background image

400A AC/DC CLAMP METER

AUTO RANGING

PART NO:  

TTICM600V  

(..151478)

OPERATING

INSTRUCTIONS

Summary of Contents for PROFESSIONALS TTICM600V

Page 1: ...400A AC DC CLAMP METER AUTO RANGING PART NO TTICM600V 151478 OPERATING INSTRUCTIONS...

Page 2: ...asurement 10 Continuity Test Resistance Diode Capacitance Measurement 11 Non Contact NCV AC Electric Field Sensing 12 Other Functions 13 TECHNICAL INDEX 14 Accuracy Specifications 14 DC Current Measur...

Page 3: ...s all warnings and notes INTENDED USE The clamp meter is to be used only for electrical inspection within the specifications the machine is rated for Failure to use the machine within the specificatio...

Page 4: ...ment before and after using it to ensure that it is in good working condition This product has been tested to the requirements of IEC 61010 CAT II Applicable to test and measuring circuits connected d...

Page 5: ...ter in an explosive or flammable environment high temperature high humidity or strong electromagnetic field Comply with local and national safety regulations and requirements Use personal protective e...

Page 6: ...Power supply 2 x AAA 1 5V batteries Dimension 215mm x 63mm x3mm EXTERNAL OVERVIEW 1 2 4 6 3 7 10 9 5 8 1 NCV sensor 2 Clamp jaws 3 Hand guard 4 LED indicator 5 Jaw opening trigger 6 Function selector...

Page 7: ...C voltage measurement V AC voltage measurement A AC current measurement A DC current measurement NCV Non contact voltage measurement Hz Frequency duty radio measurement Diode measurement Continuity me...

Page 8: ...mposite scale press this button to switch between the corresponding functions or ranges REL ZERO Press this button to store the current reading as a reference for future readings When the LCD display...

Page 9: ...REL button to return to zero before the DC current measurement and meanwhile the centre hole of the jaw should be perpendicular to the current direction to ensure accuracy The open circuit zeroing re...

Page 10: ...ve 600V to prevent electric shock or damage The input impedance of each range scale is 10M this load effect in high resistance measurement may cause error If the input impedance is lower the than 10k...

Page 11: ...y Before measuring resistance disconnect all power and fully discharge all capacitors to avoid injury or device damage If the resistance is over 0 5 when the test leads are short circuited check the t...

Page 12: ...ith beeps and a red LED flashing 3 As the intensity of the measured electric field increases more segments display the buzzer beeps quicker and LED flashes faster 4 If the electric field is around 110...

Page 13: ...he meter again to disable the auto power off function Restart the meter after shutting it down to resume the function Low battery detection The battery voltage will be automatically detected as long a...

Page 14: ...ional temperature coefficient error is 0 1 x specified accuracy C DC CURRENT MEASUREMENT RANGE RESOLUTION ACCURACY 40A 0 01 A 2 5 400A 0 1A AC CURRENT MEASUREMENT RANGE RESOLUTION ACCURACY 40A 0 01 A...

Page 15: ...sinusoidal wave can reach 3 0 at 4000 counts while it can only reach 1 8 at 6000 counts The additional error should be added for the corresponding crest factor as follows a Add 3 when the peak factor...

Page 16: ...0uF 0 1 F 4mF 0 001mF 10 40mF 0 01mF CAUTION Measured value displayed value open circuit value of the test leads For capacitance 100nF REL mode is recommended open circuit has residual reading The gua...

Page 17: ...c field sensing sensitivity is divided into two levels EFHI EFLo The meter defaults to EFHI 1 AC Voltage above 24V 6V can be sensed EFLo mode is recommended when the power frequency voltage is 110V 2...

Page 18: ...ester or test leads if they appear to have any abnormality The maintenance and service must be implemented by qualified professionals or designated service departments BATTERY REPLACEMENT When the sym...

Page 19: ...19 OPERATING MANUAL...

Page 20: ...be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also ent...

Reviews: