TScale JC 15 User Manual Download Page 1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

UGJC-E1.00

JC 

series

Dual counting Scales

User’s guide

Summary of Contents for JC 15

Page 1: ...UGJC E1 00 JC series Dual counting Scales User s guide ...

Page 2: ......

Page 3: ...JC series dual counting scale user s guide i ...

Page 4: ... the remote scale 4 3 2 3 Remote scale connection 4 3 2 4 Remote scale setup 4 SECTION4 KEY DESCRIPTIONS 6 SECTION5 DISPLAYS 7 5 1 WEIGHT WINDOW 7 5 2 UNIT WEIGHT WINDOW 7 5 3 COUNT WINDOW 7 SECTION6 OPERATION 8 6 1 ZEROING AND TARING THE DISPLAY 8 6 1 1 Zeroing 8 6 1 2 Taring 9 6 1 3 Taring the remote scale 9 6 2 MEMORY FUNCTIONS 10 6 2 1 Manual accumulation 10 6 2 2 Automatic accumulated total 1...

Page 5: ... Storing PLU s manually 13 6 4 2 Entering description manually 14 6 4 3 Recalling PLU s manually 14 SECTION7 PARAMETERS 16 7 1 USER PARAMETERS 16 7 2 USER PARAMETERS SETTING TABLE 16 SECTION8 BATTERY OPERATION 18 SECTION9 RS 232 OUTPUT 19 SECTION10 CALIBRATION 20 SECTION11 ERROR CODES 21 SECTION12 TECHNICAL PARAMETERS 22 ...

Page 6: ......

Page 7: ... using either pounds only kilograms only or can be switched between pounds and kilograms All have stainless steel weighing pan All the keypads are sealed color coded membrane switches and the displays are large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight All units include automatic zero tracking audible alarm for pre set weights pre set tare and an accumul...

Page 8: ...m minimum 4 X 350 ohm load cells Connection 4 wire connection to load cells plus shield Maximum cable length 6 meters Termination 9 pin d subminiature plug on scale 2 3 COMMON SPECIFICATIONS Interface Bi directional RS 232 Interface Stabilisation Time 2 Seconds Operating Temperature 0 C 40 C 32 F 104 F Power supply 9 VDC 800 mA from external power supply Calibration Automatic external Display 3 x ...

Page 9: ...ensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scales clean Do not stack material on the scales when they are not in use 3 2 SETTING UP THE SCALES 3 2 1 SETTING UP THE LOCAL SCALE The JC Series comes with a stainless steel platform packed sep...

Page 10: ... bubble is in the center Press Local Rem key and test weighing performance 3 2 3 REMOTE SCALE CONNECTION The cable for the load cell goes to a 9 pin d subminiature plug connector with the following connections Pin numbers Connection Pins 1 2 Excitation 5V Pins 4 5 Excitation 0v Pin 7 Signal Pin 8 Signal The sense wires connections of a six wire load cell are not used but can be connected to the re...

Page 11: ...ould be reduced to give a good number of ADC counts per displayed division for example set to 1 5000 or 1000kg x 0 2kg Setting a high resolution without providing a good input to the remote scale ADC will not give better accuracy and may make the scale difficult to meet performance specification For best performance ensure a minimum of 0 1uV d ...

Page 12: ... the number of items of a sample M1 M5 Direct PLU key To store and recall the Piece Look Up sample information quickly PLU To store and recall the Piece Look Up sample information 100 PLUs with description unit tare weight U Wt Units This key is used to enter the weight of a sample manually It will also change the weighing units when other units are enabled PST To set the upper limit for the numbe...

Page 13: ...mine an accurate count the arrow will show at U Wt When a value has been entered into the memory the arrow above M will be on In both the cases the scale continues to operate and the indicators are to alert the user of a potential problem 5 3 COUNT WINDOW This display will show the number of items on the scale or the value of the accumulated count See the OPERATION section An arrow above the symbo...

Page 14: ...f letters are shown later The switch from local scale to remote scale should be possible at any time by pressing the Local Rem key or if the user enables the function it can happen anytime the weight on the remote scale changes from negative value or zero to a positive value greater than 50d NOTE For frequently used items counting is made easier by using PLU numbers Product Look Up Up to 100 PLU s...

Page 15: ... The zero indicator will also be ON because the platform is back to the same condition as it was when the Zero key was last pressed Second method of entering a tare value This method allows you to enter a value for the tare weight from the keypad This is useful if all containers are the same or if the container is already full but the net weight is required and the weight of the container is known...

Page 16: ...2 Automatic accumulated total The scale can be set to automatically accumulate total when a weight is placed on the scale This eliminates the need to press the M key to store values into the memory However the M key is still active and can be pressed to store the values immediately In this case the values will not be stored when the scale returns to zero See PARAMETERS Section on enabling Automati...

Page 17: ...t display will revert to the previous value otherwise it will show the new value that has been entered The sample is then added to the scale and the weight will be displayed as well as the quantity based upon the unit weight When weighing in kilograms the unit weight is shown in grams When weighing in pounds the unit weight is shown in pounds After the unit weight has been determined or entered th...

Page 18: ... with limits set Clearing of either or both the limits is allowed Both limits cleared will disable the Preset altogether If Preset Weight was selected the first display would show Hi net and lo net The beeper will work as described in the Beeper Parameter 6 4 PLU Product Look Up Product Look Up PLU numbers are used to store information about the commonly used items The Tare Weight Description of t...

Page 19: ...le for setting up PLU 27 with Description as M4 Nut and Unit weight of 0 015 DISPLAYS ACTIONS Weight Unit weight Count REMARKS Press PLU PLU Press 2 7 PLU 27 Press Pst PLU 27 x x x x x x x x x The current description will be shown with the first character flashing The flashing digit can be changed using the numeric keypad Pressing the CE key when the first character is flashing will clear all the ...

Page 20: ...oll through all the characters The numbers and characters are 1 2 A B C 3 D E F 4 G H I 5 J K L 6 M N O 7 P Q R S 8 T U V 9 W X Y Z 0 _ Where _ is a Space Not underscore The limitations of the 7 segment display sometimes make it difficult to display some letters The characters and the displayed symbols are A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T ...

Page 21: ... example if the local scale is selected whereas the tare value applies to the remote scale this would exceed the capacity of the local scale the Weight display would show zero tare weight If the tare value stored does not match the increment of the selected scale For example storing 1 446 for a scale with d 0 05 then round the tare weight depending on the scale resolution For example in this case ...

Page 22: ...se the desired setting and thereby go back to the sub parameter press the Tare key To return to the parameter press the Zero key 7 2 PARAMETER SETTING TABLE PARAMETER SUB PARAMETER DISPLAYS AND SETTINGS bEEP oFF Beeper is set to off bEEP on I n Beeper is set to on between limits bEEP bEEP on oUt Beeper is set to on outside limits when weight less than min capacity checkweighing function will not a...

Page 23: ...s no parity 7 data bits even parity 7 data bits odd parity ptype tpup lp50 Tpup TSCALE Tpup printer Lp50 TSCALE lp 50 printer U id U id Abc234 Shows the current user ID if any Enter a new User ID as described in the description under the PLU section The ID can be alphanumeric but is limited to 6 characters SC id Sc id Abc234 Shows the current scale ID if any Enter a new Scale ID as described in th...

Page 24: ...ll operate for about 10 hours after which it will automatically switch off to protect the battery To charge the battery simply plug into the mains power The scale need not to be turned on The battery should be charged for 12 hours for full capacity Just under the Count display is an LED to indicate the status of battery charging When the scale is plugged into the main power the internal battery wi...

Page 25: ...CII code 4800 Baud 600 9600 selectable 8 data bits 8 data bits no parity 7 data bits even and odd parity selectable No Parity Connector style needed 25 pin d subminiature socket Pin 2 Output Pin 3 Input Pin 7 Signal Ground Sample of output LOCAL SCALE ID 123ABC NAME Text 12 456 kg NET 1 1234 g U W 11 PCS TOTAL 49 824 kg TW 44 TPC 4 No ...

Page 26: ... LocAL tEch rEmo tE Use the Smpl to select the weighing unit to be used for setting the calibration for the scale The arrow in the Weight window will indicate the unit selected Press the Tare key to continue tEch Uni t You will enter Calibration Display will ask to unload any weight on the platform After STABLE indicator on Press the Tare key to continue Un L o Ad Enter the calibration weight to b...

Page 27: ...IPTION POSSIBLE CAUSES Err 4 Initial Zero is greater than the permissible value typically 4 of maximum capacity when power is turned on or when the Zero key I s pressed Weight on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 5 Keyboard error Improper operation of the scale Err 6 A D c...

Page 28: ...u to enter the password Pin Default Password is9999 Enter 9 four times Press Tare Pin Select the scale to be set up by using the Local Rem key Press the Tare to enter the technical section for that scale tEch LocAL tEch rEmotE Use the Smpl to select the weighing unit to be used for setting up the parameters for the scale The arrow in the Weight window will indicate the unit selected Press the Tare...

Page 29: ...5d 1d 2 4 d Press the Smpl to go to next menu use Tare key to enter Use Smpl to increment the values then Tare 0 Auto Zero auto range at power on Select form 0 2 5 10 or 20 Press the Smpl to go to next menu use Tare key to enter Use Smpl to increment the values then Tare 0 manl Zero manual range Select form 0 2 2 4 10 50 or 100 Press the Smpl to go to next menu use Tare key to enter Enter the new ...

Page 30: ...E and their distributors offer a full range of technical services such as on site and workshop repair preventative maintenance and calibration facilities TAIWAN SCALE operates an approved quality management system and is certified to ISO9001 2000 Visit our Website at www taiwanscale com Taiwan Scale Mfg Co Ltd 282 Sec 3 Hoping W Rd Taipei Taiwan TEL 886 2 23068203 FAX 886 2 23044354 e mail tscale ...