Filling Your Spa
Confirm that the drain valve is closed. Unthread and remove the filter. Place garden hose in the
void where the filter was, this will help to eliminate air locks. With the electrical breaker in the
OFF position and/or the power cord un-plugged, fill to an approximate water level that will not
allow water to over flow the spa when bathers are in the hot tub. Every bather’s density is different
and therefore water level may vary (remember to make sure that the filter is covered). Once the spa
is filled, power can then be supplied to your spa.
NOTE: Please ensure that the water level does not cover or submerge any equipment for an
extended period of time when people enter the spa due to water displacement. If this happens,
please lower the water level to prevent this as it could cause damage to the spa components that
would not be covered under warranty.
Relieving Air Locks
Occasionally, on a fresh fill or refill, an air lock may occur. This is caused by the build up of air in
the plumbing lines which will not allow water or air to flow through the jets. If left un-attended, the
pump can overheat from lack of water flow. This type of damage is not covered under the
warranty. The easiest way to remedy this situation is to repeatedly cycle between low- and high-
speed on the topside controls. If this does not fix the issue you will have to open the access panel
that houses the pump. Once the panel is removed, locate the pump and you will see two large,
white nuts attached to the pump. One is horizontal to the pump and the other is vertical. Take a
large pair of channel locks and loosen the horizontal nut with the pump in high-speed. Continue to
loosen the nut until the jets begin to work. Doing this will cause water to come out the nut you are
loosening which is normal. Once the jets are functioning properly, tighten the nut back up and put
the panel back on.
Adjusting Massage Jets
To adjust for direction, rotate the "eyeball" of the jet in the desired direction. To adjust for flow,
turn the outer jet face counter clockwise to increase flow and clockwise to decrease flow. At no
time fully decrease flow to all of the jets. This may cause your pump to malfunction and suffer
catastrophic failure which will not be covered under the warranty.
Air Adjustment
To introduce air into the jets, turn the air controls (located on the spa's top edge) counter
clockwise. To decrease air flow, turn the air controls clockwise.
Suction Fitting
Keep the suction fitting (located in the foot well area) of the spa unobstructed and free from debris
at all times. Only remove the suction-fitting screen for cleaning. Never remove it while the spa is
connected to electrical power.