Tuffcare T8036 Operation Manual Download Page 10

LIMITED WARRANTY

LIMITED WARRANTY

The warranty below has been drafted to comply with Federal Law applicable
to products manufactured after July 4, 1975.  This warranty is extended only
to the original purchaser/consumer (or dealer non-consumer who does not
buy for resale).

Tuffcare

®

warrants that it’s proprietary Institutional Beds will be free from

defective workmanship and materials for a period of three (3) years following
the date of original manufacture with the following exceptions: All welds are
warranted for the life of the bed.  Electronics on the beds are warranted for
one (1) year.  The warranty period commences on the original manufacture
date.  If within such warranty period any such product proven to Tuffcare

®

satisfaction to be defective, such product will be repaired or replaced at
Tuffcare

®

option.

Tuffcare

®

sole obligation and your exclusive remedy under this warranty

shall be limited to such repair and/or replacement. This warranty does not
include any labor charges incurred in replacement parts installation. Freight
charges to the factory are at the expense of the consumer or seller. Return
freight charges will be prepaid by Tuffcare

®

. For warranty service, please

contact the authorized dealer from whom you purchased your Tuffcare

®

products. In the event that you do not receive satisfactory warranty service,
please write directly to Tuffcare

®

: 4977 La Palma Ave, Anaheim, California,

92807. DO NOT RETURN PRODUCTS WITHOUT PRIOR AUTHORIZATION.

LIMITATIONS AND EXCLUSIONS: The foregoing warranty shall not apply
to products subjected to negligence, abuse, misuse, improper operation,
improper maintenance, improper storage or damages beyond Tuffcare

®

control. The evaluation will be solely determined by Tuffcare

®

. The warranty

shall not apply to problems arising from normal wear, or failure to follow
instructions, or if parts are not manufactured by Tuffcare

®

, or do not comply

with original equipment specifications that are added to Tuffcare

®

product.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE AND SHALL NOT EXTEND BEYOND THE DURATION OF THE
EXPRESS WARRANTY PROVIDED HEREIN. TUFFCARE

®

SHALL NOT

BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES WHATSOEVER.

This warranty gives you specific rights and you may also have other legal
rights which vary from state to state. Some states do not allow the exclusion
or limitations of incidental or consequential damage, or limitation on how
long an implied warranty

18

17

MAINTENANCE

MAINTENANCE

CLEANING THE BED

•  The Bed can be cleaned with non-abrasive cleaners.

Make sure that the wheels are free of hair, lint and
other debris.

DETECTING WEAR AND DAMAGE

• Check monthly that all screws are tight and have not 

loosened.

• Check monthly for damaged or exposed wires on the

electrical components.

• Inspect monthly for signs of cracking, fraying or any

deterioration.

• Contact your equipment provider for replace of any 

defective parts immediately and ensure that the bed
is not used until repair job is completed.

LUBRICATING THE BED

•  A light grease lubricant may be applied to the ball

bearing and swivel of the casters every three months.

PERFORMING REGULAR MAINTENANCE

•  Regular maintenance of the bed and accessories is

required to ensure proper operation.  The casters and 

axle bolts are also required to be checked for proper

tightness.

Summary of Contents for T8036

Page 1: ...Century T8036 T8042 Long Term Care Bed Operation Manual CENTURY_T8000_V1 0 ...

Page 2: ... of a TUFFCARE Century TM bed Our deluxe long term care bed is specially engineered and designed for Alzheimer residents or others with chronic impairments which will reduce their degree of independence in activities of daily living The T8000 is a fully electric adjustable bed The bed height head and foot angles functions are standard along with trendelenburg and reverse trendelenburg functions th...

Page 3: ...at any moment ASSEMBLING PRECAUTIONS ASSEMBLING PRECAUTIONS L Pre assembled one piece grid design frame with fully loaded electronics system requires minimum set up L Do not over tighten mounting hardware It will cause damage to mounting brackets L Be sure that bed side rails are properly attached on main frame before the patient is moved into the bed L Secure the caster locks in place to prevent ...

Page 4: ...0 inches Board Height from Fabric 15 inches Weight Capacity 600 lbs Weight T8036 205 lbs T8042 232 lbs Emergency Backup Battery Yes Limited Warranty Bed Electronics 3 Years 1 Year 6 Hardware Pack A 8 pcs of Phillips Pan Head Screws with Caps B 4 pcs of Pin Locks C 2 set of Supporting Bars D 4 set of Hex Drive Pan Head Screws with Nut E 2 set of supporting brackets ASSEMBLY ASSEMBLY ASSEMBLING THE ...

Page 5: ...ll headboard and fooboard using 2 pcs of phillips pan head screws to secure the headboard or footboard on supporting bar and use hole plug to cover the screw Repeat the process for the other side 2 Using two set of hex drive pan head screw with nuts to secure supporting bracket on the side of the end of head and foot Section of main frame then repeat the other side 3 Use both hands to position the...

Page 6: ...tress in the middle to hold it in place Mattress Stop 9 4 Install bolt and tighten into the holes while holding the nut with your other hand 5 Use 7 8 wrench bolt wrench Nut to secure the swing bars on top head section frame 6 Connect the 4 pin round plug into the junction box for optional bed side rail with Hi low control panel ...

Page 7: ...ugged into a grounded 110 Volt outlet Before operating make sure casters are in their proper operating position Hand Controller Functions press button indicated to move bed RAISING LOWERING THE BED 11 PREPARING THE BED FOR USE 1 Make sure all of electronic components are well connected and all of wires are clear from moving parts 2 Check and tighten all hardware BEFORE use L WARNING The user must ...

Page 8: ...urg Reverse Trendelenburg Patient attend control panel A B C D E Caregiver control panel 13 PENDANT FUNCTIONS Press indicated buttons to move the bed up and or down A Head Section B Foot Section C Head Foot Section D Hi Low E Trendelenburg Reverse Trendelenburg To achieve the lounge chair position for reading or eating press the trendelenbrg buttom to reach its fullest tilt At the same time rise t...

Page 9: ...ILS 15 JUNCTION BOX FUNCTIONS Control of all of electronic components A Hand Pendant Control Panel B Head Motor C Foot Motor D Hi Low Motor installed on Foot Main Frame E Hi Low Motor installed on Head Main Frame F Battery Indicator Light green when charged G Fuse Box H Power Cord with I Ground connection J Built in Backup Re chargeable Battery Use built in rechargeable battery backup power for em...

Page 10: ...nance improper storage or damages beyond Tuffcare control The evaluation will be solely determined by Tuffcare The warranty shall not apply to problems arising from normal wear or failure to follow instructions or if parts are not manufactured by Tuffcare or do not comply with original equipment specifications that are added to Tuffcare product THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...