AMU2-BHD+-6
7
ISSUE 6
2)
Pressing select a second time gives:
D
I
S
P
B
A
R
All the LEDs are lit up to the highest level displayed.
Pressing the change button gives:
D
I
S
P
D
O
T
Only the highest level LED is lit.
3)
Pressing select a third time gives:
R
S
P
N
1ms
Pressing the change button gives:
.1ms
This changes the response for the relevant scales.
(0.1ms,1ms, 5ms 10ms, and VU integration times.)
4)
Pressing select a fourth time gives:
I
D
0
O
N
This enables the unit to display the reference markers which are nominally set to
0dB. These are set as follows for the appropriate scales fitted: PPM 4 for UK,
TEST for EBU, - 4 for VU, - 6 for DIN, 0 or Test for Nordic, -18dB or - 20 dB for
Digital.
When the
change
button is depressed the markers are not displayed and an
OFF indication is displayed in the lower display.