage and amperage must run for connection of

      the line cord.

    

   - Turn ‘off’ the power switch before disconnected the power cord, whenever 

      performing maintenance functions or cleaning the refrigerated cabinet. 

    

   - Compressor warranties are void if compressor burns out due to low voltage. 
2. RESTARTING
    - If disconnected, wait 5 minutes before restarting. 
3. POSITIONING GOODS
    - Do not obstruct the air inlet which is located at the back inside of the unit.

NOTE: For a self-cleaning condenser equipped model, condenser cleaning is not 

required. However, it is recommended to blow the condenser coil out with Nitrogen 

once or twice a year. Note that the condenser cleaner may not remove grease. 

Summary of Contents for Super Deluxe Series

Page 1: ...TSR 23SD N6 TSR 35SD N TSR 49SD N6 TSR 72SD N SOLID DOOR FREEZERS TSF 23SD N TSF 35SD N TSF 49SD N TSF 72SD N Super Deluxe Series Reach In Refrigerators Freezers Installation and Operation Manual Ple...

Page 2: ...ION SPECIFICATIONS SERIAL NUMBER NOTICE TO CUSTOMER INSTALLATION CLEANING CAUTION BASIC OPERATION FOR REFRIGERATORS FOR FREEZERS TROUBLESHOOTING STAINLESS STEEL EQUIPMENT CARE CLEANING WARRANTY INFORM...

Page 3: ...knowledge are not included in this manual and are not required to be included Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervisio...

Page 4: ...o not puncture refrigerant tubing CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion Fla...

Page 5: ...e The amount of refrigerant in your particular appliance is shown on the label inside the cabinet Never start up an appliance showing any signs of damage When in doubt contact a qualified service prof...

Page 6: ...mmable substances in the refrigerator The storage of benzene thinner alcohol ether LP gas or other explosive substances may cause an explosion Do not store or use gasoline or other flammable vapors an...

Page 7: ...ny containers filled with water on top of the appliance If the water spills onto any electrical parts it may lead to fire or electric shock Do not attempt to repair disassemble or alter the appliance...

Page 8: ...wise there is a risk of fire Do not insert your hand into the bottom area of appliance Any sharp edges may cause personal injury After unplugging the appliance wait at least five minutes before pluggi...

Page 9: ...back of the appliance may not be damaged Information concerning collection schedules or locations can be obtained from the local disposal authorities PROPER DISPOSAL OF OLD APPLIANCE BEFORE YOU CALL F...

Page 10: ...N6 TSR 72SD N 1 8 1 4 1 5 1 2 115V 60Hz 115V 60Hz 115V 60Hz 115V 60Hz R 600a R 290 R 600a R 290 1 5 2 8 2 3 5 7 274 lbs 357 lbs 427 lbs 602 lbs MODEL COMP H P V Hz RERIGERANT AMPS WEIGHT Solid Door F...

Page 11: ...floor on which the unit is to be installed is strong enough to support the total weight of the cabinet and any other contents before starting the installation 4 DO NOT PLACE NEAR HEAT Be sure to avoid...

Page 12: ...in and turn on power switch 3 Check that the unit is operating properly 12 CLEANING CAUTION Before cleaning unplug the unit and disconnect the power Wipe and clean the inside and outside of appliance...

Page 13: ...will begin to run 2 The default temperature setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB R Sensor 4 The Defrost cycle is automatically controlled by the D...

Page 14: ...OF REFRIGERATOR TEMPERATURE 9 8 7 6 5 4 3 2 1 FAN T C DOOR TURBO COOLING TEMPERATURE POWER F TEMP SETTING TURBO COOLING DOOR OPENING TURBO COOLING BUTTON SEE PAGE 15 SEE PAGE 15 SEE PAGE 15 TEMP CONT...

Page 15: ...he Turbo Cooling mode the temperature Up Down button will not affect the compressor s operation UP DOWN BUTTON Temperature control button 1 By pushing the up down button you can set the inside tempera...

Page 16: ...closed DOOR OPENING INDICATOR 1 If any door is opened door opening indicator will be turned on 2 In case any door was opened for around 30 seconds warning beep sound will ring three 3 times 3 In case...

Page 17: ...t cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperatures and toward 9 for lower temperatures 6 The interior light is activated when the door is open...

Page 18: ...EL OF FREEZER TEMPERATURE 9 8 7 6 5 4 3 2 1 FAN T F DOOR TURBO FREEZE TEMPERATURE POWER F TEMP SETTING TURBO FREEZE DOOR OPENING TURBO FREEZE BUTTON SEE PAGE 19 SEE PAGE 19 SEE PAGE 19 TEMP CONTROL BU...

Page 19: ...BUTTON Temperature control button 1 By pushing the up down button you can set the inside temperature level from 1 to 9 2 If you want lower temperatures push the Down button to eight and increase to hi...

Page 20: ...sed DOOR OPENING INDICATOR 1 If any door is opened door opening indicator will be turned on 2 In case any door was opened for around 30 seconds warning beep sound will ring three 3 times 3 In case of...

Page 21: ...n produce dewdrops during rainy seasons The door is opened too frequently or left open too long Damp food is stored The door is bent The unit is not levelde off The door gasket has come off Turn the t...

Page 22: ...dustrial cleaners are the worst type of chlorides to use 8 step that can help prevent rust on stainless steel 1 Using the correct cleaning tools Use non abrasive tools when cleaning your stainless ste...

Page 23: ...immediately It is better to wipe standing cleaning agents and water as soon as possible Allow the stainless steel equipment to air dry Oxygen helps maintain the passivity of the film on stainless stee...

Page 24: ...ea may not be considered as proper installation Additional Two Year Compressor Warranty In addition to the three 3 year warranty stated above Turbo Air warrants its hermetically sealed compressor to b...

Page 25: ...GE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD OR IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM EL...

Page 26: ...26 NOTE...

Page 27: ...www turboairinc com registration within 7 days from the date of purchase Failure to comply may result in your warranty being voided Date of Purchase Name of the Dealer City State Zip Code Turbo Air In...

Page 28: ...www turboairinc com 4184 E Conant St Long Beach CA 90808 Toll Free 1 800 381 7770 Fax 310 900 1033 Email warranty turboairinc com...

Reviews: