Summary of Contents for ER2C-04A

Page 1: ...300 0013 Japan TEL 81 29 832 3031 Representative FAX 81 29 832 2662 URL http www tsujicon jp E mail info2 tsuji denshi co jp 4CH 2CH ENCODER COUNTER ER4C 04A User s Manual No 4011 Rev 0 APPLICATION O...

Page 2: ...Specification 1 Panel Layout 2 SETUP Mode 4 Communication Command 5 Firmware Version Up 7 Contents...

Page 3: ...ear Each channel can set by LAN Communication Commands 7 Scaling Can use scaling function significant figures 15 Scaled value pulse count offset multiplier parameter they are set by LAN communication...

Page 4: ...he most significant 7 digit is displayed When the most significant 7 decimal digit include a decimal point the most significant 6 digit is displayed upper scaled value lower preset value can be change...

Page 5: ...oder panel receptacle SRCN2A16 10S JAE cable plug SRCN6A16 10P JAE Line Driver Circuit ex pin4 5 pin6 7 and pin8 9 are same as pin4 5 Termination is selectable in SETUP mode When line driver input and...

Page 6: ...all LCD return to NORMAL mode Encorder Counter starts runnig in a new setting except for LAN IP 1 LAN IP 2 and Port no If you change those setting value turn off POWER ON SW after the display returns...

Page 7: ...sition counter preset must be in within 10digit If the value is over the range maximun or minimum value is set VER 1 00 20 10 06 ER4C 04A Firmware version read request in case of Ver 1 00 FROM FROM0 o...

Page 8: ...tiplier setting channel A D must be in the format range 0 000001 999 999999 MR M Scaling Parameter multiplier read request OW Scaling Parameter offset setting channel A D must be in within 10 digit ra...

Page 9: ...ck File Snd button Then version up software starts sending While Encorder Counter is receiving the file SETUP SW will blink slowly When Encorder Counter finishes receiving SETUP SW will blink fast and...

Page 10: ...W SETUP SW will blink and go out Turn off POWER ON SW again and set DSW1 s switch1 off Turn on POWER ON SW again Encorder Counter will run using firmware version 1 00 Then try update again by using ne...