TSL Tally Man PSU-22 Manual Download Page 1

 

 

UMD PSU-22 

V4.0 

 

 

 

 

 

 

 

 

 

 

The TSL Tally and  

UMD Configuring Program

 

 

Power Supply PSU-22 

– this section is intended to be read in conjunction with the 

Introduction

 

 

 

 

Television Systems Limited.

 

Vanwall Road, Maidenhead, Berkshire, SL6 4UB 

Tel44 (0)1628 676200, FAX +44 (0)1628 676299 

Summary of Contents for Tally Man PSU-22

Page 1: ...UMD Configuring Program Power Supply PSU 22 this section is intended to be read in conjunction with the Introduction Television Systems Limited Vanwall Road Maidenhead Berkshire SL6 4UB Telephone 44...

Page 2: ...particular consideration must be given to the stability of free standing racks by mounting heavy equipment low in the rack The rear of the unit should be supported in the rack Power For pluggable equ...

Page 3: ...the unit A contact name and telephone number are also required with the Fault Report sent with the unit Fault report details required Company Name Address Contact Name Telephone No Returns Number Sym...

Page 4: ...andards Declared EN 50081 1 EN 50082 1 Manufacturer s Name Television Systems Ltd Manufacturer s Address Vanwall Rd Maidenhead Berks SL6 4UB Type of Equipment Under Monitor Display Power Supply Unit M...

Page 5: ...n 2 0 Description 3 0 Operation 4 0 Connection Details on the Hardware 5 0 Specifications 6 0 The Internal Power Supplies 7 0 General Notes WARNING Disconnect power before removing the covers There ar...

Page 6: ...PSU1 fitted to the LH frame and the top IEC is the power inlet connector This unit can provide a maximum of 96 PLU power loading units where one PLU is equivalent to 2 5 Watts Note that a maximum of...

Page 7: ...Man Controller TM1 The input RJ45 serial port on the rear of the PSU 22 is fed from any TM1 Display Port which could be located at some distance away up to 200m from the monitor stack 4 0 Connection D...

Page 8: ...The D25 Connector This socket carries GPI alarm o p information In the good position the relays are energised The table shows the unit in the good position with all modules fitted Pin out is as follo...

Page 9: ...er 240W Twin internal PSUs both IEC connectors Width 483mm Height 88mm Depth 400mm Weight 6 6Kgm Input Power 300W Operating Temp 5 25 C Output Power 240W The depth figures do not include connector dep...

Page 10: ...ery Over Voltage Protection 27 6 32 4V Fan Control Over Temp Protect RTH1 or RTH2 50 C Fan On 45 C Fan Off 70 C Output Shutdown Temp Coefficient 0 03 C 0 50 C Setup Rise Hold up Time 1 5s 50ms 20ms Vi...

Page 11: ...his is to allow products such as the ML1 which draws approx 800mA to be powered along with a combination of the standard displays up to a maximum of 240W 4 For RJ 45 connected TSL equipment the pin ou...