Installation to Wall
When fixing the heater to a wall, ensure hinges are in the
underside so that the lid hands down in the open position.
Minimum required distances:
a) 500mm from the side wall
b) 500 mm from the ceiling
c) Installation height above 1.8M
Installation to Ceiling
Minimum required distances:
d) 250mm from the side wall
e) Minimum 500mm from the ceiling(range:500mm-750mm)
f)
Installation height above 1.8M
The heater must be fixed to a wall with the bracket supplied to
allow adequate ventilation.
Never fix or place heater near flammable or combustible materials.
Generally heaters must be placed at a safe distance (clear space)
of at least 2.0m from combustible materials and glass walls. If
installed in workshops or garages where inflammable or
combustible paints are used, the heaters must be installed at a
distance of at least 4.0m from the source of danger.
If the heaters are placed in areas where spray painting of any
description is taking place, they should not be used during the
painting operations.