Troubleshooting
Spreader SP-100
SPREADER
DOESN'T RUN
FIX OR REPLACE
AGITATOR
INTERFERENCE
FUSE
BLOWN
JAMED AGITATOR
MATERIAL
ISSUE
BAD MOTOR
CHECK WITH TEST KIT
TEST GOOD
NO LOAD
4-20 AMPS
BAD MOTOR/TRANS
ASSEMBLY
TOO MUCH
AMP DRAWN
TEST BAD
20+ AMPS
BAD TRANSMISSION
CHECK WITH TEST KIT
TEST TURN SHAFT
BY HAND SHOULD
TURN FREELY
CORROSION AT
CONNECTION
CLEAN OR REPLACE
DON'T FORGET
USE DIELECTRIC
GREASE
DON'T FORGET
USE DIELECTRIC
GREASE
BAD ELECTRICAL
CONNECTION
LOOSE CONNECTION
TIGHTEN OR REPLACE
REPLACE WIRING
DEAD SHORT
IN WIRING
BAD MOTOR
CHECK WITH TEST KIT
ELECTRICAL
CONNECTION
TEST DIRECT POWER
(12 VOLTS) TO MOTOR
CHECK
SWITCH
LOOSE OR
UNPLUGGED
CORROSION
CHECK BATTERY
LOAD TEST
GATE WON'T OPEN
RECONNECT OR
REPLACE CABLE
MATERIAL WILL
NOT FLOW
MATERIAL
ISSUE