Truvox International OB38200 User Instructions Download Page 6

  Operators  should  be  physically  capable  to 

manoeuvre, 

transport 

and 

operate 

the 

machine. 

  Operators should be able to recognise unusual 

operation  of  the  machine  and  report  any 
problems. 

  Only use the machine on firm level surfaces. 

  Wear suitable footwear to avoid slipping. 

  Wear suitable clothing to keep dry and warm.  

  Where  possible  implement  job  rotation  and 

adequate  rest  periods  to  avoid  continuous  use 
of the same muscles. 

  Let the machine do the work. Grip the handle 

as lightly as possible. 

  Stand  with  feet  slightly  apart  to  maintain  good 

balance. Avoid twisting the body more than 45 
degrees. 

  Do not leave machine running unattended 

  Do not smoke when using the machine. 

  Do  not  put  any  objects  into  openings.    Do  not 

use  with  any  opening  blocked:  keep  free  of 
dust,  debris,  hair,  or  anything  that may  reduce 
air flow. 

 
WARNING

  This  machine  is  for  dry  use 

only. 

 

CAUTION

  -  This  machine  is  for  indoor 

use  only  and  should  not  be  used  or 
stored outdoors or in wet conditions. 

 

CAUTION

 - If it is suspected that there is 

hazardous  dust  or  flammable  materials 
stop  cleaning  the  area  immediately  and 
consult your superior. 

 

WARNING

  Only  use  accessories  and 

spare parts provided with the machine or 
those  approved  by  the  manufacturer.  
The use of other accessories may impair 
the safety of the machine. 

 

  Ensure  the  machine  is  switched  off  before 

adding or changing accessories. 

1.3  Transporting the machine 

CAUTION

  –  Incorrect  lifting  techniques 

may  result  in  personal  injury,  where 
applicable  do  not  lift  large  and  heavy 

machines without assistance.  We advise that the 
manual handling regulations are followed. 
Please  refer  to  the  technical  table  for  details  on 
weight of machine. 
 
When  transporting  the  machine  ensure  that  all 
components,  tanks  and  removable  parts  are 
securely  fastened,  and  that  the  supply  cord  and 
plug are not trailing.  Detach hose and wand from 
machine where applicable. 
 
When transporting the machine the handle 
should be locked in the upright position. 
 

Take extreme care when moving the machine up 
or down steps or stairs. 
 

1.4  Symbols & Markings 

 
 

WARNING 

 
 
 

 

WARNING – READ THESE 

 

INSTRUCTIONS BEFORE 

 

USING MACHINE  

 
 
 
 
 
 

 

 

Earth symbol

 

 
 
 
 

Preparing for use 

2.1  Electrical connection 

Before  connecting  the  machine  to  the  power 
supply, 

check 

that 

your 

supply 

voltage 

corresponds with that marked on the rating label. 
 

The power  supply cord plus  any extension leads 
should  not  exceed  30m  in  total,  otherwise  you 
may  experience  problems  starting  up  the 
machine.  The  cross-section  of  any  extension 
cable wiring must be at least 2,5 mm

². 

 

Should  an  extension  cord  be  used,  ensure  cord 
rating is adequate for the equipment.  Do not use 
extension  cord  in  coiled  condition  as  this  could 
result in overheating of the cord. 
 

UK only 

The  supply  cord  for  230v  models  is  fitted  with  a 
plug  containing  a  13  amp  fuse.  Should  the  fuse 
require replacement it must only be replaced by a 
13 amp fuse conforming to BS1362, and the fuse 
cover must be refitted. If the fuse cover is lost the 
plug  must  not  be  used  until  the  correct 
replacement cover is fitted. 

 
IMPORTANT

  -  If  the  supply  cord  is  damaged,  it 

must only be replaced by a special cord available 
from  the  manufacturer  or  an  authorised  service 
agent. 

 

WARNING – THIS APPLIANCE MUST 
BE EARTHED 

Summary of Contents for OB38200

Page 1: ...tructions Orbis OB38200 OB38400 OB45200 OB45400 OB50200 OB50400 OBLP452 400 Rotary floor cleaning machines 03 6120 0000 Iss 2 03 10 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE ORIGINAL IN...

Page 2: ...2...

Page 3: ...6 Adjusting the handle height 7 7 Operation 7 7 1 Starting the machine 7 7 2 Polishing 8 7 3 Scrubbing and Shampooing 8 7 4 Fitting the solution tank 8 7 5 Removing the solution tank 8 7 6 The vacuum...

Page 4: ...4 Diagrams...

Page 5: ...oltage corresponds with the voltage shown on the rating plate All parts are to be positioned as indicated in the instructions before using the machine Do not operate the machine if it malfunctions or...

Page 6: ...machines without assistance We advise that the manual handling regulations are followed Please refer to the technical table for details on weight of machine When transporting the machine ensure that...

Page 7: ...d Drive plate Attachment point for brush or drive disc and pad Cable winder Used to hold supply cord in place on handle when machine is not in use Can be turned to enable quick release of cord Motor o...

Page 8: ...is complete unplug the machine from the power supply empty the solution tank and clean and dry the machine IMPORTANT Dispose of unused cleaning solution in accordance with the manufacturer s directio...

Page 9: ...aking maintenance operations or adjustments switch off machine and unplug from the electricity supply The machine requires minimum maintenance apart from the following checks by a trained operator Sup...

Page 10: ...r any of the following Periodic maintenance and repair or replacement of parts due to normal wear and tear 5 This guarantee is governed by the laws of England This guarantee does not cover any of the...

Page 11: ...Pressure g cm 28 22 18 27 28 22 18 27 Speed rpm 190 190 190 190 380 380 380 Lo hi speed Motor ac induction Motor Rating W 1100 1100 1100 1100 1100 1100 1100 1100 Cable Length m 15 15 15 15 15 15 15 15...

Page 12: ...ly IMPORTANT Genuine accessories are only available from authorised Service Agents or Truvox Customer Services Department 15 Fault diagnosis WARNING Before undertaking maintenance operations or adjust...

Page 13: ...13...

Page 14: ...manufactured using the following transposed harmonised European Standards and technical specifications Ref No Title 2006 42 EC Machinery Directive and subsequent amendments 2006 95 EC The Low Voltage...

Page 15: ...15...

Page 16: ...16 Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com Authorised dealer...

Reviews: