5
ELECTRICAL CONNECTIO
ELECTRICAL CONNECTIO
ELECTRICAL CONNECTIO
ELECTRICAL CONNECTIO NS
NS
NS
NS
T E R M I N A L B O A R D D E S C R
T E R M I N A L B O A R D D E S C R
T E R M I N A L B O A R D D E S C R
T E R M I N A L B O A R D D E S C R I P T I O N
I P T I O N
I P T I O N
I P T I O N
1
CH A
Encoder input: A channel
2
CH B
Not used
3
CH Z
Not used
4
ABL
Not used
5
+
Positive supply for encoder
6
-
Negative supply for encoder
7
COM
Outputs common
8
OUT 1 Output 1: first active threshold
9
OUT 2 Output 2: second active threshold
13
VAC
Power supply
14
VAC
Power suppply
Digital inputs
Opto-insulation
2500 V rms
Load current
10 mA
Impedance
1 kOhm
Polarization
NPN
0 logic state voltage
0V + 6V
1 logic state voltage
10V + 12V
Digital outputs
Opto-insulation
2500 V rms
Commutable load
AC-DC
(NPN-PNP)
Maximum operating
tension
40 Vac/dc
Maximum current
500 mA
Connect only one conductor for each terminal and be sure that the power supply is as indicated on the back of the
device; use only cables properly insulated for operating tensions and temperature; keep power cables separated from
control cables.
Be very careful when connecting the device and follow the indications provided in the following diagram. Be sure that
the device is not connected to the power supply when carrying out all the electrical connections.
If the malfunction of this device may injures persons or damage things, it is stricly recommended to
install mechanical devices or protections to guarantee safety!