1
Tsubaki
Cableveyor
®
ᴾ ᴾ ᴾ
1. Cableveyor Assembly
1-1.
Connect any disconnected links and attach the
arms to the hinge side of the link
Caution: Once the disconnected links are connected
and the Cableveyor is installed, determine
which direction the arms will open the easiest
before attaching.
1-2.
Fix the locking hook.
Push in the arms from above by hand. Hold the
entire arm down and lightly tap in the locking
hook head from the side with a plastic hammer.
2. Cableveyor Disassembly
2-1. Release the locking hook
Release the locking hook using a screwdriver and
remove the arm from the link.
Caution: Insert the screwdriver tip and release the locking hook as shown in the following diagram. Facing the
screwdriver in a different direction or forcefully inserting it may result in Cableveyor breakage.
Use a screwdriver with a 4.5mm or
smaller tip.
TKP68H46
(formerly TKP0680)
User Manual
Link
Arm
Locking
hook
Caution: Always wear the appropriate protective gear (safety glasses, gloves, safety shoes,
etc.) when working.