TSM Optimix Initial Setup Download Page 4

 

TSM Control Systems, 

Ard Easmuinn,  
Dundalk, Co. Louth, Ireland 
Tel: (+353) 42-9335560  Fax: (+353) 42-9334422 
Email:   [email protected] 
Website: www.tsm-controls.com  

 

 

 

 

 

Remove weight from hopper. ‘Weight (Kg)’ should now return to 

zero. 

 

 

 

 

The ideal batch weight will be 
factory set. 

If it is necessary the batch weight 
can be changed inside the 
engineering section. 

 

 

 

 

Upon sucessful completion , procede to enter the first recipe name and setpoints. 

 

 

Use 

 to exit to “calibration Menu” & save settings or   to go to the home 

screen. 

 

Blender 

Type 

Recommended  

Batch size 

Load cell 

Max weight 

Optimix 

0.7Kg/1.5lb 

5kg 

TSM350 

2Kg/4.5lb 

10 Kg 

TSM650 

3Kg/6.5lb 

10 Kg 

TSM1000 

5Kg/11lb 

20 Kg 

TSM1600 

7Kg/15lb 

20Kg 

TSM3000 

25Kg/50lb 

40 Kg 

 

Doc no TD 107 Rev 1.1 

 