TSI Incorporated velocicalc 9545 Operation And Service Manual Download Page 2

 

Copyright

©

 

TSI Incorporated / May 2007 / All rights reserved. 

Address 

TSI Incorporated / 500 Cardigan Road / Shoreview, MN  55126 / USA 

Fax No. 

(651) 490-3824 

LIMITATION OF WARRANTY AND LIABILITY 

(effective July 2000)

 

Seller warrants the goods sold hereunder, under normal use and service as described in the 
operator's manual, shall be free from defects in workmanship and material for twenty-four (24) 
months, or the length of time specified in the operator's manual, from the date of shipment to the 
customer. This warranty period is inclusive of any statutory warranty. This limited warranty is 
subject to the following exclusions: 
a. 

Hot-wire or hot-film sensors used with research anemometers, and certain other 
components when indicated in specifications, are warranted for 90 days from the date of 
shipment. 

b. 

Parts repaired or replaced as a result of repair services are warranted to be free from 
defects in workmanship and material, under normal use, for 90 days from the date of 
shipment. 

c. 

Seller does not provide any warranty on finished goods manufactured by others or on any 
fuses, batteries or other consumable materials. Only the original manufacturer's warranty 
applies. 

d. 

Unless specifically authorized in a separate writing by Seller, Seller makes no warranty 
with respect to, and shall have no liability in connection with, goods which are 
incorporated into other products or equipment, or which are modified by any person other 
than Seller.  

The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated 
herein. 

NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR 

PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE

TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR 
BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, 
INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED 
ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL 
BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE 
PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE 
GOODS. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, 
CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE 
RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS 
OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 
months after a cause of action has accrued. The goods returned under warranty to Seller's 
factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. 
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND 
LIABILITY, which contains the complete and exclusive limited warranty of Seller. This 
LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms 
waived, except by writing signed by an Officer of Seller. 

Service Policy 

Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our 
customers, our service policy is designed to give prompt attention to any problems. If any 
malfunction is discovered, please contact your nearest sales office or representative, or call 
Customer Service department at (800) 874-2811 (USA) or (1) 651-490-2811 (International). 

 

Summary of Contents for velocicalc 9545

Page 1: ...Ventilation Testing VELOCICALC Air Velocity Meter Models 9545 9545 A Operation and Service Manual ENERGY AND COMFORT ...

Page 2: ...rranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE TO THE EXTENT PERMITTED BY LAW THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE LIMIT OF SELLER S LIABILITY FOR ANY AND ALL LOSSES INJURIES OR DAMAGES CONCERNING THE GOODS INCLUDING CLAIMS BASED ON CONTRACT NEGLIGENCE TORT STRICT LIABILITY OR O...

Page 3: ...nding the Probe 3 Retracting the Probe 3 Connecting to a Computer 4 CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 SETTINGS 6 FLOW SET UP 6 ACTUAL STANDARD SETUP 6 DATA LOGGING 7 Measurements 7 Log Mode Log Settings 7 Delete Data 7 Memory 7 LogDat2 Downloading Software 7 CHAPTER 4 MAINTENANCE 9 Recalibration 9 Cases 9 Storage 9 CHAPTER 5 TROUBLESHOOTING 11 APPENDIX...

Page 4: ......

Page 5: ...pack the instrument and accessories from the shipping container Check the individual parts against the list of components below If anything is missing or damaged notify TSI immediately 1 Carrying case 2 Instrument 3 USB cable 4 CD ROM with downloading software ...

Page 6: ......

Page 7: ... adapter The AC adapter will not recharge the batteries Using the Telescoping Probe The telescoping probe contains the velocity temperature and humidity sensors When using the probe make sure the sensor window is fully exposed and the orientation dimple is facing upstream NOTE For temperature and humidity measurements make sure that at least 3 inches 7 5 cm of the probe is in the flow to allow the...

Page 8: ... labeled COMPUTER to the computer USB port and the other end to the data port of the Model 9545 9545 A For more information on how to download stored data see Chapter 3 section titled LogDat2 Downloading Software Caution This symbol is used to indicate that the data port of the Model 9545 9545 A is not intended for connection to a public telecommunications network Connect the USB data port only to...

Page 9: ... terms that are used in different places The following is a brief explanation of the meanings of those terms Sample Consists of all of the measurement parameters stored at the same time Test ID A group of samples The statistics average minimum maximum and count are calculated for each test ID The maximum number of test IDs is 100 Time Constant The time constant is an averaging period It is used to...

Page 10: ...n Flow Setup mode there are 4 types Round Duct Rectangle Duct Duct Area and Horn Use the g or h soft keys to scroll through the types and then press the key to accept the desired type To change the value highlight the Enter Settings option and press the key Use the instructions below to change the value of the type that you selected NOTE The horn numbers are the models of the horns For example 100...

Page 11: ... This option displays the memory available Delete All under Delete Data will clear memory and reset the memory available LogDat2 Downloading Software The Model 9545 9545 A comes with special software called LogDat2 Downloading Software which is designed to provide you with maximum flexibility and power To install this software on your computer follow the instructions on the label of the LogDat2 CD...

Page 12: ......

Page 13: ...4 The Model 9545 9545 A can also be recalibrated in the field using the CALIBRATION menu These field adjustments are intended to make minor changes in calibration to match a user s calibration standards The field adjustment is NOT intended as a complete calibration capability For complete multiple point calibration and certification the instrument must be returned to the factory Cases If the instr...

Page 14: ......

Page 15: ...Switch unit on Low or dead batteries Replace batteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent section or use longer time constant Instrument Error message appears Memory is full Download data if desired then DELETE ALL memory Fault in instrument Factory service required on inst...

Page 16: ......

Page 17: ... Resolution 0 1 F 0 1 C Relative Humidity from Velocity Probe Range 0 to 95 RH Accuracy4 3 RH Resolution 0 1 RH Wet Bulb Temperature from Velocity Probe Range 40 to 140 F 5 to 60 C Resolution 0 1 F 0 1 C Instrument Temperature Range Operating Electronics 40 to 113 F 5 to 45 C Operating Probe 14 to 140 F 10 to 60 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Altitude up to 4000 me...

Page 18: ...ight Weight with batteries 0 6 lbs 0 27 kg Power Requirements Four AA size batteries included or AC adapter optional 9 VDC 300 mA 4 18 watts input voltage and frequency vary depending on which adapter is used 1 Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C 2 The accuracy statement of 3 0 of reading or 3 ft min 0 015 m s whichever is greater begins at 30 ft min thro...

Page 19: ...si com Website www tsiinc fr Germany Tel 49 241 523030 E mail tsigmbh tsi com Website www tsiinc de Sweden Tel 46 8 595 13230 E mail tsiab tsi com Website www tsi se India Tel 91 80 41132470 E mail tsi india tsi com China Tel 86 10 8260 1595 E mail tsibeijing tsi com Contact your local TSI Distributor or visit our website www tsi com for more detailed specifications P N 1980564 Rev B Copyright 200...