background image

CPA6

Installation & User Guide

Compatible Equipment

CPA6 OM - Output Module
9040 - Loudspeaker
DC54/58 - Digital Communicators (Stand Alone Only)

496524 Issue A

1 of 16

CPA6

Summary of Contents for CPA6

Page 1: ...CPA6 Installation User Guide Compatible Equipment CPA6 OM Output Module 9040 Loudspeaker DC54 58 Digital Communicators Stand Alone Only 496524 Issue A 1 of 16 CPA6...

Page 2: ...ection circuits may be connected 10 per zone interfaced via remotely positioned Zone Expansion Module or ZEM ENGLISH TEXT DISPLAY Provides fully detailed information of system status detection circuit...

Page 3: ...en the system is in the test set condition this definition is used TYPE 2 24 hour Circuit This type is selected when continuously monitored detectors are connected typically fire doors tube and wire f...

Page 4: ...nals providing the end of line resistor Detection circuit wiring to Z E M s is via terminals Loop A and Loop B and the E O L resistors must be remote from the Z E M fitted Outputs P A This drives high...

Page 5: ...CLK 0 Loop A Loop B 0 CLK CLK 0 Loop A Loop B 0 CLK 2 off connectors for use as Junction Block for 12V auxiliary supply 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 NOTE Up to Z E M s may be fitted to zone...

Page 6: ...ain Audible L P A Alarm O P Main Audible L TYPE 5 EXIT ENTRY CIRCUIT 24Hr Fault O P Fault Audible NL SHUNTED BY PANEL Main Alarm O P Main Audible L SHUNTED BY PANEL TYPE 6 LAST EXIT SHUNT LOCK CIRCUIT...

Page 7: ...SE 2 Is rated at 1A and is of the Anti Surge type Its function is to protect the supply to the CPA6 circuitry from overloads Failure of FS2 will result in the CPA6 display blanking and the keypad tone...

Page 8: ...of the year Enter the month number of the year via the keypad 01 JANUARY etc As keys are pressed the display will show the month number When this is correct press the YES ENTER key Enters the display...

Page 9: ...number of detection circuits that the panel identifies on Zone 2 REPEAT STEP 21 FOR ZONES 2 TO 6 The display shows the number of detection circuits that the panel identifies on the last Zone Zone 6 Co...

Page 10: ...t by subscriber or by Engineer into memory and initiates the next step of commissioning The routine first assumes that P A alarms operate the main alarm audibles following a preset delay during the sy...

Page 11: ...ER key operated If entry to the premises is to be timed then enter the required entry time in seconds via the keypad Registers that the alarm system has infinite entry time As keys are pressed the dis...

Page 12: ...r information from the keypad The P A Code is a 4 digit keypad code which whenever operated activates the panels P A output The Code is particularly useful to a subscriber OPENING the alarm system und...

Page 13: ...ers User code x in the panel s memory Selecting this User routine will enable the alarm system to be fully tested and set opened by the Engineer without knowledge of any user Code The commissioning ro...

Page 14: ...nly if this facility has been programmed 1 Ensure that all monitored areas except those to be shunted excluded are secured 2 The panel display should show the date and time and System Open 3 Enter you...

Page 15: ...panel display will show Do you want to set the system 4 Press NO The display will show Do you want Tests Press YES ENTER 5 The display will show Do you want Bell Test 6 Press YES ENTER The display wil...

Page 16: ...CPA6 CPA6 16 of 16 496524 Issue A This page intentionally left blank...