Supplying Power to the Model 5725 

The Model 5725 V

ELOCI

C

ALC

 Air Velocity Meter

 

is powered with four size 

AA batteries. 

Installing the Batteries 

Insert four AA batteries as indicated by the diagram located on the 
inside of the battery compartment. The Model 5725 is designed to 
operate with either alkaline or NiMH rechargeable batteries, although it 
will not recharge NiMH batteries. Battery life will be shorter if NiMH 
batteries are used. Carbon-zinc batteries are not recommended because 
of the danger of battery acid leakage. 

Using the Optional AC Adapter 

When using the AC adapter, the batteries (if installed) will be bypassed. 
Be sure to provide the correct voltage and frequency, which is marked 
on the back of the AC adapter. The AC adapter will not recharge the 
batteries. 

Attaching the Handle 

To attach the handle, screw the handle into the bottom of the rotating 
vane head until secure. Remove the handle after use to prevent damage 
to either the head or the handle. 

Using the Optional Articulating Extension 

The articulating extension allows you to secure the vane head at nearly 
any angle. Once you have attached the articulating extension, you can 
unscrew the swivel adjustment bolt, and adjust the angle of the elbow. 
You can then adjust the pivot position of the head by partially 
unscrewing the head from the handle and tightening it with the knurled 
knob, located underneath the vane head. 

Connecting to a Computer 

Use the Computer Interface USB Cable provided with the Model 5725 to 
connect the instrument to a computer for downloading stored data or for 
remote polling. Connect the end labeled “COMPUTER” to the computer 
USB port and the other end to the data port of the Model 5725.

 

Then run the 

LogDat2 downloading software. Within the LogDat2 software, either select 
the tests to be downloaded or double-click on a test to open it. 

Summary of Contents for VELOCICALC 5725

Page 1: ...Ventilation Testing VELOCICALC Air Velocity Meter Model 5725 Operation and Service Manual ENERGY AND COMFORT...

Page 2: ...rranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE TO THE EXTENT PERMITTED BY LAW THE EXCLUSIVE...

Page 3: ...Using the Optional Articulating Extension 3 Connecting to a Computer 3 CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 SETTINGS 6 FLOW SET UP 6 DATA LOGGING 6 Measurem...

Page 4: ......

Page 5: ...ack the instrument and accessories from the shipping container Check the individual parts against the list of components below If anything is missing or damaged notify TSI immediately 1 Carrying case...

Page 6: ......

Page 7: ...he handle screw the handle into the bottom of the rotating vane head until secure Remove the handle after use to prevent damage to either the head or the handle Using the Optional Articulating Extensi...

Page 8: ...ata see Chapter 3 section titled LogDat2 Downloading Software Caution This symbol is used to indicate that the data port of the Model 5725 is not intended for connection to a public telecommunications...

Page 9: ...e used in different places The following is a brief explanation of the meanings of those terms Sample Consists of all of the measurement parameters stored at the same time Test ID A group of samples T...

Page 10: ...soft keys to scroll through the settings for each option and use the key to accept settings FLOW SET UP In Flow Setup mode there are 3 types Round Duct Rectangle Duct and Duct Area Use the g or h soft...

Page 11: ...clear memory and reset the memory available LogDat2 Downloading Software The Model 5725 comes with special software called LogDat2 Downloading Software which is designed to provide you with maximum f...

Page 12: ......

Page 13: ...824 The Model 5725 can also be recalibrated in the field using the CALIBRATION menu These field adjustments are intended to make minor changes in calibration to match a user s calibration standards Th...

Page 14: ......

Page 15: ...unit on Low or dead batteries Replace batteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less t...

Page 16: ......

Page 17: ...ating Electronics 40 to 113 F 5 to 45 C Operating Vane Head 32 to 140 F 0 to 60 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Altitude up to 4000 meters Relative humidity up to 80 RH...

Page 18: ...14 Appendix A Power Requirements Four AA size batteries included or AC adapter optional 9 VDC 300 mA 4 18 watts input voltage and frequency vary depending on which adapter is used...

Page 19: ...i com Website www tsiinc fr Germany Tel 49 241 523030 E mail tsigmbh tsi com Website www tsiinc de Sweden Tel 46 8 595 13230 E mail tsiab tsi com Website www tsi se India Tel 91 80 41132470 E mail tsi...

Reviews: