background image

Universal Key-Pad 

TAP  

F.  Test Program 

I.  Off:  Test function inactive. 

II. 

On:  Test function active.  Control will repeatedly and automatically command an opening.  If any faults are found, 
they will show on the display.

 

NOTE: If no faults are found, the door will repeatedly cycle open/close until the function is switched off again. 

G.  Exit 

6.  CLOCK 

A.  Sets the current day, time and date 

7.  TIMER 

A.  Off:  Timer not activated 

B.  On:  Timer is activated and functions according to the time bands set in the TIMER PROGRAMMING function. 

NOTE: When the Timer is activated, a “T” appears at the side of the time showing in the display and the TAP will not 
allow any operational selection.  If power is lost and the battery is discharged, a flashing asterisk (*) appears in place 
of the “T”, and the system automatically reverts to Off.

 

8.  TIMER PROGRAMMING 

A.  Operation:  Up to 5 different time bands can be created for each day of the week by setting a start time and a func-

tion for each band.  When the TAP’s internal clock reaches the preset start time for a respective band, the associated 
function starts and runs until the next band takes over.  The TAP must remain connected at all times for this function 
to work. 

B.  Select the day:  Select the day(s) of the week to create the time band.  If “all days” is selected, time band defined will 

be applied to all days of the week. 

8.  Number value appears in display. 

9.  Press Up or Down arrows until the value 5 appears. 

10.Press OK. 

11.  Press Down arrow until KEEP SETTINGS displays. 

12.  Press OK. 

13.  Select ON. 

14.  Press OK. 

15.  Press Down until EXIT displays. 

16.  Press OK. 

PROGRAMMING EXAMPLE 

Set OPENING SPEED to a value of 5 and choose to KEEP SETTINGS: 

1.  Press the down arrow until ADVANCED MENU appears in the 

display. 

2.  Press OK 5 times to scroll past setting the PASSCODE (default is 

000). 

3.  OPERATION appears in the display. 

4.  Press OK. 

5.  CLOSING SPEED displays. 

6.  Press Down arrow until OPENING SPEED displays. 

7.  Press OK. 

E.  Change password 

I.  Password-Password-Password-Password 

C.  Select the function:  Set the function to be associated with time band.  Refer to the table on the next page for availa-

ble selections: 

RUN 

DESCRIPTION 

No Function 

Automatic Bi-Directional Full Opening 

Automatic 1-Way Full Opening 

Automatic Bi-Directional Partial Opening 

Automatic 1-Way Partial 

Door Held Fully Open 

Door Held Partially Open 

Manual (Off) 

Night Function 

7.  Once you are at the desired sub-sub-main menu item, press OK. 

8.  Once all settings within a main menu category are complete, press the Up or Down arrows to the EXIT option and then 
press OK. 

 

NOTE:  Not all menu items have an EXIT option.  In this case, simply press the Up or Down arrows to advance through 
the remaining menu items. 

PROGRAMMING 

To begin programming, perform the following steps: 

 

1.  Press the Up or Down arrows to scroll to the desired main 

menu item. 

2.  Once you are at the desired main menu item, press OK. 

3.  The sub-menu will appear. 

4.  Press  the Up or Down arrows to arrive at the desired sub-

menu item. 

5.  Once you are at the desired sub-main menu item, press OK. 

6.  If there is a sub-sub-menu item available, again press the Up 

or Down arrows to scroll to the desired sub-sub-menu item. 

 

UP-DOWN-OK  

BUTTONS 

Summary of Contents for TAP

Page 1: ...all dress plate E into the programmer module D Upon powering on the display on the TAP control will show a date time and the red LED s will illuminate to indicate current function positions The function of the door can be altered by pressing the desired button Pressing a button more than once toggles between functions for that button i e button number 4 can be used to command a door opening for te...

Page 2: ...3 LOCK A Kit Lock I On Lock installed A Night The door is locked when On Off switch is OFF B One Way Night The door is locked when the On Off switch is in the Night or One Way position C Always Door is locked whenever it is closed II Off No lock installed 4 DIAGNOSTICS A Version III 2 Leaves Pairs A Off No controls linked to each other B On 2 controls are tied together Terminals 26 to 26 and 28 to...

Page 3: ...ress OK 13 Select ON 14 Press OK 15 Press Down until EXIT displays 16 Press OK PROGRAMMING EXAMPLE Set OPENING SPEED to a value of 5 and choose to KEEP SETTINGS 1 Press the down arrow until ADVANCED MENU appears in the display 2 Press OK 5 times to scroll past setting the PASSCODE default is 000 3 OPERATION appears in the display 4 Press OK 5 CLOSING SPEED displays 6 Press Down arrow until OPENING...

Page 4: ...iation of Automatic Door manufacturers AAADM This inspection must be performed by a certified AAADM trained inspector Tucker recommends this documented inspection be performed upon completion of the installation as well as following the completion of every service call thereafter If service is not performed within one year of the previous service action a routine AAADM inspection should be perform...

Reviews: