background image

 

21 

 

 

Setting of measuring range 

 

  Setting of resistance measuring range 

 

Changeover the display to Rr or RV with the   

 

 VEW 

 key. 

 

Select the resistance measuring range with the 

 

 RANGE 

  key.    The lamp of the selected range 

 

is lit up. 

 

Note

:  In case that the resistance measuring   

 

range and the comparator range are 

 

different, the comparator range is 

 

displayed in blinking. 

 

 

AUTO

 lamp is lit up on 

AUTO

 range. 

 

  Setting of voltage measuring range 

 

Select the Vv display with the 

 VEW 

 key. 

 

Select the measuring range with the   

 RANGE 

 

key.    The selected range is indicated on the main 

 display 

section. 

 

(

AUTO

 range can not be set.) 

 

Setting of comparator 

 

Press the 

 SEL 

  key, and the highest digit of the 

HI 

SET

 blinks to make the comparator setting. 

(Refer to the article 3.13.3) 
 

Finish 

 

Press sequentially the 

 SHIFT 

  key and the (

SET

)

 

key, 

then the memory setting finishes and the meter 
returned to the measurement under memory mode. 
 

 

Ω

OHM

Ω

AUTO

No.

M AN' L

±Δ%

RA NGE


30Ω
300Ω
3kΩ

FL

300mΩ

30mΩ

HI

0 .AD J

S HIF T

LOC K

HI SET

LO SET

REF

RATI O

ONLINE

VE W

 

OHM

Ω

AUTO

No.

M AN' L

±Δ%

RA NGE


30Ω
300Ω
3kΩ

FL

300mΩ

30mΩ

HI

0 .AD J

S HIF T

LOC K

HI SET

LO SET

REF

RATI O

ONLINE

VE W

 

Summary of Contents for 3566

Page 1: ...I 01529 TSURUGA ELECTRIC CORPORATION MODEL 3566 Digital AC mΩ Meter Instruction Manual ...

Page 2: ...ng method 15 3 14 Buzzer 18 3 14 1 Setting method 18 3 15 Manual mode 19 3 16 Memory mode 19 3 16 1 Selection of memory 19 3 17 Setting of memory 20 3 18 Detection of disconnection and self check 22 3 18 1 Operation 22 4 Remote control 23 4 1 Remote connector 23 4 1 1 Pin operation 23 4 1 2 Remote operation of memory mode 24 4 1 3 Timing chart of remote control 25 4 2 Remote control input and outp...

Page 3: ...e meter with the power source voltage within 90 250VAC and the frequency 50 60Hz When connecting the power supply cable confirm that the power supply switch is turned OFF 1 2 2 Power supply cable The plug of power supply cable connected to the meter is for 100VAC use When the meter is used with 200VAC replace the plug with appropriate one for 200VAC use Please connect the power supply cable to the...

Page 4: ... GP IB RS 485 and RS 232C SHIFT key Blue key becomes effective while the SHIFT lamp is lit up LOCK While the SHIFT lamp is lit up it can be turned off by pressing this key The key prohibits the key operation on the front panel The pressing of the key for 3 seconds or more allows prohibition or cancellation During the prohibition the LOCK lamp is lit up VEW key Key to select the display mode RANGE ...

Page 5: ...age V Range lamp In resistance display mode The measuring range is lit up The comparator range is lit up in blinking In voltage display mode Turned off In resistance voltage display mode The resistance measuring range is lit up AUTO lamp Lit up in AUTO range measurement Main display section The measured values and various characters are displayed In Rr mode The measured resistance value is display...

Page 6: ...ower source switch ON OFF switch of the power supply REMOTE connector Connector for the remote control Input and output Terminals for input of hold and reset and for output of resistance terminal blocks comparator Analog output Terminals to output the DC voltage proportional to the measured value terminals ZERO ZERO volume of the analog output MAX MAX volume of the analog output Inlet for interfac...

Page 7: ...k status 4 Buzzer status 3 Zero adjust condition 3 2 Connection of measuring terminals Make a connection to the measuring terminals on the front panel or rear panel as the Fig 3 2 1 shows Fig 3 2 1 Note If the noise enters the measuring terminals it may cause the display to widely fluctuate or the auto range action to be unstable Ensure to use the shielded wire and connect the shield side to the S...

Page 8: ...tio display Make a connection of the cable to the analog output terminal applying the cable end treatment as the Fig 3 4 1 shows Push down the release knob with a screwdriver or else and insert the cable to the terminal Length to cut 9 10mm Applicable cable AWG28 AWG32 Fig 3 4 1 Data output 0 3VDC 0 display 0V 30000 display 3 000V Conversion system D A conversion system Resolution 1mV Accuracy Acc...

Page 9: ...over of VEW Every time the VEW key is pressed the display changes over To display the resistance value and resistance comparator Rr mode Select the Rr display with VEW key Rr mode To display the voltage value and voltage comparator Vv mode Select the Vv display with VEW key Vv mode To display the resistance and voltage value RV mode Select the RV display with VEW key RV mode GO Ω M OHM V Ω AUTO No...

Page 10: ...ltage comparator Low limit value Turn off Lit up RV mode Resistance measurement value Voltage measurement value Turn off Turn off Lit up Table 3 6 1 3 6 2 Selection of ratio display To changeover the ratio display and the resistance display Changeover of function Every time the FUNC key is pressed the resistance measurement and the ratio display alternate with each other In the resistance measurem...

Page 11: ...l range The range is fixed range in between 30mΩand 3kΩ The lamp of selected range is lit up Selection of manual range Every time the RANGE key is pressed the range lamp changes Selected the required range 3 8 Changeover of voltage range The measuring range of the voltage measurement is selected The operation is not allowed in the memory mode ONLINE or HOLD status Selection of voltage measurement ...

Page 12: ...t up and enters into the zero adjustment condition Cancellation of it can be done by pressing the 0 ADJ key again 3 9 2 Remote operation While the 0 ADJ pin and COM of the REMOTE connector on the rear panel is short circuited the 0 ADJ lamp is lit up and the zero adjustment is in operable condition The measured resistance data at the moment when the 0 ADJ pin is short circuited is memorized as zer...

Page 13: ...urce frequency Otherwise the accurate measurement can not be performed 3 12 Setting of voltage limiter By setting the voltage limiter to ON it is possible to limit the voltage applied to the sample to be measured at the peak of 20mV It protects the destruction of the oxide layer at the contact of the sample to be measured The operation is not allowed in the memory mode ONLINE or HOLD status When n...

Page 14: ...nd the output is retained 3 13 1 Condition of comparison Resistance comparator Display value High limit value HI SET HI output High limit value HI SET Display value Low limit value LO SET GO output Display value Low limit value LO SET LO output Note The comparator makes the comparison including the range Example In case that the high limit value is set to 100 00mΩ 300mΩ range and when 10 00Ω is di...

Page 15: ...e VEW key Refer to the article 3 6 Setting of high limit value Press the SEL key The highest digit of HI SET display blinks Set the numeral with the or key The selected digit blinks with the key Setting of low limit value Press the SEL key The highest digit of LO SET display blinks Set the numeral with the or key The selected digit blinks with the key Setting of comparator range Set with the RANGE...

Page 16: ...position of decimal point being lit up 5V range Decimal point at 104 is lit up 50V range Decimal point at 103 is lit up Note The decimal point automatically changes depending upon the range Finish of the setting The setting can be finished by pressing the SEL key during the setting of low limit Note When the setting of high or low limit is out of the range Err is displayed for a while at the setti...

Page 17: ...NGE SEL VEW BUZZER 3Ω 30Ω 300Ω 3kΩ FL 300mΩ 30mΩ S HI 0 ADJ SHIFT LOCK HI SET LO SET REF V RATIO ONLINE Ω OHM V Ω AUTO No COMP SET MAN L Δ V RANGE SEL VEW BUZZER 3Ω 30Ω 300Ω 3kΩ FL 300mΩ 30mΩ S HI 0 ADJ SHIFT LOCK HI SET LO SET REF V RATIO ONLINE V OHM V Ω AUTO No COMP SET MAN L Δ V RANGE SEL VEW BUZZER 3Ω 30Ω 300Ω 3kΩ FL 300mΩ 30mΩ S HI 0 ADJ SHIFT ONLINE LOCK HI SET LO SET REF V RATIO V OHM V Ω ...

Page 18: ... resistance judgement is GO Buzzer sounds when the resistance judgement is HI Buzzer sounds when the resistance judgement is LO Buzzer sounds when the resistance judgement is HI or LO Buzzer sounds when the voltage judgement is PS Buzzer sounds when the voltage judgement is FL Buzzer sounds when the resistance judgement is GO and the voltage measurement is PS Buzzer sounds when the resistance judg...

Page 19: ...n the front panel Enter the memory mode Press the SHIFT key The SHIFT lamp is lit up Press the MAN L MEM key and the mode changes to the memory mode displaying the memory number The MAN L lamp turns off Call up of memory Press the SEL key then the memory number changes and the content of the selected memory is called up The measurement and judgement are carried out under the measurement conditions...

Page 20: ... memory mode Enter the memory mode Enter the memory mode with the SHIFT and MAN L MEM key Refer to the article 3 16 Setting of memory Press the SHIFT key and the SHIFT lamp is lit up Press the SET key then the display mode blinks on the measurement display and the memory number blinks Selection of memory No Select the memory No pressing the key Selection of display mode Select the display mode set...

Page 21: ...lect the measuring range with the RANGE key The selected range is indicated on the main display section AUTO range can not be set Setting of comparator Press the SEL key and the highest digit of the HI SET blinks to make the comparator setting Refer to the article 3 13 3 Finish Press sequentially the SHIFT key and the SET key then the memory setting finishes and the meter returned to the measureme...

Page 22: ...nnect or short circuit the sample to be measured to the tip of the measuring lead Start of detection of disconnection Short circuit the SW input on the REMOTE connector to COM The measurement display shows Result of detection of disconnection When there is no error detected is displayed on the display section When the disconnection is detected the following displays are given Disconnection of SOUR...

Page 23: ...on of disconnection and self check are started 6 EOC output Transistor output becomes ON when the AD conversion is finished 7 CC ERR output When the current does not flow due to the opening etc of SOURCE terminal and when the error is detected in the detection of disconnection self check the transistor output is made ON 8 COM Common for input and output 9 10 11 12 13 M SEL0 M SEL1 M SEL2 M SEL3 M ...

Page 24: ...e Make an input of the code 1 30 Input the code of memory No and call up the memory Table of memory code Signal Weight 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 M SEL0 1 M SEL1 2 M SEL2 4 M SEL3 8 M SEL4 16 Signal Weight 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 M SEL0 1 M SEL1 2 M SEL2 4 M SEL3 8 M SEL4 16 Makes ON Blank Turns OFF Note The input of 0 or 31 makes no change Turn the MEM signal OF...

Page 25: ...28ms M 90 170ms 70 143ms S 570 650ms 485 540ms 2 Zero adjustment 15ms 5ms 5ms or more Tsh Tsh Tsh S0 Sampling RESET HOLD TRG EOC Input CC ERR Display OFF ON Connection Open OFF ON OFF ON OFF ON OFF ON S1 S2 S3 S4 S5 S6 S7 S0 S1 S2 S4 S5 S6 2ms 2ms 15ms 5ms or more S1 Sampling HOLD Display OFF ON S2 S3 S4 S6 S7 S1 S1 S2 S1 S3 S4 S6 S4 S5 O ADJ OFF ON S0 1ms ...

Page 26: ...F Sampling rate M Sampling rate S 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz T1 48ms 48ms 250ms 250ms 250ms 250ms T2 13 36ms 12 28ms 90 170ms 78 143ms 570 650ms 485 540ms T1 T2 61 84ms 62 76ms 340 420ms 328 393ms 820 900ms 735 790ms Connection HOLD TRG EOC Comparator CC ERR BCD OFF ON OFF ON OFF ON OFF ON T1 T2 OFF ON Sampling MEM HOLD Function EOC OFF ON Ts 6ms 8ms M SEL 0 4 Range ...

Page 27: ...rear panel to the COM terminal the comparator output is reset and the comparator display is turned OFF One sampling hold action It is possible to do the one sampling hold with the HOLD being short circuited and making ON OFF of the RST Do the one sampling hold with the manual range In case of the auto range it may cause an error 3 Comparator output Open collector output HI GO LO all sink type 30V ...

Page 28: ...GE key is pressed the measuring range changes In the auto range AUTO lamp and the detected measuring range are lit up The decimal point is automatically lit up depending upon the selected range Make the setting of comparator Refer to the article 3 13 3 Connect the sample to be measured to the resistance measuring cable then the measured resistance value is displayed In case that the measured resis...

Page 29: ...When the ratio display is selected RATIO on the function display is lit up OHM is turned off At this moment the main display section displays the calculated ratio value and the measuring unit is lit up The referential resistance value is displayed on the HI SET and the deviation is displayed on the LO SET In the ratio display the main display section and the lowest digit of the LO SET are turned o...

Page 30: ...tial resistance value with the RANGE key Adjustable range 00000 35000 Setting of deviation Press the SEL key The highest digit of the deviation display section blinks Set the numeral with the and key The digit selected with the key blinks Adjustable range 0 0 199 9 Finish Press the SEL key Note When the content tried to be set is out of the adjustable range the Err is displayed for a while at the ...

Page 31: ... over range In case of the auto range the range goes up when exceeded the 50000 Also the range goes down when the value becomes 1000 or less Examples of range display At 50V range At 5V range 5 4 Character display Display Name Explanation Error 0 When the measurement is over range Error SO At SOURCE open disconnection being detected Error SE At SENSE open disconnection being detected Set Setting o...

Page 32: ... meter from the front of the panel and fix it to the panel with the fixing metal Note In case that the meter is installed to the chassis utilizing the bottom screw taps of the meters keep the length of screw at 6mm thickness of chassis mm 6 2 External dimensions when fitted with panel mount bracket Panel mount bracket Fixing metal Foot M4 15 flat screw Meter 64 230 169 2 6 20 MODEL 3566 Side view ...

Page 33: ...sistor to suit each range By pressing the ZERO is calibrated and MAX by pressing the key Calibrate each range selecting it by RANGE key When the calibration is properly made is displayed in blinking on the display section for a while If the is displayed it is exceeding the range which can be calibrated Connect a right resistor The standard resistance value and their display value to connect each r...

Page 34: ... 2 2 shows Range ZERO calibration voltage Max calibration voltage 5V 0 0000V 5 000V 50V 0 0000V 50 000V Table 7 2 2 When the calibration is finished turn OFF the power supply and cancel the calibration mode When the meter is powered ON again it returns to measurement 7 2 3 Calibration of analog output The analog output is calibrated in the resistance measurement Press the VEW key to make the Rr mo...

Page 35: ...tion Accuracy Defined at 23 5 45 75 RH For the accuracy of MEDIUM sampling rate a 3 digit is to be added Resistance measurement At FAST sampling Measuring range 30mΩ 300mΩ 3Ω 30Ω 300Ω 3kΩ Resolution 10μΩ 100μΩ 1mΩ 10mΩ 100mΩ 1Ω Measuring current 7 4mA 1mA 100μA 10μA 5μA 1 5μA Accuracy Note 1 0 5 of rdg 6 digit Temperature coefficient Note 2 0 05 of rdg 0 6 digit Open terminal voltage Peak 20mV or ...

Page 36: ...es Output voltage 0 3 000V with digital display 0 30000 3000 digits Conversion system D A conversion system Output accuracy Accuracy of resistance measurement 0 2 F S Note During the ratio display the measured resistance value is output During the setting of standard resistance value in the ratio display function the output is retained Insulation resistance Terminal blocks in a lump Housing 500VDC...

Page 37: ... following interfaces are prepared For the handling of each interface please refer to the instruction manual of respective interface 1 GP IB interface board Model 5811 01A 2 Printer interface board Model 5811 02A 3 BCD data output board TTL Model 5811 03A 4 BCD data output board open collector Model 5811 04A 5 RS 232C interface board Model 5811 05A 6 RS 485 interface board Model 5811 06A Others Ke...

Page 38: ...I 01548 TSURUGA ELECTRIC CORPORATION Instruction Manual Interface of BCD Data Output MODEL 5811 03A 04A for Model 3566 ...

Page 39: ...UNIT 5 3 1 3 Decimal point output DP1 DP4 5 3 1 4 Polarity output POL 5 3 1 5 Over range output OVER 5 3 1 6 Strobe output STROBE 5 3 2 Input signal 6 3 2 1 Data enable OUTPUT ENABLE 6 3 2 2 External hold input HOLD 6 3 2 3 Data select input SEL 6 3 3 4 External control input INT EXT 7 3 3 5 Function input FUNCTION 7 3 3 6 Range input RANGE 7 4 Operation 8 4 1 Resistance measurement 8 4 2 Ratio di...

Page 40: ...d output 1 1 Model 5811 03A 3566 03 BCD data is output by TTL level Output system BCD parallel code positive logic Outputs L level with logic 0 and H level with logic 1 Input Output Input level IIL 1mA Output level TTL level L 0 8V or less Fo 2 H 3 5 5V 1 2 Model 5811 04A 3566 04 BCD data is output by open collector Output system BCD parallel code Outputs OFF with logic 0 and ON with logic 1 Input...

Page 41: ...1 2 10 35 2 4 11 36 4 102 8 12 37 8 103 104 1 13 38 POL OUTPUT ENABLE 14 39 OVER HOLD 15 40 STROBE 104 4 16 41 1 DP2 17 42 2 DP3 18 43 4 SEL DP4 19 44 2 104 1 20 45 1 2 21 46 2 4 22 47 4 RANGE FUNCTION 8 23 48 INT EXT 24 49 NC DATA COM 25 50 DATA COM Connector Anphenol 57 30500 Note Do not use the NC pins as they are connected to the internal circuit 25 50 26 1 ...

Page 42: ...lay DP4 DP3 DP2 350 00 350 0 1 1 0 35 000 35 00 50 000 50 00 1 0 1 3 5000 3 500 5 0000 5 000 0 1 1 3 1 4 Polarity output POL 1 is output at positive plus polarity 0 is output at negative minus polarity 3 1 5 Over range output OVER Error 0 When the measurement data has exceeded 35000 3500 or the voltage measurement data has exceeded 50000 5000 OVER becomes 1 and the data 00000 is output Error 3 Whe...

Page 43: ...sometimes be different Note 2 The display does not change even if the data select is done Data select procedure Make an input of the select code in the table and select the necessary data Table of data output and select code Select code 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 Function L L L L L H L H L L H H H L L H L H H H L H H H At resistance measurement VOLT OHM OHM OHM OHM OHM OHM OHM...

Page 44: ...g an input of the function code make the INT EXT input L level in advance Function 8 4 2 1 Resistance measurement H L L H Ratio display L H H H Note The setting other than the above is invalid 3 2 6 Range input RANGE By making an input of a range code the resistance range can be externally selected When making an input of the range make the INT EXT input L level in advance RANGE 4 2 1 Range L L L ...

Page 45: ...istance value make the INT EXT H level and set with the switch on the front panel Select the resistance range with the range RANGE Input the OHM RATIO or T C RATIO code range code to the function FUNCTION OHM RATIO Displays the ratio in the resistance measurement T C RATIO Displays the ratio in the temperature compensation Start the measurement 5 Timing chart 5 1 Data output Tsh Ts 3ms Ts Sampling...

Page 46: ...9 5 2 Timing chart for changeover of function H INT EXT L SAMPLING FUNCTION 5V OFF STROBE 0V ON RATIO data OHM data DATA OUT RATIO OHM ...

Page 47: ...I 01680 TSURUGA ELECTRIC CORPORATION Instruction Manual Interface of BCD Data Output MODEL 5811 03D 04D for Model 3568 ...

Page 48: ...y output POL 4 3 1 5 Over range output OVER 4 3 1 6 Strobe output STROBE 4 3 2 Input signals 5 3 2 1 Data enable OUTPUT ENABLE 5 3 2 2 Remote hold input HOLD 5 3 2 3 Data selection input SEL 5 3 2 4 Remote control input INT EXT 6 3 2 5 Input of function FUNCTION 6 3 2 6 Range input RANGE 7 4 Operation 8 4 1 Resistance measurement 8 4 2 Temperature measurement 8 4 3 Temperature compensation 8 4 4 R...

Page 49: ... 1 1 MODEL 5811 03D 3568 03 BCD data is output by TTL level Output system Parallel BCD code positive logic L level is output by logic 0 and H level by logic 1 1 2 MODEL 5811 04D 3568 04 BCD data is output by open collector Output system Parallel BCD code OFF is output by logic 0 and ON by logic 1 Input Input 5V CMOS 0V Input level IIL 1mA L 0 8V or less H 3 5 5V Output Output 5V CMOS Output level ...

Page 50: ...9 34 1 2 10 35 2 4 11 36 4 102 8 12 37 8 103 104 1 13 38 POL OUTPUT ENABLE 14 39 OVER HOLD 15 40 STROBE DP1 16 41 1 DP2 17 42 2 DP3 18 43 4 SEL DP4 19 44 2 104 1 20 45 1 2 21 46 2 4 22 47 4 RANGE FUNCTION 8 23 48 INT EXT 24 49 NC DATA COM 25 50 DATA COM Connector Anphenol 57 30500 Note Do not use NC pin as it is connected to the internal circuit 25 50 26 1 ...

Page 51: ...ange output OVER Error 0 When the data exceeded 35000 3500 or the measured temperature exceeded the measuring range in temperature measurement OVER becomes 1 and the data 00000 is output Error 1 When the data exceeded the temperature measuring range in temperature compensation function and temperature conversion function OVER becomes 1 and the data 00001 is output Error 2 When the calculation is f...

Page 52: ...able and select the necessary data Table of data output selection code 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 4 2 1 Selection code Function L L L L L H L H L L H H H L L H L H H H L H H H At resistance measurement OHM OHM OHM OHM OHM OHM OHM OHM At temperature measurement TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP At temperature compensation Err3 Rt t Err3 Err3 Err3 Err3 RT At ratio display Err3 R...

Page 53: ... no range can be selected 3 2 5 Input of function FUNCTION By designating a function code each function can be remote controlled When inputting the function code do it after setting INT EXT input to L level Function 8 4 2 1 Resistance measurement H L L H Temperature measurement H L L L Temperature compensation L H L L OHM RATIO L H H H Ratio display T C RATIO L H L H Te CLR L L H H T1 L L H L T2 L...

Page 54: ... 1 Range L L L Resistance measurement Auto range L L H Resistance measurement 300mΩ L H L Resistance measurement 3Ω L H H Resistance measurement 30Ω H L L Resistance measurement 300Ω H L H Resistance measurement 3kΩ H H L Resistance measurement 30kΩ H H H Resistance measurement 300kΩ Timing chart for switching over of range STROBE 1 2 3 1 2 3 RANGE input Change over internal range INT EXT ...

Page 55: ...L level Note 1 Setting of standard temperature and temperature coefficient Make the remote control input INT EXT H level and set with the switch on the front panel Select a resistance range with the range RANGE Input a temperature compensation code to the function FUNCTION Start measurement 4 4 Ratio display Refer to the article 5 5 of this manual Make the remote control input INT EXT L level Note...

Page 56: ...t the T E code T E END is displayed Temperature increase at input is memorized as Te Read out of each data After the finish of temperature conversion the data T1 T2 R1 R2 and TE of each channel is output Note 1 Perform the measurement separately from the conductance test If the test sample is in the condition being conducted the measurement can not be made Note 2 Zero adjustment function can not b...

Page 57: ...nction HOLD MAX 3ms DATA OUT STROBE t Tsh Tsh Ts 1 2 3 4 5 0 1 3 4 0 1 3 5 INT EXT SAMPLING 5V OFF 0V ON RST COMPARATOR OUTPUT ENABLE H L DATA OUT FUNCTION OHM Ts T C OHM data T C data STROBE INT EXT SAMPLING 5V OFF 0V ON H L Contact Information Name Tsuruga Electric Corporation Address 1 3 23 Minami Sumiyoshi Sumiyoshi ku Osaka shi 558 0041 Japan ...

Page 58: ...I 01549 TSURUGA ELECTRIC CORPORATION Instruction Manual Interface of RS 232C MODEL 5811 05A for Model 3566 ...

Page 59: ...COMPV setting of comparator 12 4 2 11 COMPR COMPV read out of comparator data 12 4 2 12 DATA read out of measurement data 13 4 2 13 FUNCTION measuring function 14 4 2 14 FUNC read out of function data 14 4 2 15 HOLD setting of hold 15 4 2 16 HOLD read out of hold status 15 4 2 17 RANGE setting of measuring range 16 4 2 18 RANGE read out of measuring range 16 4 2 19 RATIOSTD setting of standard rat...

Page 60: ...ry Connector Sub D 9 pin male 2 Connection 2 1 Connector and signal Pin No Meter signal JIS RS 232C Direction Name Not in use RD RXD Input Receiving data SD TXD Output Transmission data Not in use SG GND Ground for signal Not in use RS RTS Output Request for transmission CS CTS Input Transmittable Not in use 2 2 Xon Xoff control Soft handshake The transmission is stopped when Xoff is received and ...

Page 61: ...Nil Note Make the setting of the dip switch with the power supply switched OFF 2 5 ONLINE switch By setting the dip switch No 8 on the rear panel to ON side the ONLINE on the front panel is lit up and it is enabled to do a remote control by RS 232C and to read out the data setting The control functions in ONLINE are as follows Setting of each setting parameter is possible Note In the ONLINE status...

Page 62: ...put command is received the designated data is output When the ineffective command is received the Command Error is returned Example In case of effective command FUNCTION OHM Response FUNCTION OHM In case of ineffective command FUNCTION MACHIGAI Response Command Error Higher level Command frame Response frame Command frame Response frame 3566 computer ...

Page 63: ...the 3566 2 Delimiter Code delimiter to inform the 3566 of the finish of transmission data block judged as delimiter when received the 0AH Table of character code 0 1 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N ˆ n F O _ o Blank code is undefined ...

Page 64: ...N OFF ON OFF The setting and control through RS 232C is possible with ON The setting and control through RS 232C is not possible with OFF Note The setting is not possible when the ONLINE is made by the dip switch on the rear 4 2 2 ONLINE read out of online Function The settings of online is read out Structure ONLINE Transmission ONLINE Response ONLINE OFF ...

Page 65: ...esignates the FAIL buzzer GOOD designates the buzzer at GO and PASS buzzer NG designates the buzzer at HI LO or FAIL buzzer Note Either one of the buzzer setting is possible Data Designates the buzzer sound volume Sound volume can be set in 9 steps 01 10 Note When the setting is buzzer OFF the designation for buzzer sound volume is disregarded Transmission Set GOOD buzzer sound level to 3 BUZZ GO ...

Page 66: ...t the memory mode manual mode Structure MODE Transmission MODE Response MODE MANUAL Mode setting data data length 6 4 2 7 MEM CALL call up of memory Function The memory designated by the No is called up Note Make the setting after changing to the memory mode Structure MEM CALL No MEM Memory number setting command No Designate the memory 01 30 Transmission Designates to the memory No 01 and works a...

Page 67: ... the display mode data length 8 Shows the resistance measurement function data length 10 Shows the resistance measurement range data length 7 Shows the HI data of resistance comparator data length 12 Shows the LO data of resistance comparator data length 12 Shows the voltage measurement range data length 3 When the resistance range is set to AUTO the voltage measurement also works in the auto rang...

Page 68: ...djustable range of numeral 0 35000 VOLT Voltage range 5V 50V VH HI SET High limit value data of the voltage comparator Adjustable range of numeral 50000 VL LO SET Low limit value data of the voltage comparator Adjustable range of numeral 50000 Note 1 RH HI SET and RL LO SET are to be set adding the unit and decimal point Example of setting 35 000kOHM Note 2 When the FUNC is RATIO HI SET Standard v...

Page 69: ...voltage comparator to 15 000V and the LO SET to 2 000V COMPV VH 15 000V VL 02 000V Note The setting is not possible in the memory mode The setting of the resistance comparator is not possible when the measuring function is RATIO ratio display 4 2 11 COMPR COMPV read out of comparator data Function Read out the high and low limit value of the comparator Structure COMPR Read out of the resistance co...

Page 70: ...JUDGE FAIL Shows the ratio data data length 7 Shows the resistance measurement data data length 13 Shows the ratio standard resistance value data length 14 Shows the resistance judgement output data length 13 Shows the voltage measurement data data length 13 Shows the voltage judgement output data length 12 Note R JUDGE output At GO R JUDGE GO At HI R JUDGE HI At LO R JUDGE LO At HI LO R JUDGE HI ...

Page 71: ...OHM RATIO Ratio display Transmission Set the measuring function to the resistance measurement FUNCTION OHM FUNCTION OHM RATIO 4 2 14 FUNC read out of function data Function Read out the type of measuring function Structure FUNC FUNC Measuring function output command Transmission FUNC Response FUNCTION OHM Shows the function data output data length 9 Shows the measuring function data ...

Page 72: ...ON OFF Stop the sampling and hold the data with ON Designate the cancellation of hold with OFF Transmission Set the hold to ON HOLD ON 4 2 16 HOLD read out of hold status Function Read out the status of hold Structure HOLD Transmission HOLD Response HOLD ON Shows the hold data output Shows the status data of the hold data length 3 ...

Page 73: ...3kΩ To make the auto range set AUTO Table 4 1 Range code Measuring range 30mOHM 30mΩ 300mOHM 300mΩ 3OHM 3Ω 30OHM 30Ω 300OHM 300Ω 3kOHM 3kΩ AUTO Auto range Transmission Set the resistance measurement range to 30Ω RANGE 30OHM 4 2 18 RANGE read out of measuring range Function Read out the setting condition of the measuring range Structure RANGE Transmission RANGE Response RANGE 3 kOHM Shows the range...

Page 74: ...tandard value REF Standard resistance value deviation data 00 0 199 9 Transmission Set the 10 000Ωto the standard resistance value and 20 0 to the deviation RATIOSTD 10 000OHM 20 0 4 2 20 RATIOSTD read out of standard ratio value Function Read the data of ratio standard value Structure RATIOSTD Transmission RATIOSTD Response RATIOSTD 10 000kOHM 020 0 Shows the data output of the ratio standard Sho...

Page 75: ... ON Designate the cancellation of reset with OFF Transmission Rest the comparator judgement output RST ON One sampling hold While the 3566 is in hold status and when the reset is made ON and afterward turned OFF one sampling hold can be done 4 2 22 RST read out of judgement reset status Function Read out the status of comparator judgement reset Structure RST Transmission RST Response RST OFF Shows...

Page 76: ...LOW 1 56 times sec 1 88 times sec MEDIUM 6 25 times sec 7 52 times sec FAST 50 times sec 60 times sec Transmission Set the measuring sampling rate to low speed SAMPLING SLOW 4 2 24 SAMPLING read out of sampling rate Function Read out the status of sampling rate Structure SAMPLING Transmission SAMPLING Response SAMPLING SLOW Shows the sampling data output Shows the status data length 6 ...

Page 77: ...is displayed and output until the ZEROADJ OFF is received Structure ZEROADJ ON OFF ZEROADJ Zero adjustment setting command ON OFF Designate the effect with ON Designate the cancellation with OFF Transmission Set the zero adjustment to ON ZEROADJ ON 4 2 26 ZEROADJ read out of zero adjustment Function Read out the status of zero adjustment Structure ZEROADJ Transmission ZEROADJ Response ZEROADJ OFF ...

Page 78: ...Display mode Display mode setting command Display mode OHM Rr mode VOLT Vv mode OHM VOLT RV mode Transmission Set the display mode to Rr VIEW OHM 4 2 28 VIEW read out of display mode Function Read out the display mode Structure VIEW Transmission VIEW Response VIEW OHM VOLT Shows the display mode data length 8 ...

Page 79: ...I 01550 TSURUGA ELECTRIC CORPORATION Instruction Manual Interface of RS 485 MODEL 5811 06A for Model 3566 ...

Page 80: ...5 2 10 COMPR COMPV setting of comparator 12 5 2 11 COMPR COMPV read out of comparator data 12 5 2 12 DATA read out of measurement data 13 5 2 13 FUNCTION measuring function 14 5 2 14 FUNC read out of function data 14 5 2 15 HOLD setting of hold 15 5 2 16 HOLD read out of hold status 15 5 2 17 RANGE setting of measuring range 16 5 2 18 RANGE read out of measuring range 16 5 2 19 RATIOSTD setting of...

Page 81: ...rs of connectable devices Max 32 devices including the higher level computer Line length Max 500m Device numbering 00 99 set for each device not to duplicate Set with the rear panel switch Terminator Terminates with 200Ω ON OFF changeover with the rear panel switch 2 Connection 2 1 Connection terminals Terminal number 1 2 Signal name A B 2 2 Switch for device numbering Make a setting with the rota...

Page 82: ...ter are possible Read out of the working status and measurement data is possible 3 2 Explanation of communication t response time min 8ms Response frame When the effective setting command is received the content of receipt is returned When the effective output command is received the designated data is output When the ineffective command is received Command Error is returned Example In case of eff...

Page 83: ...H 4EH 47H 45H 3DH 03H 60H 101 100 Response frame Device No STX 1 0 R A N G E 3 O H M ETX BCC 02H 31H 30H 52H 41H 4EH 47H 45H 3DH 33H 4FH 48H 4DH 03H 19H 101 100 BCC BCC is defined as the calculated result of the exclusive logical addition from immediately after STX to ETX including ETX ...

Page 84: ...5 1 Command data JIS punctuation code is used for the command data Example STX 0 1 RANGE 300OHM ETX BCC Device No Command 1 STX Start code 2 Device No 3 Command Command to control 3566 4 ETX Finish code 5 BCC Error detection code ...

Page 85: ...ON OFF ON OFF The setting and control through RS 485 is possible with ON The setting and control through RS 485 is not possible with OFF Note The setting is not possible when the ONLINE is made by the dip switch on the rear 5 2 2 ONLINE read out of online Function The setting of online is read out Structure ONLINE Transmission ONLINE Response ONLINE OFF ...

Page 86: ...GOOD designates the buzzer at GO and PASS buzzer NG designates the buzzer at HI LO or FAIL buzzer Note Either one of the buzzer setting is possible Data Designates the buzzer sound volume Sound volume can be set in 9 steps 01 10 Note When the setting is buzzer OFF the designation for buzzer sound volume is disregarded Transmission Set GO buzzer sound level to 3 BUZZ GO 03 BUZZ OFF When the setting...

Page 87: ...Function Read out the memory mode manual mode Structure MODE Transmission MODE Response MODE MANUAL 5 2 7 MEM CALL call up of memory Function The memory designated by the No is called up Note Make the setting after changing to the memory mode Structure MEM CALL No MEM Memory number setting command No Designate the memory 01 30 Transmission Designates to the memory No 01 and works afterwards as the...

Page 88: ...Shows the resistance measurement function data length 10 OHM Resistance measurement OHM RATIO Ratio display Shows the resistance measurement range data length 7 Shows the HI data of resistance comparator data length 12 Shows the LO data of resistance comparator data length 12 Shows the voltage measurement range data length 3 When the resistance range is set to AUTO the voltage measurement also wor...

Page 89: ...000 VOLT Voltage range 5V 50V VH HI SET High limit value data of the voltage comparator Adjustable range of numeral 50000 VL LO SET Low limit value data of the voltage comparator Adjustable range of numeral 50000 Note 1 RH HI SET and RL LO SET are to be set adding the unit and decimal point Example of setting 35 000kOHM Note 2 When the FUNC is RATIO HI SET Standard value LO SET Deviation are to be...

Page 90: ...et the HI SET of voltage comparator to 15 000V and the LO SET to 2 000V COMPV VH 15 000V VL 02 000V Note In the memory mode no setting is possible in the manual mode and the measuring function is RATIO ratio display 5 2 11 COMPR COMPV read out of comparator data Function Read out the high and low limit value and unit of the comparator Structure COMPR Read out of the resistance comparator COMPV Rea...

Page 91: ...UDGE FAIL Shows the ratio data data length 7 Shows the resistance measurement data data length 13 Shows the ratio standard resistance value data length 14 Shows the resistance judgement output data length 13 Shows the voltage measurement data data length 13 Shows the voltage judgement output data length 12 Note R JUDGE output At GO R JUDGE GO At HI R JUDGE HI At LO R JUDGE LO At HI LO R JUDGE HI L...

Page 92: ...TIO Ratio display Transmission Set the measuring function to the resistance measurement FUNCTION OHM FUNCTION OHM RATIO 5 2 14 FUNC read out of function data Function Read out the measuring function Structure FUNC FUNC Measuring function output command Transmission FUNC Response FUNCTION OHM FUNCTION OHM RATIO Shows the function data output data length 9 Shows the measuring function data ...

Page 93: ...FF Stop the sampling and hold the data with ON Designate the cancellation of hold with OFF Transmission Set the hold to ON HOLD ON 5 2 16 HOLD read out of hold status Function Read out the status of hold Structure HOLD Transmission HOLD Response HOLD ON HOLD OFF Shows the hold data output Shows the status data of the hold data length 3 ...

Page 94: ...3kΩ To make the auto range set AUTO Table 5 1 Range code Measuring range 30mOHM 30mΩ 300mOHM 300mΩ 3OHM 3Ω 30OHM 30Ω 300OHM 300Ω 3kOHM 3kΩ AUTO Auto range Transmission Set the resistance measurement range to 30Ω RANGE 30OHM 5 2 18 RANGE read out of measuring range Function Read out the setting condition of the measuring range Structure RANGE Transmission RANGE Response RANGE 3 kOHM Shows the range...

Page 95: ...istance value deviation data 00 0 199 9 Transmission Set the 10 000Ωto the standard resistance value and 20 0 to the deviation RATIOSTD 10 000OHM 20 0 Note When the FUNCTION is not RATIO Not Control is returned 5 2 20 RATIOSTD read out of standard ratio value Function Read the data of ratio standard value Structure RATIOSTD Transmission RATIOSTD Response RATIOSTD 10 000kOHM 020 0 Shows the data ou...

Page 96: ... ON Designate the cancellation of reset with OFF Transmission Rest the comparator judgement output RST ON One sampling hold While the 3566 is in hold status and when the reset is made ON and afterward turned OFF one sampling hold can be done 5 2 22 RST read out of judgement reset status Function Read out the status of comparator judgement reset Structure RST Transmission RST Response RST OFF Shows...

Page 97: ...of the sampling rate SLOW MEDIUM FAST 50Hz 60Hz SLOW 1 56 times sec 1 88 times sec MEDIUM 6 25 times sec 7 52 times sec FAST 50 times sec 60 times sec Transmission Set the measuring sampling rate to low speed SLOW SAMPLING SLOW 5 2 24 SAMPLING read out of sampling rate Function Read out the status of sampling rate Structure SAMPLING Transmission SAMPLING Response SAMPLING SLOW Shows the sampling d...

Page 98: ...is displayed and output until the ZEROADJ OFF is received Structure ZEROADJ ON OFF ZEROADJ Zero adjustment setting command ON OFF Designate the effect with ON Designate the cancellation with OFF Transmission Set the zero adjustment to ON ZEROADJ ON 5 2 26 ZEROADJ read out of zero adjustment Function Read out the status of zero adjustment Structure ZEROADJ Transmission ZEROADJ Response ZEROADJ OFF ...

Page 99: ...Display mode Display mode setting command Display mode OHM Rr mode VOLT Vv mode OHM VOLT RV mode Transmission Set the display mode to Rr VIEW OHM 5 2 28 VIEW read out of display mode Function Read out the display mode Structure VIEW Transmission VIEW Response VIEW OHM VOLT Shows the display mode data length 8 ...

Reviews: