TCB-
66
0 Circuit Description Page 1
4
T
TI
200
7
-
02
-2
3
5.
Test Equipment Setup and Alignment Instructions
5-1 General Section
5-1-1 Test Equipment Required
•
DC power supply(13.8V/3A)
•
DC Voltmeter or Oscilloscope
•
RF attenuator (30dB)
5-1-2 Alignment Procedure
Step Setting
Connection
Adjuster
Adjust
for
1
RX VCO voltage Adj.
Channel & Frequency :
1CH, 26.956 MHz
Mic : Receive
Volume : Optional
Squelch : Optional
RF Gain : Optional
Mic Gain : Optional
DC voltmeter to VCO
Test point (Figure 1)
L301
1.5~2.0 V DC
2
TX VCO voltage Adj.
Channel & Frequency :
1CH, 26.956 MHz
Mic : Transmit(No Mod)
Volume : Optional
Squelch : Optional
RF Gain : Optional
Mic Gain : Optional
DC voltmeter to VCO
Test point (Figure 1)
L301
1.5~2.0 V DC
Figure 1