![TTI EX752M Service Manual Download Page 2](http://html.mh-extra.com/html/tti/ex752m/ex752m_service-manual_1178788002.webp)
Table of Contents
Specification
OUTPUTS
Voltage Range:
0V to 75V minimum, Modes A and B.
0V to 150V minimum, Mode C.
Current Range:
0A to 2A minimum, Modes A and C.
0A to 4A minimum, Mode B.
Output Voltage Setting:
By coarse and fine controls.
Output Current Setting:
By single logarithmic control.
Operating Mode:
Constant voltage or constant current with automatic cross-over.
Output Switch:
Electronic. Preset voltage and current displayed when off.
Output Terminals:
4mm safety terminals on 19mm (0.75”) pitch.
Output Impedance:
Typically <5m
Ω
in constant voltage mode.
Typically >50k
Ω
in constant current mode (voltage limit at max).
Output Protection:
Output will withstand forward voltage of up to 85V (Modes A and B) or
170V (Mode C).
Reverse protection by diode clamp for reverse currents up to 3A.
Load & Line Regulation:
<0.01% of maximum output for a 90% load change or 10% line change;
<0.1% load regulation for Mode C (150V/2A).
Ripple & Noise
(20MHz bandwidth):
Typically <2mVrms, <15mV pk-pk, constant voltage mode.
Transient Response:
<200µs to within 50mV of set level for 90% load change.
Temperature Coefficient:
Typically <100ppm/°C
Status Indication:
Output on lamp. Constant current mode lamp.
1
Summary of Contents for EX752M
Page 1: ...EX752M 75V 150V Multimode Power Supply Service Manual Manual Part Number 48511 0470 Issue 1 ...
Page 20: ...Component Layouts Main Board 19 ...
Page 21: ...Control Board 20 ...
Page 22: ...Circuit Diagrams 21 ...
Page 23: ......
Page 24: ......
Page 25: ......