Calibration
Calibration adjustment is permanent and should
only be performed using accurate calibration
weights that match the requirements for your
scale (see the chart on back).
Do not use coins or other
household items to calibrate.
1.
Flip the slide switch on the
underside of the scale to the
“Calibration” position.
2.
Prepare the required weight for
your scale. (see chart on back)
3.
Find a flat and level surface to perform calibration
and let the scale adjust to room temperature.
4.
Press
ON/OFF
to turn the scale on and wait for the
scale to stabilize.
5.
Press and hold the
MODE
key until the display
shows ‘CAL’.
6.
Make sure nothing is on the platform then press
MODE
to confirm the zero point.
7.
The display will then flash the required calibration
weight.
8.
Place the required calibration weight on the center
of the platform.
9.
The display will show ‘PASS’ then return to weighing
mode. You may now return the slide switch to
“Auto-Off Enabled” or “Auto-Off Disabled”.
Auto-Off Setting
The Auto-Off setting can be disabled by setting the
slide
switch on the underside of the scale to the “Auto-Off
Disabled” position. If set to “Auto-Off Enabled”, the scale
will turn off after 180 sec. of inactivity.
Radio Frequency
Interference
Unlevel Surfaces
High Humidity
Air Currents
Vibration
Extreme Temps
HOLD
ON/OFF
MODE
TARE
Auto-Off
Enabled
(180 sec)
Calibration
Auto-Off
Disabled
Radio Frequency
Interference
Unlevel Surfaces
High Humidity
Air Currents
Vibration
Extreme Temps
HOLD
ON/OFF
MODE
TARE
Auto-Off
Enabled
(180 sec)
Calibration
Auto-Off
Disabled
Radio Frequency
Interference
Unlevel Surfaces
High Humidity
Air Currents
Vibration
Extreme Temps
HOLD
ON/OFF
MODE
TARE
Auto-Off
Enabled
(180 sec)
Calibration
Auto-Off
Disabled