Page 1: ...TN Crane Scales V1 13 V1 10 08 18 2020 ...

Page 2: ...hing on off 7 5 2 Zeroing 7 5 3 Using Tare 7 5 4 Select Weighing Units 7 5 5 Overload Warning 7 5 6 Sleep Mode 8 5 7 Auto Power Off Setting 8 5 8 Back Light Setting 8 5 9 Remote Controller 8 5 10 Overload Records 9 5 11 Bluetooth Operation optional 9 5 12 APP Software Operation In Android Mobile Operating System optional 10 5 13 WIFI Operation optional 14 6 PARAMETERS 17 6 1 PARAMETER SETTING 17 6...

Page 3: ...TN M Series Crane Scales Technical Manual 12 HANDLING INSTRUCTIONS 27 ...

Page 4: ...d weighing of freely movable loads Do not stand or go under suspended loads Do not use on building site Keep an eye on suspended Do not exceed nominal load of crane scales Do not install the scale in direct sunlight Verify the local voltage and receptacle type are correct for the scale Only use original adaptor other could cause damage to the scale Pluggable equipment must be installed near an eas...

Page 5: ... overhead weighing applications 30mm digits LCD display with LED back light Rechargeable Li battery operation Sleep function With remote controller for controlling easy to operate IP65 waterproof technology 2 2 Overview 1 Loop 2 Weight display 3 Keyboard 4 Load housing 5 Safety bracket 6 Hook 1 2 3 4 5 6 7 8 9 10 7 Battery cover 8 AC adapter jack 9 Antenna 10 Controller keyboard ...

Page 6: ...vertical load 3 3 Power Connection Connect the adaptor pin in to the indicator adaptor jack Adaptor jack is locating below the scale Adaptor connects into your AC power socket Plugable equipment must be installed near an easily accessible socket outlet with a protective ground earth contact 3 4 Rechargeable battery operation Note Please charge the battery before using the scale for the first time ...

Page 7: ...the LED display Yellow The battery is being charged Red The battery is nearly discharged Green Rechargeable battery is completely charged 3 4 2 Battery maintenance Do not use any other type of power adaptor than the one supplied with the scale Recharge battery should be changed in every three months when not in use If the scale is not used for an extended period of time remove the battery from the...

Page 8: ...charging status Bluetooth or WIFI indicator Indicates scale is in Bluetooth or WIFI communication mode the indicator depends on the option selected in sub menu Keys Description ON OFF ON OFF key turn the scale on off ZERO 1 Zero key Used to clear and zero the display 2 Enter key Used to enter the selected menu sub menu and setting TARE 1 Tare key Used to perform a tare function Subtracts weights 2...

Page 9: ...TN M series crane scale technical manual 6 4 3 Remote controller Key 1 For using shift gross and net weight Key 2 For using enter sleep mode Key 3 For using enter Zero Key 4 For using tare ...

Page 10: ...ighing the net weight of the object being weighed is always displayed Taring a container Load weight on the hook Press TARE key Zero is displayed and tare is subtracted And NET indicator will be on Remove weight from the hook Tared weight is displayed It can set only one tare value It will be shown with a minus value Press G N to change between gross weight and net weight Clearing tare To clear th...

Page 11: ...ll not be available 5 9 Remote Controller TN series crane scale can order remote controlled you can find 4 keys at the remote controller the function is same with the crane scale except ON OFF key Please pull out the antenna before operate the remote controller The remote controller operate distance is around 20m but it s depends on the operate environment The red LED must light up when any button...

Page 12: ...cords 5 10 2 1 Delete the single overload record Turn on the scale press ZERO key during self checking and then display will be come to the normal weighing mode Press and hold G N key for 2 seconds the overload number will appear Press TARE key to select the records number to be delete Press ZERO key to delete the overload record you select and the display will be show delete words 2 seconds later...

Page 13: ...the display will be on 5 12 APP Software Operation In Android Mobile Operating System optional File Name app release apk Operating System support Android 4 4 or above 5 12 1 Install TN APP software in your android smart phone 1 Click the TA100M icon to run the App 2 A prompt to enable Bluetooth will be pop up 3 Touch ALLOW key to turn Bluetooth on in your mobile 4 The Bluetooth indicator will be o...

Page 14: ...crane scale 6 If using in the first time it need to search the device to pair with your mobile phone the Bluetooth name is consist of 4 Alphanumeric characters it is marked on the Bluetooth model if necessary you can open the housing to check 7 Select the device to pair it may be asked to input the password the default password is 1234 ...

Page 15: ...ect the scale to start to use Reserved key Sleep mode key Used to enter sleep mode in normal weighing mode Used to clear the accumulation memory Used to add the value to the accumulation memory Note The accumulation memory is not to be regarded as an approved weighing result 5 12 3 Weighing Operation 1 Before do weighing operation touch key to connect with scale to use 2 Once connected successfull...

Page 16: ... The weighing records will be show 8 Tab each weighing record can see the detail weighing data for the product 9 Tab key the weighing record can be sent to PC via E mail or other chat tools in csv file 8 Tab key the weighing record will be cleared ...

Page 17: ...ommunication F5 com mode WIFI on F5 com BAUD 9600 Scale should be in the allowed limits of the distance 10 meters to connect WIFI If connected with WIFI successfully the WIFI indicator in the display will be on 2 Search the new WIFI network named Doit_WiFi_xxxxxx in the computer 3 There is no need to input password click the new WIFI network to connect directly 4 Input the IP address http 192 168 ...

Page 18: ...outer name from the SSID list and input the wireless router password 7 Assign IP address of the scale Note The IP address of scale and wireless router should be in the same network 8 Click save key to confirm 9 Select MORE Restart option to restart the WIFI and click Return to confirm If finish the configuration you can start to test the WIFI communication ...

Page 19: ...e Hyper Terminal in computer 11 Create a new connection and enter a name for the connection 12 Enter the host address and port number The host address is the IP address of scale The default port number is 9000 13 Click OK key the weighing data will be show ...

Page 20: ...ive digit Press TARE key to increment a digit Press ZERO key to confirm display will shows F0 cal scale enter setting mode Enter the Selected Menu Press ZERO key it can confirm which will be shown displayed Select the Menu Press TARE key it can choose menu block one by one Escape from the Menu Press G N key to escape from the setting menu To access the technical parameters it s required to press t...

Page 21: ...able WIFI communication OF To disable WIFI communication Off Communication port function off baud 600 Baud rate selection 1200 2400 4800 9600 F6 TI 00 00 Set time F7 DA 00 00 00 Set date F8 ST on Multi tare function on off Multi tare function on F9 OF Set automatic turn off the scale 0 Auto off function disable 5 Scale will be auto off 5 minutes later 10 Scale will be auto off 10 minutes later 20 ...

Page 22: ...ey to enter calibration display shows Unload 9 Empty the hook when the indicator above STABLE appears press ZERO key to confirm display will show calibration weight value 10 You can change this weight value using SLEEP key to clear the active digits using G N key to move the active digit right using TARE key to increment a digit 11 Press ZERO key to confirm 12 Display show LOAD add calibrate mass ...

Page 23: ...clear G g N n Net gross weight shift 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 S Z G 20 K G T K G CR LF U Z N T T T CR LF No Description 1 Weighing data status stable or unstable 2 Sleep mode status 3 Weight Gross Net 4 Negative or Positive if the data is positive the first byte is instead of space 5 10 6 bits Weight including decimal point space will be filled in when the wei...

Page 24: ...IFI Bluetooth Operation Temperature 10 C 40 C Power Input AC100 240v 50 60Hz Out put DC 12V 2500mAh Standard rechargeable Battery 7 4V 5200mAh Battery Name Li ion Battery Battery Mode 18650 2S2P 5200mAh 7 4V Battery Cell 18650 2600mAh 3 7V Battery Shelf Period 1 year Battery life Approx 60 Hours with backlight Approx 72 Hours without backlight Remote Controller Alkaline Battery 12V 23A Dimension W...

Page 25: ...2 4 Open Voltage 7 6V 8 2V 2 5 Load Voltage 7 4V 10Ω 2 6 Internal Impedance 250mΩ AC 1KHz after standard charge 2 7 Charge voltage 8 4V 2 8 Standard charge current 2600mA 0 5C 2 9 Max charge current 2600mA 0 5C 2 10 Standard discharge current 1040mA 0 2C 2 11 Max discharge current 2600mA 0 5C 2 12 Discharge cut off voltage 5 5V 2 13 Operating Temperature 0 45 Charge 20 60 Discharge 2 14 Storage Te...

Page 26: ...201 B 160 160 160 160 160 C 128 5 128 5 128 5 128 5 128 5 D 80 80 80 95 95 E 60 60 60 80 80 F 270 270 275 320 330 G 219 219 219 5 248 247 5 H Φ19 Φ19 Φ22 Φ25 4 Φ31 8 J Φ50 8 Φ50 8 Φ58 Φ68 3 Φ82 5 L Φ23 Φ23 Φ26 5 Φ30 Φ36 M Φ23 Φ23 Φ26 5 Φ30 Φ36 N 415 415 456 528 557 P 477 477 532 624 660 Q 42 9 42 9 50 8 63 5 63 5 ...

Page 27: ...platform empty ol Over range Remove the load Re calibrate LO BAT Low battery indicator Please charge the battery Fail Calibration Error Check the test weights Re calibrate Err 17 Tare out of range Minus weight or overload Remove the load and restart scale again Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors ...

Page 28: ...EC 1 Overlay 1 2 Front cover 1 AL 3 Main board 1 4 round screw 4 Carbon Steel M3 8 5 Seal ring 1 NBR 6 Rear cover 1 ABS 7 Waterproof gland 3 M10 8 Spring Washer 2 Carbon Steel M8 9 Internal hexagon screw 2 Carbon Steel M8 40 10 Load cell 600kg 1 5t 3t 1 11 Round pin 1 Carbon Steel 12 Back cover 1 AL ...

Page 29: ...teel M4 8 17 Internal hexagon screw 4 Carbon Steel M6 55 18 Cabel gland 2 PE 19 Adaptor plug 1 20 Adaptor socket 1 21 Washer 1 SUS304 22 Hook 1 Carbon steel 23 screw 2 Carbon steel M4 10 24 Hexagon screw 2 Carbon steel M4 10 25 Seal washer 1 NBR 26 Seal washer cover 1 SUS304 27 Calibration switch 1 28 Overlay 1 29 M6 Mental Button 5 ...

Page 30: ...ontainer Do not use the battery in combination with primary batteries such as dry cell batteries or batteries of different Capacity type or brand Do not use the battery if it gives off an odor generates heat becomes discolored or deformed or appears abnormal in any way If the battery is in use or being recharged remove it from the device or charger immediately and discontinue use Caution Do not us...

Page 31: ...ide sales marketing and service of electronic weighing instruments The TSCALE products Medical Scale Counting Scale Tabletop Scale Retail Scale Precision Scale Platform Scale Weighing Indicator Crane Scale Floor and Pallet Scale Accessory Software TSCALE has its manufacturing unit in Kunshan China ISO 9001 certified company OEM ODM partner more than 20 products have OIML certifications from Hollan...