background image

Installation and User Manual

D9007050A

User Alert Pager System

Installation

The pager transmitter is driven by the data output from the ‘Printer Port’ of the Control
Card of any type of Haven, Communicall, or Vision system. It is powered from the fused
battery-backed 14V supply provided on the ‘Pager Port’.

The Pager Transmitter should be sited indoors, at roof level, at least 2m away from other
equipment. The following diagram illustrates the wiring interconnections between the
Haven or Communicall Control Card and the Pager Transmitter.

IMPORTANT – if a system printer is also fitted then the printer RTS signal (normally
connected to PBY) MUST be disconnected.

Configuration

No configuration of the Pager Transmitter is required.

If paging on an external fire panel activation is required then this should be implemented
either via a speech module (must be coded to 999), with the fire panel input connected to
the smoke input, or via the fire panel input on the control card. In the latter case, the
system must be configured to generate a 795 call.

Ensure the Scheme Manager and Control Centre Manager are aware of speech module
i.d. changes.

Pager Transmitter

ON

TX

RTS

RXD

Control Card

14V

PDA

PBY

Pager Port

Printer Port

Red

Black

White

Blue

10 core cable
GS013

Printer

Data

RTS

No Connect

F2A

0V

Installation and User Manual

D9007050A

User Alert Pager System

Parameter

Value

Notes

Page 0 - 12

1

Enable printer

Page 0 – 25

32

Page 0 – 26

32

Ensure termination characters set correctly

Page 0 – 36

243

Page 0 – 37

128

Ensure printer baud rate set to 2400

Page 0 – 40

255

Printer busy line set to 0 = busy

Page 0 – 87

255

Ensure DES activity printed (if applicable)

Page 1 -  259 (Communicall only)

7

Page 1 -  259 (Communicall only)

9

Page 1 -  259 (Communicall only)

5

Ensure fire panel input coded to 795

Each Pager Receiver used on the system MUST be coded to the speech module i.d.
number of the resident concerned. This procedure is carried out using a programming kit
(Tunstall part number 9000/70A) and is detailed in Technical Bulletin TB297.

Licensing of Equipment

A licence must be obtained for the pager system from OFCOM – Details can be obtained
from http://www.ofcom.org.uk/

Testing

On application of power, the red LED on the Pager Transmitter will illuminate. The green
LED will illuminate for approximately 2s whilst the Pager Transmitter is transmitting.

In order to test the system, generate all events of interest on the Haven or Communicall
system and check that all the pagers assigned to the system respond appropriately.

User Instructions

Each Pager Receiver is supplied with a comprehensive instruction booklet. Basic user
instructions are provided here, to be carried out with reference to the diagram below.

Selection
Button

Left
Button

Right
Button

Reading
Button