Tünkers 8-Channel Motor Terminal
for controlling maximum 8 electronic clamping devices
TMI8 V2.1
Subject to technical alterations
Page -6-
06/03/2018
TÜNKERS
®
Maschinenbau GmbH Am Rosenkothen 8 • D-40880 Ratingen Tel. 02102 4517-0 • Fax 02102 445808 Internet www.tuenkers.de
XE1 - XE8:
M12 connector for the end position sensor clamp (Close) /
releasing (Open)
XE9:
M12 connector for general binary inputs BE1 and BE2
XE10:
M12 connector for general binary inputs BE3 and BE4
XE11:
M12 connector for general binary inputs BE5 and BE5
XE12:
M12 connector for general binary inputs BE7 and BE8
The device TMI-8-PN or EIP is equipped with an Ethernet inter-
face:
XBA:
Output ProfiNet IO interface or
Ethernet-IP M12 socket for Industrial Ethernet 4-
pin coding D
– Data
XBE:
Input ProfiNet IO interface or Ethernet-IP M12 socket for Indus-
trial Ethernet 4-pin coding D
– Data
A bus structure can be established by both connectors.
The device TMI-8-PB is equipped with a Profibus interface:
XBA:
Output Profibus interface M12 socket 5-pin B-
coding
XBE:
Input Profibus interface M12 connector 5-pin B-
coding
A bus structure can be established by both connectors.
The device TMI-8-DN is equipped with a DeviceNet interface:
XBA:
DeviceNet interface M12 5-pin socket
–
coding A standard
XBE:
DeviceNet interface M12 5-pin connector
–
coding A standard
Pin no.
Designation
1
+24V
2
Feedback Open
3
0V
4
Feedback Close
Pin no.
Designation
1
+24V
2
BE1
3
0V
4
BE2
Pin no.
Designation
1
+24V
2
BE3
3
0V
4
BE4
Pin no.
Designation
1
+24V
2
BE5
3
0V
4
BE6
Pin no.
Designation
1
+24V
2
BE7
3
0V
4
BE8
Pin no.
Designation
1
TD+
2
TD-
3
RD+
4
RD-
Pin no.
Signal
Designation
1
VP
+5V supply for
bus termination
2
RxD/TxD-N
Data conductor Minus
( A
– conductor)
3
DGND
Data ground
4
RxD/TxD-P
Data conductor Plus
( B
– conductor)
5
nc
Not assigned
Thread
Screen
Ground / mass connection
recommended
Pin no.
Designation
1
Screen
2
U+
3
U-
4
CAN-H
5
CAN-L
Pin no.
Designation
1
Screen
2
U+
3
U-
4
CAN-H
5
CAN-L