Tufner T918M User Manual Download Page 1

T918M User Manual

 

motorized pallet jack scale

www.tufner.com

Summary of Contents for T918M

Page 1: ...T918M User Manual motorized pallet jack scale www tufner com...

Page 2: ...p 1 Features 2 Specifications 3 Part Descriptions 4 Instructions 5 Power Supply 6 Features 4 Display and Key Descriptions 7 Operating Instructions 8 10 Calibration 11 12 Indicator Parameter Settings 1...

Page 3: ...sure the weight is not over the max capacity as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the sa...

Page 4: ...e Accumulation weighing Printer optional Splash proof keyboard and display Power saving mode NTEP approved for 3 000 divisions Rechargeable battery Technical Parameters Stimulating voltage 3 3VDC A D...

Page 5: ...3 SPECIFICATIONS...

Page 6: ...4 forward raise lower forks raise lower forks alarm forward or backward forward or backward BATTERY 0 1 STOP charging cord battery indicator power switch emergency off switch PART DESCRIPTIONS...

Page 7: ...on motorized pallet jacks you don t have to manually pump motorized ones Press the forward buttons and use the handle to steer Direct the elec tric pallet jack to the location where you want to unload...

Page 8: ...ry weight 100lb Battery Rated Capacity 75Ah Indicator Battery The indicator is charged through the pallet jack adapter To keep the battery in best condition fully discharge the battery every month by...

Page 9: ...OFF to enter into calibration 3 Combined with the TOTAL key to check the Accumulative sum lb The weight is shown in pounds kg The weight is shown in kilograms Hold Shows you are in Hold mode Gross Sh...

Page 10: ...r that you will receive an error and will need to tare out the weight Tare Function The Tare function is used when you only wish to see the cur rent change in weight not the entire amount of weight th...

Page 11: ...number n the number of weights you are adding together will flash on the display followed by the total The total will display by flashing between 2 sets of numbers There are 8 digits in total the dis...

Page 12: ...to Hold If the weight on the scale is above 20d 20 x division and is stable the indicator will hold that weight on the screen for 3 seconds then go back to general weighing Pressing the hold key is un...

Page 13: ...aximum capacity you want to use for this scale by using TOTAL to move the cursor to the right and UNIT and ZERO to move the val ues down and up The C4 channel is used to enter in the max capacity of t...

Page 14: ...ation weight on the scale 4 If the scale does not show the value of the calibration weight check that the pallet jack is level on the ground and on a flat surface and recalibrate 5 Unload the scale th...

Page 15: ...r Settings Options Weighing Unit C01 1 kg 2 lb 3 gram 4 oz Note for calibration only kg or lb are allowed Decimal Setting C02 0 no decimal 1 0 0 2 0 00 3 0 000 4 0 0000 Division Graduation Setting Rea...

Page 16: ...seconds Inner Code Display C15 check the inner code raw data Set Date C16 Set date from left to right year month day Set Time C17 Set the time from left to right hour minute second Manual Zero Range...

Page 17: ...5 5 digital filter strength 6 6 digital filter strength Note The higher the number the higher the filter strength Noise Filter C29 0 turn off noise filter 1 1 digital filter strength 2 2 digital filte...

Page 18: ...Alarm C14 000000 Inner Code Display C15 Set Date C16 Set Time C17 Communication Setting C18 0 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracking C22 0 5 Zero Trackin...

Page 19: ...the time allowed for the scale to fall within the zero tracking range tolerance and still qualify to be zero d Overload Range Weight allowance that is out of the set calibrat ed range Adds a tolerance...

Page 20: ...nnect with 4 load cells of 350 at most 4 wire or 6 wire load cell connections are both okay Please contact us directly if you have other special needs for your application There are two connection met...

Page 21: ...See Q A section ERR1 During calibration weight is not used or the weight is above the max capacity Use correct weight within the defined range ERR2 During calibration the weight is below the minimum...

Reviews: