TSI Instruments AeroTrak 9110 Series Quick Start Manual Download Page 7

 

-7- 

Reviewing Data 

1.  Use the 

Data

 screen to review data that has been 

collected. Use the scroll bar (slide) on the right to 
scroll though the records.  

 

2.  The record number is displayed near the bottom of 

the screen. As each record is selected, its data and 
relevant parameters are displayed. 

3.  Descriptions of each section of the data display 

screen are given in the following table. 

 

Data Screen Labels and Controls 

Field 

Description 

#, ft

3

, m

3

 

Button used to change between counts and 
concentration displays. 

Size 

 

Channel size. 

 

Differential concentration. 

  

Cumulative concentration. 

 

Export the data to a flash drive.  

 

Print data to the optional printer.  

Zone  (Z) 

Zone in which the data was collected. 

Location (L) 

Location within the Zone. 

Date 

Date on which the data was collected. 

Time 

Time at which data collection was initiated. 

Sample 

Duration of the sampling period. 

Vol 

Volume of air that was sampled. 

Alarm 

Alarm threshold was triggered (Yes) or not 
(No). 

Inst 

Status of the instrument hardware. 

OK

 if no 

issues or an error abbreviation if instrument 
has a possible issue. 

Temp 

Temperature at the end of the time the data 
was collected (if optional probe was 
connected during sampling). 

Data Screen Labels and Controls 

Field 

Description 

RH 

Humidity level at the end of the time the data 
was collected (if optional probe was 
connected during sampling). 

Vel 

Velocity of the ambient air at the sampling 
location as measured by a connected TSI 
Velocity probe (optional).  

Record 

The record number of the sample being 
displayed. 

Records 

Total number of records. 

Instrument Configuration 

Select the 

Setup

 tab page and tap the 

Device

 button to 

get to the Device Setup page from which you can 
access screens that allow you to set or change the date 
and time, calibrate the touchscreen display, set up 
communications, make regional selections, or get to the 
Service screen.  
 

 

 

 

Summary of Contents for AeroTrak 9110 Series

Page 1: ...AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE P N 6004346 REVISION K MARCH 2018 ...

Page 2: ... controls adjustments or procedures other than those specified in this manual may result in exposure to hazardous optical radiation C A U T I O N The shipping containers and packaging provided with your particle counter are specially designed to protect the instrument Please retain the packaging for shipping the instrument for service or calibration Use of other packaging may result in damage to t...

Page 3: ...hat is not a clean room This will prevent contaminating the optics that will then require cleaning Note For zero checking in a dirty environment two filters in series may be needed 2 Remove the battery door in the back of the instrument see picture below with the two thumb screws and install one or more batteries doesn t matter which slot 3 Connect the appropriate power cord to the universal power...

Page 4: ... particle counter including data display system configuration device sampling and Recipes 8 Use the Data screen to review data that has been collected 9 Use the Reports screen to select various standard reports for viewing and printing 10 The screens and their options are explained in detail in the Operation Manual Using the Onscreen Keyboard 1 Throughout the setup screens a keyboard will appear o...

Page 5: ...rganization used by the supported classification standards where a zone or room is classified by measuring samples at various locations within that zone If the instrument is not being used for standard classification it is still a good practice to group sample data by Zone because it is easier to select the grouped data for printing and export and it helps to annotate exported sample data by relat...

Page 6: ...mber of samples for each data collection period is chosen Channels allow for channels to be enabled disabled and alarm levels to be chosen 9 Timing field details are provided below Field Description Start Delay Start Delay indicates how long it will be before the first sample is taken NOTE It takes approximately 10 seconds for the pump to reach the flow set point taking a measurement before the pu...

Page 7: ...le Duration of the sampling period Vol Volume of air that was sampled Alarm Alarm threshold was triggered Yes or not No Inst Status of the instrument hardware OK if no issues or an error abbreviation if instrument has a possible issue Temp Temperature at the end of the time the data was collected if optional probe was connected during sampling Data Screen Labels and Controls Field Description RH H...

Page 8: ...USB IP address and date and time format Service Screen This screen is for use when cleaning the optics of the 9110 It provides a current indication of the laser level relative to when it was measured at the factory 100 is the factory level It also allows you to turn the pump on and off Software 1 The TrakPro Lite Secure Data Transfer utility and user manuals come on a CD that was packaged with you...

Reviews: