Air curtain systems AVANTGARDE/TWISTO/ORA/SAMUM/VIRADO
22
5.3.2
&RQQHFWLRQWRPDLQVHOHFWULFLW\VXSSO\
&RQQHFWLRQ RI WKH DLU FXUWDLQ V\VWHPV
AVANTGARDE, TWISTO, ORA, SAMUM and
VIRADO
WRVLQJOHSKDVHDOWHUQDWLQJFXUUHQWSHUIRUPDQFHFODVV/16+(
Alternative current connection of air curtain systems AVANTGARDE/TWISTO/ORA/SAMUM and VIRADO
LOOXVWUDWLRQH[HPSODU\W\SH25$UHVS9,5$'2
With all connecting modalities:
• Lead the power cables through one of the rubberised ducts, at the types TWISTO resp.
VIRADO -standing variabilities- through the stand base or the base plate or the brackets.
• Remove the insulation of the cable ends.
• Stick the earth, neutral and positive cables into the correspondingly marked free connec-
tion points.
•
&KHFNWKDWDOOFRQQHFWLRQVDUHFRUUHFWO\LQSODFH
•
1RZ VHW XS WKH SRZHU VXSSO\7KH SLORW ODPS /(' RQWKH FLUFXLW ERDUG PXVW QRZ EH
blinking
. If the status is
permanent illumination
or OFF, there is a problem with the bus
FRPPXQLFDWLRQ3URFHHGDVSHUSRLQWLQWKHWDEOHRQIDXOWDQDO\VLVVHFWLRQS
LED
LED on main board
LOOXVWUDWLRQH[HPSODU\W\SH25$UHVS9,5$'2
• Switch off the power again and then close the cover plate and air intake grate.