AEROTRAK

®

 

PORTABLE AIRBORNE 

PARTICLE COUNTER 

MODEL 9110 

 
 

QUICK START GUIDE 

 
 
 

P/N 6004346, REVISION K 

MARCH 2018 

 
 
 
 
 

 

Summary of Contents for AeroTrak 9110 Series

Page 1: ...AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE P N 6004346 REVISION K MARCH 2018 ...

Page 2: ... controls adjustments or procedures other than those specified in this manual may result in exposure to hazardous optical radiation C A U T I O N The shipping containers and packaging provided with your particle counter are specially designed to protect the instrument Please retain the packaging for shipping the instrument for service or calibration Use of other packaging may result in damage to t...

Page 3: ...hat is not a clean room This will prevent contaminating the optics that will then require cleaning Note For zero checking in a dirty environment two filters in series may be needed 2 Remove the battery door in the back of the instrument see picture below with the two thumb screws and install one or more batteries doesn t matter which slot 3 Connect the appropriate power cord to the universal power...

Page 4: ... particle counter including data display system configuration device sampling and Recipes 8 Use the Data screen to review data that has been collected 9 Use the Reports screen to select various standard reports for viewing and printing 10 The screens and their options are explained in detail in the Operation Manual Using the Onscreen Keyboard 1 Throughout the setup screens a keyboard will appear o...

Page 5: ...rganization used by the supported classification standards where a zone or room is classified by measuring samples at various locations within that zone If the instrument is not being used for standard classification it is still a good practice to group sample data by Zone because it is easier to select the grouped data for printing and export and it helps to annotate exported sample data by relat...

Page 6: ...mber of samples for each data collection period is chosen Channels allow for channels to be enabled disabled and alarm levels to be chosen 9 Timing field details are provided below Field Description Start Delay Start Delay indicates how long it will be before the first sample is taken NOTE It takes approximately 10 seconds for the pump to reach the flow set point taking a measurement before the pu...

Page 7: ...le Duration of the sampling period Vol Volume of air that was sampled Alarm Alarm threshold was triggered Yes or not No Inst Status of the instrument hardware OK if no issues or an error abbreviation if instrument has a possible issue Temp Temperature at the end of the time the data was collected if optional probe was connected during sampling Data Screen Labels and Controls Field Description RH H...

Page 8: ...USB IP address and date and time format Service Screen This screen is for use when cleaning the optics of the 9110 It provides a current indication of the laser level relative to when it was measured at the factory 100 is the factory level It also allows you to turn the pump on and off Software 1 The TrakPro Lite Secure Data Transfer utility and user manuals come on a CD that was packaged with you...