6. PARAMETERS
To set parameter, you should short K2 jumper, then turn on the scale.
Press
key during the self checking.
Display will be show
pn
Press
,
and
to enter, display will be show
po chk
Menu
Sub Menu
Description
P 0 chk Set H
Set high limits for check weighing
Set lo
Set low limits for check weighing
beep
No
No beep for check weighing
Ok
Beep, when check weighing between the
limits
ng
Beep, when check weighing out of the limits
P 1 com
Mode
This option is used to set accumulation
and RS-232 communication
Options:
Cont
: data send continues
St 1
: Send data one time, when stable.
St c
: Send data continuously, when
stable
P r1
: Send data one time, when press
print
Key (in printer mode)
Pr 2
: Send data to print and
accumulation,
When press
.key
Auto
: Auto accumulate and auto print
mode.
When weight stable and return to
zero.
Ask
: Ask mode,
Command R: read data
Command T: Tare
Command Z: Zero
Wireles
: Wireless mode (communication
through wireless)
Baud
To set the baud rate.
Options:
600
/
1200
/
2400
/
4800
/
9600